After discovering the harmful effects of synthetic halocarbon refrigerants, researchers ‎became motivated to search for environmentally friendly alternatives. Among natural ‎candidates, CO2 is somehow unique. It is Non-toxic, Non-flammable, with unique ‎thermophysical properties, high availability and low cost. An outstanding recent ‎project in this area is an innovative EU funded project referred to as MultiPACK. This ‎project aims to propose a successful All-In-One package for HVAC, tap water heating ‎and Refrigeration demands with a transcritical state of the art R744 solution. This ‎thesis has been dedicated to some work packages of this project assigned to NTNU. It ‎began with creating a console program written in C# language plus SQL-Server for ‎performing data extraction, transferring, synchronization, visualization and storing ‎logged measurement from two parallel independent logger systems. These loggers are ‎supplied by two members of MultiPACK consortium (Danfoss®, Enex s.r.l).‎ Since the MultiPACK project was in commissioning step, for the aim of data analysis, ‎a test rig in the NTNU lab was selected due to its similarity to the project's ‎installations. Then a test rig improvement was proposed by the author to give the ‎possibility of evaluating unexpected losses. The supplement data after system ‎modification turned out to be promising for inverter efficiency analysis.‎ Uncertainty analysis of the directly measured values and deduced results was done by ‎developing required code in the MATLAB, benefiting from the computerized CO2 ‎library (REFPROP[1]) to analyze non-explicit functions of measured data such as ‎evaporator load. Finally, non-conformity areas were detected and used to reject faulty ‎data. The resulted data disclosed the fact that the accuracy of several sensors can be ‎particularly critical to our calculated results and the results would be highly sensitive ‎to such a measurement instrument. The final necessary task was to reduce the high ‎measurement sample rates to minimize data volume with minimum information ‎loss. This task was carried out as well and is available for integration into the local ‎controllers of the installations.‎

Dopo aver scoperto gli effetti dannosi dei refrigeranti basati su alogenuri sintetici, i ‎ricercatori sono stati motivati a cercare alternative ecocompatibili. Tra i candidati ‎naturali, la CO2 è in qualche modo unica. Non è tossica, non è infiammabile, ha ‎proprietà termofisiche uniche, alta disponibilità e basso costo. Un importante e ‎recente progetto in questo settore, finanziato dall'UE, denominato MultiPACK. ‎Questo progetto mira a proporre un pacchetto All-In-One e per HVAC, riscaldamento ‎dell'acqua sanitaria e carichi termici di refrigerazione, con una soluzione R744 ‎transcritica e "state of the art". Questa tesi è dedicata ad alcuni WP di questo progetto, ‎assegnati a NTNU. È iniziata con la creazione di un programma scritto in linguaggio C ‎‎# e SQL-Server per l'esecuzione dell'estrazione, il trasferimento, la sincronizzazione, ‎la visualizzazione e l'archiviazione dei dati registrati da due sistemi di logging ‎indipendenti e paralleli. Questi sono forniti da due membri del consorzio MultiPACK ‎‎(Danfoss® ed Enex s.r.l.).‎ Dal momento che il progetto MultiPACK era in fase di commissioning, ai fini ‎dell'analisi dei dati è stato selezionato un banco di prova nel laboratorio NTNU, per la ‎sua somiglianza con le installazioni dei progetti. Quindi un miglioramento del banco ‎di prova è stato proposto dall'autore per dare la possibilità di valutare perdite ‎impreviste. I dati supplementari ottenuti dopo la modifica del sistema si sono ‎dimostrati promettenti per l'analisi dell'efficienza dell'inverter.‎ L'analisi dell'incertezza dei valori misurati direttamente e dei risultati dedotti è stata ‎effettuata sviluppando il codice richiesto in MATLAB, sfruttando una libreria di ‎calcolo per di CO2(REFPROP[1]) per analizzare funzioni non esplicite di dati misurati ‎come il carico dell'evaporatore. Infine, le aree di non conformità sono state rilevate e ‎utilizzate per rifiutare i dati difettosi. I dati risultanti hanno rivelato che l'accuratezza ‎di alcuni sensori può essere particolarmente critica per i risultati calcolati e che i ‎risultati sarebbero altamente sensibili a tale strumento di misurazione. L'ultimo ‎compito richiesto è stato ridurre le alte frequenze di misurazione per minimizzare il ‎volume dei dati con una perdita minima di informazione. Anche questo compito è ‎stato eseguito ed è disponibile per l'integrazione con i controller locali delle ‎installazioni.‎

