Suturing in deep surgical field is a really complex procedure. Nowadays, commercially available sutures are made of polymeric or natural materials. These shows a high operator-dependency, strictly linked to the number of nodes and surgeon dexterity, which play an important role in the success of the surgery. So a NiTinol device which is able to automatically close was designed; this can limit the contraindications of the commercially available sutures. The objective of this work is to systematically reproduce the forming procedure. Moreover a thermo-mechanical characterization of the device is given and finally some finite elements simulations are conducted to be compared to the experimental findings. From these a further optimization study on the device geometry could start.

La procedura di sutura quando si opera nel campo profondo è molto difficoltosa. Attualmente vengono utilizzate suture commerciali in materiali polimerici o di origine naturale. Tali suture mostrano una operatore-dipendenza, legata al numero di nodi e alla manualità del chirurgo, che gioca un ruolo importante nella riuscita dell'intervento. Da qui l'esigenza di progettare un dispositivo in NiTinol autoannodante che limiti le controindicazioni delle suture commerciali. In questo lavoro di tesi si vuole dunque ripercorrere sistematicamente la procedura di produzione della sutura nella sua forma finale a partire dal trattamento termico sul filo NiTinol. Inoltre si vuole caratterizzare termo-meccanicamente il device e svolgere infine simulazioni computazionali preliminari a supporto dei test sperimentali svolti. Tali simulazioni saranno un punto di partenza per futuri studi indirizzati all’ottimizzazione della geometria del dispositivo.

Suture in nichel-titanio autoannodanti: trattamento termico e caratterizzazione termo-meccanica

DRAGHETTI, ANNA GRETA
2016/2017

Abstract

Suturing in deep surgical field is a really complex procedure. Nowadays, commercially available sutures are made of polymeric or natural materials. These shows a high operator-dependency, strictly linked to the number of nodes and surgeon dexterity, which play an important role in the success of the surgery. So a NiTinol device which is able to automatically close was designed; this can limit the contraindications of the commercially available sutures. The objective of this work is to systematically reproduce the forming procedure. Moreover a thermo-mechanical characterization of the device is given and finally some finite elements simulations are conducted to be compared to the experimental findings. From these a further optimization study on the device geometry could start.
BERTI, FRANCESCA
NESPOLI, ADELAIDE
PETRINI, LORENZA
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-dic-2017
2016/2017
La procedura di sutura quando si opera nel campo profondo è molto difficoltosa. Attualmente vengono utilizzate suture commerciali in materiali polimerici o di origine naturale. Tali suture mostrano una operatore-dipendenza, legata al numero di nodi e alla manualità del chirurgo, che gioca un ruolo importante nella riuscita dell'intervento. Da qui l'esigenza di progettare un dispositivo in NiTinol autoannodante che limiti le controindicazioni delle suture commerciali. In questo lavoro di tesi si vuole dunque ripercorrere sistematicamente la procedura di produzione della sutura nella sua forma finale a partire dal trattamento termico sul filo NiTinol. Inoltre si vuole caratterizzare termo-meccanicamente il device e svolgere infine simulazioni computazionali preliminari a supporto dei test sperimentali svolti. Tali simulazioni saranno un punto di partenza per futuri studi indirizzati all’ottimizzazione della geometria del dispositivo.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2017_12_Draghetti.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 8.48 MB
Formato Adobe PDF
8.48 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/138031