The seismic performance of steel structures significantly depends on the behavior of the beam-to-column connections. This study investigates the seismic response of an innovative beam-to-column connections, named bolted RBS. In case of strong earthquakes, damage concentrates in the reduced section of the beam, which can be easily replaced. In the first part of the work detailed finite element models of beam-to-column and frame sub-assemblages are created and analyzed. The distributions of plastic deformation are investigated and comparisons with standard and RBS connections are carried out. Parametric analisys has been performed on the connection, to detect possible variations of the global connection’s behaviour as function of design choices. Then the same studied connections has been introduced into finite element models of part of real structures, to understand their behaviour in a frame

La risposta sismica di strutture in acciaio dipende in maniera considerevole dal comportamento dei nodi trave-colonna utilizzati. La presente tesi ha per oggetto lo studio della risposta sismica di una tipologia innovativa di connessione trave-colonna, chiamata connessione RBS bullonata. Nel caso di terremoti di elevata intensità, il danno si concentra nella sezione ridotta della trave che può essere facilmente sostituita. Nell’elaborato sono stati sviluppati e analizzati modelli ad elementi finiti molto dettagliati di nodi trave-colonna. È stata studiata la distribuzione delle deformazioni plastiche e sono stati eseguiti confronti con connessioni tradizionali e RBS. Si è sviluppato uno studio parametrico della connessione determinando l’influenza che ogni scelta progettuale delle singole componenti comporta sulla risposta globale della connessione. Successivamente le medesime configurazioni di connessione studiate si sono introdotte in modelli ad elementi finiti di porzioni di struttura per osservarne il comportamento in un contesto strutturale

Analisi numeriche di nodi trave-colonna in acciaio con elemento sostituibile

CALDI, PIETRO;CASELLA, MICHELE
2016/2017

Abstract

The seismic performance of steel structures significantly depends on the behavior of the beam-to-column connections. This study investigates the seismic response of an innovative beam-to-column connections, named bolted RBS. In case of strong earthquakes, damage concentrates in the reduced section of the beam, which can be easily replaced. In the first part of the work detailed finite element models of beam-to-column and frame sub-assemblages are created and analyzed. The distributions of plastic deformation are investigated and comparisons with standard and RBS connections are carried out. Parametric analisys has been performed on the connection, to detect possible variations of the global connection’s behaviour as function of design choices. Then the same studied connections has been introduced into finite element models of part of real structures, to understand their behaviour in a frame
ING I - Scuola di Ingegneria Civile, Ambientale e Territoriale
27-lug-2017
2016/2017
La risposta sismica di strutture in acciaio dipende in maniera considerevole dal comportamento dei nodi trave-colonna utilizzati. La presente tesi ha per oggetto lo studio della risposta sismica di una tipologia innovativa di connessione trave-colonna, chiamata connessione RBS bullonata. Nel caso di terremoti di elevata intensità, il danno si concentra nella sezione ridotta della trave che può essere facilmente sostituita. Nell’elaborato sono stati sviluppati e analizzati modelli ad elementi finiti molto dettagliati di nodi trave-colonna. È stata studiata la distribuzione delle deformazioni plastiche e sono stati eseguiti confronti con connessioni tradizionali e RBS. Si è sviluppato uno studio parametrico della connessione determinando l’influenza che ogni scelta progettuale delle singole componenti comporta sulla risposta globale della connessione. Successivamente le medesime configurazioni di connessione studiate si sono introdotte in modelli ad elementi finiti di porzioni di struttura per osservarne il comportamento in un contesto strutturale
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
Tesi Magistrale nodi trave-colonna bullonati - Caldi Casella.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 20.75 MB
Formato Adobe PDF
20.75 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/135492