Currently on the market there are numerous devices capable of measuring thicknesses of plastic film but which contain a high complexity and a high cost. The purpose of this Thesis was to design and realize a simple and economic device capable of measuring translucent plastic film, of a thickness varying from 15μm to 3 mm, using a Michelson interferometer powered by a low-coherence source. The first part of the work aims to the realization of a system of high voltage power supply adapted to feed the tool. Subsequently I've developed two versions of amplifiers, class A and D, used to drive a piezoelectric fiber stretcher. Finally, I've developed a firmware for the acquisition of the interferometric signal and a Virtual Interface using LabVIEW software. In conclusion, the tool has achieved satisfactory results and has proven reliable.

Attualmente sul mercato sono presenti numerosi dispositivi in grado di misurare spessori di film plastici ma che prevedono un'elevata complessità ed un alto costo. Lo scopo di questa Tesi è stato quello di progettare e realizzare uno strumento semplice ed economico in grado di misurare film plastici traslucidi, dello spessore variabile tra 15µm a 3 mm, mediante un interferometro di Michelson alimentato da una sorgente a bassa coerenza. La prima parte del lavoro mira alla realizzazione di un sistema di alimentazione ad alta tensione atta ad alimentare lo strumento. Successivamente si sono sviluppate due verisoni di amplificatori, in classe A e D, impieagati per pilotare un fiber stretcher piezoelettrico. Infine, è stato sviluppato un firmware per l'acquisizione del segnale interferometrico e una Virtual Interface tramite software LabVIEW. In conclusione, lo strumento ha raggiunto risultati soddisfacenti e si è dimostrato affidabile.

Misuratore ottico per film plastici sottili

VANNINI, LUCA
2013/2014

Abstract

Currently on the market there are numerous devices capable of measuring thicknesses of plastic film but which contain a high complexity and a high cost. The purpose of this Thesis was to design and realize a simple and economic device capable of measuring translucent plastic film, of a thickness varying from 15μm to 3 mm, using a Michelson interferometer powered by a low-coherence source. The first part of the work aims to the realization of a system of high voltage power supply adapted to feed the tool. Subsequently I've developed two versions of amplifiers, class A and D, used to drive a piezoelectric fiber stretcher. Finally, I've developed a firmware for the acquisition of the interferometric signal and a Virtual Interface using LabVIEW software. In conclusion, the tool has achieved satisfactory results and has proven reliable.
ING - Scuola di Ingegneria Industriale e dell'Informazione
18-dic-2014
2013/2014
Attualmente sul mercato sono presenti numerosi dispositivi in grado di misurare spessori di film plastici ma che prevedono un'elevata complessità ed un alto costo. Lo scopo di questa Tesi è stato quello di progettare e realizzare uno strumento semplice ed economico in grado di misurare film plastici traslucidi, dello spessore variabile tra 15µm a 3 mm, mediante un interferometro di Michelson alimentato da una sorgente a bassa coerenza. La prima parte del lavoro mira alla realizzazione di un sistema di alimentazione ad alta tensione atta ad alimentare lo strumento. Successivamente si sono sviluppate due verisoni di amplificatori, in classe A e D, impieagati per pilotare un fiber stretcher piezoelettrico. Infine, è stato sviluppato un firmware per l'acquisizione del segnale interferometrico e una Virtual Interface tramite software LabVIEW. In conclusione, lo strumento ha raggiunto risultati soddisfacenti e si è dimostrato affidabile.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2014_12_Vannini.pdf

non accessibile

Descrizione: Thesis text
Dimensione 5.8 MB
Formato Adobe PDF
5.8 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/102147