This work relates to the transients that occur in electric circuits when starting induction motors. These transients are characterized by large instantaneous current values, which can be mistaken for faults and cause undesired interventions of the protections. We studied the possibility of discriminating between the fault condition and the motor start of a three-phase asynchronous motor using the voltage and current measurements. For the latter, we assumed to measure the derivative, using sensors based on Rogowski coil. For this purpose, a technique based on the elaboration of the samples by the Least Squares Method has been developed, called Limit Detection Method, in which both the three-phase asynchronous motors that the circuits in the presence of a fault are represented as time-varying ohmic-inductive loads: the defined coefficients assume different values in the two cases, thus allowing their discrimination.
Questo lavoro riguarda i transitori che si registrano nei circuiti elettrici all’avviamento dei motori ad induzione. Questi transitori sono caratterizzati da elevati valori di corrente istantanea, che possono essere erroneamente considerati come guasti e provocare interventi intempestivi delle protezioni. Abbiamo quindi studiato la possibilità di discriminare la condizione di guasto dall’avviamento di un motore asincrono trifase utilizzando le misure di tensione e corrente. Per quest’ultima si è ipotizzato di misurare la derivata, utilizzando sensori basati sulla bobina di Rogowski. A questo scopo è stata sviluppata una tecnica basata sull’elaborazione dei campioni mediante il Metodo dei Minimi Quadrati, che abbiamo denominato Limit Detection Method, in cui sia i motori asincroni trifase che i circuiti in presenza di guasto vengono rappresentati come carichi ohmico-induttivi tempo varianti: vengono quindi definiti dei coefficienti che assumono valori diversi nei due casi, consentendo quindi di distinguerli.
Riconoscimento avviamenti di motori asincroni e rilevamento guasti in reti di bassa tensione
MATTIA, GIORGIO
2015/2016
Abstract
This work relates to the transients that occur in electric circuits when starting induction motors. These transients are characterized by large instantaneous current values, which can be mistaken for faults and cause undesired interventions of the protections. We studied the possibility of discriminating between the fault condition and the motor start of a three-phase asynchronous motor using the voltage and current measurements. For the latter, we assumed to measure the derivative, using sensors based on Rogowski coil. For this purpose, a technique based on the elaboration of the samples by the Least Squares Method has been developed, called Limit Detection Method, in which both the three-phase asynchronous motors that the circuits in the presence of a fault are represented as time-varying ohmic-inductive loads: the defined coefficients assume different values in the two cases, thus allowing their discrimination.File | Dimensione | Formato | |
---|---|---|---|
Tesi Giorgio Mattia.pdf
non accessibile
Descrizione: Testo della tesi
Dimensione
1.91 MB
Formato
Adobe PDF
|
1.91 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/133168