This thesis presents the work done on the project RELAB: “Monitoring of heat pumps systems”. A water-to-water heat pump is studied in details and a model is used to simulate its behaviour in steady state and partial load conditions. The results of the simulations are used to support the analysis of the monitored data. As for the monitoring systems, a careful study of the first available data has been done to verify the correct installation of the measuring devices. Some validation and elaboration filters have been created to prepare data for performance evaluations. The heat pump model has been implemented in MATLAB and it has been used to simulate the behaviour of the heat pump in partial load conditions. The results of the simulations have been used to study the data obtained in the monitoring process.

Nell’ambito di questa tesi viene presentato il lavoro svolto sul progetto RELAB: “Monitoraggio in campo di pompe di calore” e si approfondisce lo studio di un impianto con pompa di calore acqua-acqua presentando un modello di supporto all’analisi del suo funzionamento in condizioni stazionarie. Il contributo allo sviluppo del sistema di monitoraggio è partito dall’analisi dei dati monitorati per la verifica della corretta installazione dei misuratori e si è concentrato sull’implementazione di filtri di validazione e di elaborazione dei dati raccolti. Il modello della pompa di calore è stato implementato in MATLAB e simula il comportamento in condizioni stazionarie della macchina in funzionamento ai carichi parziali. Dai dati ottenuti dalle simulazioni è stato possibile interpretare in maniera più accurata i risultati del monitoraggio.

Monitoraggio in campo e modellizzazione di una pompa di calore a compressione di vapore acqua-acqua

CODELLA, FABRIZIO
2014/2015

Abstract

This thesis presents the work done on the project RELAB: “Monitoring of heat pumps systems”. A water-to-water heat pump is studied in details and a model is used to simulate its behaviour in steady state and partial load conditions. The results of the simulations are used to support the analysis of the monitored data. As for the monitoring systems, a careful study of the first available data has been done to verify the correct installation of the measuring devices. Some validation and elaboration filters have been created to prepare data for performance evaluations. The heat pump model has been implemented in MATLAB and it has been used to simulate the behaviour of the heat pump in partial load conditions. The results of the simulations have been used to study the data obtained in the monitoring process.
ING - Scuola di Ingegneria Industriale e dell'Informazione
28-lug-2015
2014/2015
Nell’ambito di questa tesi viene presentato il lavoro svolto sul progetto RELAB: “Monitoraggio in campo di pompe di calore” e si approfondisce lo studio di un impianto con pompa di calore acqua-acqua presentando un modello di supporto all’analisi del suo funzionamento in condizioni stazionarie. Il contributo allo sviluppo del sistema di monitoraggio è partito dall’analisi dei dati monitorati per la verifica della corretta installazione dei misuratori e si è concentrato sull’implementazione di filtri di validazione e di elaborazione dei dati raccolti. Il modello della pompa di calore è stato implementato in MATLAB e simula il comportamento in condizioni stazionarie della macchina in funzionamento ai carichi parziali. Dai dati ottenuti dalle simulazioni è stato possibile interpretare in maniera più accurata i risultati del monitoraggio.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
tesiFC.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Elaborato
Dimensione 12.78 MB
Formato Adobe PDF
12.78 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/109022