The thesis mainly concerns the problem of seismic protection, that is more and more relevant nowadays, paying specific attention to non-structural elements collapse, through the application of drywall systems. The study focuses on masonry buildings with seismic resistant reinforced concrete structure, a very common architectural typology in Italy and abroad. The goal is to design a protective integrated structure that guarantees people’s safety from collapses of clay ceilings and walls, which are incapable of resisting the seismic strength. Therefore, we studied the behavior of seismic loaded secondary structures and calculated the seismic action and their resistance through various theories and regulations. We proceeded with the in-depth of the state of the art of seismic protection systems and drywall construction system, in particular Knauf’s systems. Based on these analyses we made some hypothesis of sizing concerning different loading situations and so designed the combined structure called DSN (Drywall Safety Net). The thesis proceeds with the application of the DSN through a case of study: the refurbishment of the complex Abitare 2006 in Boccaleone (Bergamo), which shows the perfect structural features: load bearing frame in reinforced concrete with masonry non-structural elements. The building and the annexed lot, now in state of abandon and decay, have been entirely redesigned to host multiple functions in a new urban park. The main use of the building is the innovative residential model of co-housing, in the case focused on brief to medium stays.
La tesi tratta principalmente il problema sempre più attuale della protezione dagli eventi sismici, in particolare per quanto concerne il crollo degli elementi non strutturali, attraverso l’applicazione di tecnologie stratificate a secco. Lo studio si focalizza sugli edifici in laterocemento con struttura sismo-resistente in calcestruzzo armato, la tipologia strutturale che riguarda gran parte del costruito nel territorio italiano e non solo. L’obbiettivo è quello di progettare una struttura protettiva integrata che permetta la salvaguardia delle persone sia dai distacchi del soffitto, che avvengono attraverso il fenomeno dello sfondellamento, sia dal crollo di tamponamenti e partizioni verticali in laterizio, inadatte a resistere alla forza del sisma. Si è quindi affrontato lo studio del comportamento delle strutture secondarie soggette ad azione sismica con il calcolo della stessa e della resistenza degli elementi, tramite l’ausilio di diverse teorie e normative. Si è proseguito con lo studio approfondito dello stato dell’arte dei sistemi di protezione antisismica e dei sistemi costruttivi stratificati a secco da utilizzare per il rinforzo, in particolare dei sistemi Knauf. Sulla base di queste analisi sono state fatte delle ipotesi di dimensionamento relative a diverse situazioni di carico ed è stata progettata la struttura integrata denominata DSN (Drywall Safety Net). La tesi prosegue con l’applicazione della DSN attraverso un caso studio: il recupero del complesso Abitare 2006 a Boccaleone (Bergamo) che strutturalmente presenta le caratteristiche ideali: telaio portante in calcestruzzo armato ed elementi di tamponamento in laterizio. L’edificio ed il lotto annesso, ora in stato di abbandono e degrado, sono stati interamente riprogettati per ospitare molteplici funzioni immerse nel nuovo parco attrezzato. La destinazione d’uso prevalente è quella dell’innovativo modello abitativo del co-housing, in questo caso focalizzato alle brevi e medie permanenze.
DSN. Drywall safety net : recupero e rinforzo antisismico con strutture secondarie stratificate a secco. Un caso di studio a Boccaleone, Bergamo
PALMIERI, SIMONE;COLNAGO, MARCO;COLOMBO, LORENZO
2016/2017
Abstract
The thesis mainly concerns the problem of seismic protection, that is more and more relevant nowadays, paying specific attention to non-structural elements collapse, through the application of drywall systems. The study focuses on masonry buildings with seismic resistant reinforced concrete structure, a very common architectural typology in Italy and abroad. The goal is to design a protective integrated structure that guarantees people’s safety from collapses of clay ceilings and walls, which are incapable of resisting the seismic strength. Therefore, we studied the behavior of seismic loaded secondary structures and calculated the seismic action and their resistance through various theories and regulations. We proceeded with the in-depth of the state of the art of seismic protection systems and drywall construction system, in particular Knauf’s systems. Based on these analyses we made some hypothesis of sizing concerning different loading situations and so designed the combined structure called DSN (Drywall Safety Net). The thesis proceeds with the application of the DSN through a case of study: the refurbishment of the complex Abitare 2006 in Boccaleone (Bergamo), which shows the perfect structural features: load bearing frame in reinforced concrete with masonry non-structural elements. The building and the annexed lot, now in state of abandon and decay, have been entirely redesigned to host multiple functions in a new urban park. The main use of the building is the innovative residential model of co-housing, in the case focused on brief to medium stays.File | Dimensione | Formato | |
---|---|---|---|
2017_12_Colnago_Colombo_Palmieri_01.pdf
accessibile in internet per tutti
Descrizione: Testo della tesi
Dimensione
74.39 MB
Formato
Adobe PDF
|
74.39 MB | Adobe PDF | Visualizza/Apri |
2017_12_Colnago_Colombo_Palmieri_02.pdf
accessibile in internet per tutti
Descrizione: Tavole di progetto
Dimensione
70.76 MB
Formato
Adobe PDF
|
70.76 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/138892