After the Fukushima accident in 2011, the market of the low cost nuclear detectors had a continuous development and spreading. This fact has generated great interests for the nuclear device manufacturers. In this paper, we want to investigate about the performances of these commercial detectors, characterizing them and calibrating them in an irradiation facility. The tests done include a performance screening, low dose rate and low energies irradiation, linearity and calibration verification (the latter was only made for two devices absent on the market). Some economic considerations regarding the instruments are done at the end of the work underlining the principal qualities of the instruments.
In seguito all'incidente di Fukushima avvenuto nel 2011 si ha assistito ad un continuo sviluppo e diffusione di rivelatori nucleari destinati al pubblico. Tale trend di crescita ha suscitato grande interesse da parte dei produttori di dispositivi nucleari nei confronti della cosiddetta "citizen science". Nel presente lavoro si è voluto approfondire ed indagare sugli aspetti prestazionali di tali rivelatori commerciali caratterizzandoli e calibrandoli in facility di irraggiamento. Sono stati considerati separatamente i rivelatori delle due categorie presenti in questo particolare mercato: i Geiger Muller counters ed i rivelatori a fotodiodo. Le prove effettuate comprendono uno screening prestazionale, irraggiamento a bassi dosi ed a basse energie, verifica della linearità e taratura (quest'ultima è stata fatta solo a due dispositivi non commercializzati). Non mancano infine alcune considerazioni economiche riguardanti gli strumenti.
Characterization of nuclear instruments for the citizen science
CARDANO, CORRADO
2016/2017
Abstract
After the Fukushima accident in 2011, the market of the low cost nuclear detectors had a continuous development and spreading. This fact has generated great interests for the nuclear device manufacturers. In this paper, we want to investigate about the performances of these commercial detectors, characterizing them and calibrating them in an irradiation facility. The tests done include a performance screening, low dose rate and low energies irradiation, linearity and calibration verification (the latter was only made for two devices absent on the market). Some economic considerations regarding the instruments are done at the end of the work underlining the principal qualities of the instruments.File | Dimensione | Formato | |
---|---|---|---|
2017_10_Cardano.pdf
non accessibile
Descrizione: Testo della tesi
Dimensione
5.64 MB
Formato
Adobe PDF
|
5.64 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/136669