Direct tests to measure the hydraulic permeability of soft tissues are conceptually simple but difficult to perform and require very long times. The greatest difficulties in this measurement are related to the extremely low velocities involved, to the compaction and to the deformation of the solid matrix induced by the flow. Moreover, the microstructural phenomena that develop inside the soft tissues during the loading phase take a long time to develop completely and this complicates the measurement of permeability The following thesis work focused on the development of a new setup for the direct measurement of soft tissue permeability and the implementation of a control system for the same.
Le prove dirette per misurare la permeabilità idraulica dei tessuti molli sono concettualmente semplici ma difficili da svolgere e richiedono tempi molto lunghi. Le maggiori difficoltà in questa misurazione sono legate alle velocità estremamente basse coinvolte, alla compattazione ed alla deformazione della matrice solida indotta dal flusso. Inoltre, i fenomeni microstrutturali che si sviluppano all'interno dei tessuti molli in fase di carico richiedono molto tempo per svilupparsi completamente e ciò complica la misura della permeabilità Il seguente lavoro di tesi si è concentrato sullo sviluppo di un nuovo setup per la misura diretta della permeabilità di tessuti molli e sulla realizzazione di un sistema di controllo per lo stesso.
Sviluppo di un setup e di una procedura automatica per la misura della permeabilit idraulica dei tessuti molli
D'ALESIO, GIACOMO
2016/2017
Abstract
Direct tests to measure the hydraulic permeability of soft tissues are conceptually simple but difficult to perform and require very long times. The greatest difficulties in this measurement are related to the extremely low velocities involved, to the compaction and to the deformation of the solid matrix induced by the flow. Moreover, the microstructural phenomena that develop inside the soft tissues during the loading phase take a long time to develop completely and this complicates the measurement of permeability The following thesis work focused on the development of a new setup for the direct measurement of soft tissue permeability and the implementation of a control system for the same.File | Dimensione | Formato | |
---|---|---|---|
2018_04_DAlesio.pdf
non accessibile
Descrizione: Tesi
Dimensione
7.29 MB
Formato
Adobe PDF
|
7.29 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/140327