This thesis work aims to analyze the phenomenon of the air tightness in the wooden buildings by simulating cases in which there is absence or presence of mold and interstitial condensation. The most recent regulations used for this purpose are: UNI ISO EN 13788:2013 for the verification in stationary regime; UNI EN 15026:2008 for the verification in a dynamic regime; law UNI 10349-1 dated March 31st 2016 to use latest imposed climate data. What comes out is the importance of a correct design and the subsequently installation of the sealing elements in wooden buildings, since they are increasingly taking on a predominant role in the green building market. A further aim is to define which of the two mayor types of buildings in wood, that is Timber Frame and Cross Laminated Timber, gives the highest performance from the thermohygrometric point of wiew. This intent aims to provide help in choosing the most suitable construction system, in line with clients’ demands and the design and site preparation timing.
Il presente elaborato di tesi si pone come obiettivo quello di analizzare il fenomeno della tenuta all’aria negli edifici in legno, simulando i casi in cui si ha assenza e formazione di muffa e condensa interstiziale. A tale scopo sono state utilizzate le più recenti normative: per la verifica in regime stazionario si è utilizzata la UNI ISO EN 13788:2013; per la verifica in regime dinamico, la UNI EN 15026:2008; la norma UNI 10349-1 del 31 marzo 2016 per utilizzare i nuovi dati climatici imposti. Quello che si vuole fare emergere, è l’importanza che assumono la corretta progettazione e la successiva posa in opera degli elementi di tenuta all’aria negli edifici in legno, poiché questi ultimi stanno sempre più assumendo un ruolo predominante nel mercato della bioedilizia. Un ulteriore obiettivo è quello di stabilire quale tra le due maggiori tipologie edilizie in legno, ossia il Timber Frame e il Cross Laminated Timber, sia più performante dal punto di vista termoigrometrico. Tale intento mira a fornire un aiuto nella scelta del sistema costruttivo più adatto, coerentemente con le richieste della committenza e con le tempistiche di progettazione e di cantierizzazione.
La tenuta all'aria negli edifici in legno. Simulazioni in regime dinamico di casi studio sulla formazione di condensa interstiziale e muffa
GIUFFRIDA, MARTINA
2015/2016
Abstract
This thesis work aims to analyze the phenomenon of the air tightness in the wooden buildings by simulating cases in which there is absence or presence of mold and interstitial condensation. The most recent regulations used for this purpose are: UNI ISO EN 13788:2013 for the verification in stationary regime; UNI EN 15026:2008 for the verification in a dynamic regime; law UNI 10349-1 dated March 31st 2016 to use latest imposed climate data. What comes out is the importance of a correct design and the subsequently installation of the sealing elements in wooden buildings, since they are increasingly taking on a predominant role in the green building market. A further aim is to define which of the two mayor types of buildings in wood, that is Timber Frame and Cross Laminated Timber, gives the highest performance from the thermohygrometric point of wiew. This intent aims to provide help in choosing the most suitable construction system, in line with clients’ demands and the design and site preparation timing.| File | Dimensione | Formato | |
|---|---|---|---|
|
2016_09_Giuffrida.pdf
accessibile in internet per tutti
Descrizione: Testo della tesi
Dimensione
20.21 MB
Formato
Adobe PDF
|
20.21 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/125703