Remote data collection, process and analysis of CO2 refrigeration systems

ALIPANAHI, ARMIN
2017/2018

Abstract

After discovering the harmful effects of synthetic halocarbon refrigerants, researchers ‎became motivated to search for environmentally friendly alternatives. Among natural ‎candidates, CO2 is somehow unique. It is Non-toxic, Non-flammable, with unique ‎thermophysical properties, high availability and low cost. An outstanding recent ‎project in this area is an innovative EU funded project referred to as MultiPACK. This ‎project aims to propose a successful All-In-One package for HVAC, tap water heating ‎and Refrigeration demands with a transcritical state of the art R744 solution. This ‎thesis has been dedicated to some work packages of this project assigned to NTNU. It ‎began with creating a console program written in C# language plus SQL-Server for ‎performing data extraction, transferring, synchronization, visualization and storing ‎logged measurement from two parallel independent logger systems. These loggers are ‎supplied by two members of MultiPACK consortium (Danfoss®, Enex s.r.l).‎ Since the MultiPACK project was in commissioning step, for the aim of data analysis, ‎a test rig in the NTNU lab was selected due to its similarity to the project's ‎installations. Then a test rig improvement was proposed by the author to give the ‎possibility of evaluating unexpected losses. The supplement data after system ‎modification turned out to be promising for inverter efficiency analysis.‎ Uncertainty analysis of the directly measured values and deduced results was done by ‎developing required code in the MATLAB, benefiting from the computerized CO2 ‎library (REFPROP[1]) to analyze non-explicit functions of measured data such as ‎evaporator load. Finally, non-conformity areas were detected and used to reject faulty ‎data. The resulted data disclosed the fact that the accuracy of several sensors can be ‎particularly critical to our calculated results and the results would be highly sensitive ‎to such a measurement instrument. The final necessary task was to reduce the high ‎measurement sample rates to minimize data volume with minimum information ‎loss. This task was carried out as well and is available for integration into the local ‎controllers of the installations.‎
HAFNER, ARMIN
ING - Scuola di Ingegneria Industriale e dell'Informazione
3-ott-2018
2017/2018
Dopo aver scoperto gli effetti dannosi dei refrigeranti basati su alogenuri sintetici, i ‎ricercatori sono stati motivati a cercare alternative ecocompatibili. Tra i candidati ‎naturali, la CO2 è in qualche modo unica. Non è tossica, non è infiammabile, ha ‎proprietà termofisiche uniche, alta disponibilità e basso costo. Un importante e ‎recente progetto in questo settore, finanziato dall'UE, denominato MultiPACK. ‎Questo progetto mira a proporre un pacchetto All-In-One e per HVAC, riscaldamento ‎dell'acqua sanitaria e carichi termici di refrigerazione, con una soluzione R744 ‎transcritica e "state of the art". Questa tesi è dedicata ad alcuni WP di questo progetto, ‎assegnati a NTNU. È iniziata con la creazione di un programma scritto in linguaggio C ‎‎# e SQL-Server per l'esecuzione dell'estrazione, il trasferimento, la sincronizzazione, ‎la visualizzazione e l'archiviazione dei dati registrati da due sistemi di logging ‎indipendenti e paralleli. Questi sono forniti da due membri del consorzio MultiPACK ‎‎(Danfoss® ed Enex s.r.l.).‎ Dal momento che il progetto MultiPACK era in fase di commissioning, ai fini ‎dell'analisi dei dati è stato selezionato un banco di prova nel laboratorio NTNU, per la ‎sua somiglianza con le installazioni dei progetti. Quindi un miglioramento del banco ‎di prova è stato proposto dall'autore per dare la possibilità di valutare perdite ‎impreviste. I dati supplementari ottenuti dopo la modifica del sistema si sono ‎dimostrati promettenti per l'analisi dell'efficienza dell'inverter.‎ L'analisi dell'incertezza dei valori misurati direttamente e dei risultati dedotti è stata ‎effettuata sviluppando il codice richiesto in MATLAB, sfruttando una libreria di ‎calcolo per di CO2(REFPROP[1]) per analizzare funzioni non esplicite di dati misurati ‎come il carico dell'evaporatore. Infine, le aree di non conformità sono state rilevate e ‎utilizzate per rifiutare i dati difettosi. I dati risultanti hanno rivelato che l'accuratezza ‎di alcuni sensori può essere particolarmente critica per i risultati calcolati e che i ‎risultati sarebbero altamente sensibili a tale strumento di misurazione. L'ultimo ‎compito richiesto è stato ridurre le alte frequenze di misurazione per minimizzare il ‎volume dei dati con una perdita minima di informazione. Anche questo compito è ‎stato eseguito ed è disponibile per l'integrazione con i controller locali delle ‎installazioni.‎
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
ArminAlipanahi_thesis_10510402.pdf

solo utenti autorizzati dal 18/09/2021

Descrizione: Thesis text
Dimensione 4.72 MB
Formato Adobe PDF
4.72 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/142876