Permeable double skin facades are part of modern architectural concepts. An accurate assessment of the wind load on this kind of facades is crucial for a correct design and performance evaluation. Measuring and predicting DSF airflow is not a straightforward task, given the stochastic nature of the wind turbulence. Moreover Eurocode and many other National Codes do not supply any prescription about such issue. Here the comprehensive experimental study of wind loads acting on the porous double skin facade of the New Bocconi Campus is reported. Cladding loads assessment has been carried out performing wind tunnel tests on properly scaled rigid models. Peak pressures for the inner facade have been estimated and compared to the ones expected forcing a standard glazed facade. In addition, the current peak estimation method has been deeply analyzed and discussed. With reference to the TVL formula, the experimental results have represented a suitable framework in order to discuss the application of the equivalent time averaging filter and the dependency of the peak pressures estimation on the averaging time t.
Grazie ai recenti progressi tecnologici in architettura, molte soluzioni progettuali propongono l’adozione di facciate ventilate a doppia pelle porosa, il cui dimensionamento è dettato dalla determinazione del carico eolico sollecitante. L’azione del vento è funzione del carattere random della turbolenza incidente e dei campi di velocità e pressioni generati dall’interazione aerodinamica fluido-struttura. Le attuali norme di riferimento per il calcolo strutturale (i.e. Eurocodice) non trattano la progettazione di tali facciate. Il presente lavoro sviluppa lo studio sperimentale dei carichi eolici agenti sul sistema a doppia pelle porosa con facciata interna continua, ideato per il Nuovo Campus Bocconi. La stima delle pressioni di picco è stata condotta sulla base di prove commissionate ad-hoc presso la Galleria del Vento del Politecnico di Milano. Le misure sperimentali hanno permesso di quantificare l’effetto dello strato poroso in termini di valori estremi di carico eolico. Le correnti metodologie per la valutazione delle pressione di progetto sono state ampiamente affrontate. Nello specifico, lo studio sperimentale ha consentito una critica valutazione dell’effetto del filtro a media mobile e del periodo t, concettualmente legati alla formula TVL.
Peak pressures analysis on porous double skin facade : the new Bocconi Campus case study
DANIOTTI, NICOLÒ;POMARANZI, GIULIA
2016/2017
Abstract
Permeable double skin facades are part of modern architectural concepts. An accurate assessment of the wind load on this kind of facades is crucial for a correct design and performance evaluation. Measuring and predicting DSF airflow is not a straightforward task, given the stochastic nature of the wind turbulence. Moreover Eurocode and many other National Codes do not supply any prescription about such issue. Here the comprehensive experimental study of wind loads acting on the porous double skin facade of the New Bocconi Campus is reported. Cladding loads assessment has been carried out performing wind tunnel tests on properly scaled rigid models. Peak pressures for the inner facade have been estimated and compared to the ones expected forcing a standard glazed facade. In addition, the current peak estimation method has been deeply analyzed and discussed. With reference to the TVL formula, the experimental results have represented a suitable framework in order to discuss the application of the equivalent time averaging filter and the dependency of the peak pressures estimation on the averaging time t.File | Dimensione | Formato | |
---|---|---|---|
2017_12_Pomaranzi_Daniotti.pdf
non accessibile
Descrizione: Testo della tesi
Dimensione
59.92 MB
Formato
Adobe PDF
|
59.92 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/138158