AC motors are very common instead of DC motors due to low cost, weight, less requirement of maintenance and ruggedness. However, the control of the AC machines requires much effort. Therefore, the control of the induction machine among the all AC motors has been mentioned. In addition, the subgroups, which are direct -field oriented control (DFOC) and indirect field -oriented control (IFOC), of field-oriented control (FOC) method have been proposed depending different systems. In the AC machines, the speed estimation of the motor is realized using the sensors. For this implementation, the additional electronics, extra wiring, extra surface, maintenance and careful mounting are required. Due to these reasons, speed sensorless induction motor drive has been improved. This control system is considered at different speed ranges. In medium-high frequencies, the methods which are voltage model, MRAS, full-order non-linear method and sliding mode belong to the fundamental wave mode. The results and conditions have been mentioned. Another method has been based on anisotropies at zero-low frequency. The rotor slot method and magnetic inductance saturation has been specified with results.

I motori CA sono molto comuni invece dei motori CC a causa del basso costo, del peso, della necessità di manutenzione e della robustezza. Tuttavia, il controllo delle macchine AC richiede molto sforzo. Pertanto, è stato menzionato il controllo della macchina ad induzione tra tutti i motori CA. Inoltre, i sottogruppi, che sono il controllo orientato al campo diretto (DFOC) e il controllo orientato al campo indiretto (IFOC), del metodo FOC (field-oriented control) sono stati proposti in base a sistemi diversi. Nelle macchine a corrente alternata, la stima della velocità del motore viene realizzata utilizzando i sensori. Per questa implementazione sono necessari l'elettronica aggiuntiva, il cablaggio supplementare, la superficie extra, la manutenzione e un montaggio accurato. Per questi motivi, è stata migliorata l'azionamento del motore a induzione senza sensori di velocità. Questo sistema di controllo è considerato a diversi intervalli di velocità. Nelle frequenze medio-alte, i metodi che sono modello di tensione, MRAS, metodo non lineare di ordine completo e modalità di scorrimento appartengono alla modalità d'onda fondamentale. I risultati e le condizioni sono stati menzionati. Un altro metodo è stato basato su anisotropie a frequenza zero-bassa. Il metodo di slot del rotore e la saturazione dell'induttanza magnetica sono stati specificati con i risultati.

Sensorless control of the induction machines

ISCEN, CANSU
2017/2018

Abstract

AC motors are very common instead of DC motors due to low cost, weight, less requirement of maintenance and ruggedness. However, the control of the AC machines requires much effort. Therefore, the control of the induction machine among the all AC motors has been mentioned. In addition, the subgroups, which are direct -field oriented control (DFOC) and indirect field -oriented control (IFOC), of field-oriented control (FOC) method have been proposed depending different systems. In the AC machines, the speed estimation of the motor is realized using the sensors. For this implementation, the additional electronics, extra wiring, extra surface, maintenance and careful mounting are required. Due to these reasons, speed sensorless induction motor drive has been improved. This control system is considered at different speed ranges. In medium-high frequencies, the methods which are voltage model, MRAS, full-order non-linear method and sliding mode belong to the fundamental wave mode. The results and conditions have been mentioned. Another method has been based on anisotropies at zero-low frequency. The rotor slot method and magnetic inductance saturation has been specified with results.
ING - Scuola di Ingegneria Industriale e dell'Informazione
19-apr-2018
2017/2018
I motori CA sono molto comuni invece dei motori CC a causa del basso costo, del peso, della necessità di manutenzione e della robustezza. Tuttavia, il controllo delle macchine AC richiede molto sforzo. Pertanto, è stato menzionato il controllo della macchina ad induzione tra tutti i motori CA. Inoltre, i sottogruppi, che sono il controllo orientato al campo diretto (DFOC) e il controllo orientato al campo indiretto (IFOC), del metodo FOC (field-oriented control) sono stati proposti in base a sistemi diversi. Nelle macchine a corrente alternata, la stima della velocità del motore viene realizzata utilizzando i sensori. Per questa implementazione sono necessari l'elettronica aggiuntiva, il cablaggio supplementare, la superficie extra, la manutenzione e un montaggio accurato. Per questi motivi, è stata migliorata l'azionamento del motore a induzione senza sensori di velocità. Questo sistema di controllo è considerato a diversi intervalli di velocità. Nelle frequenze medio-alte, i metodi che sono modello di tensione, MRAS, metodo non lineare di ordine completo e modalità di scorrimento appartengono alla modalità d'onda fondamentale. I risultati e le condizioni sono stati menzionati. Un altro metodo è stato basato su anisotropie a frequenza zero-bassa. Il metodo di slot del rotore e la saturazione dell'induttanza magnetica sono stati specificati con i risultati.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2018_04_Iscen.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Thesis text
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/139189