The following research deals with the study and optimization of natural light in a museum. After having elaborated the project from an architectural point of view, suitable parametric solutions have been developed to allow the optimization of building in terms of daylighting. One of the fundamental objective of the thesis was verify that the internal space was functional for any type of artistic fitting, ensuring a certain flexibility to the different exhibition requirements. In particular, different types of existing shading have been considered and, starting from many scientific articles’ results, adequate systems have been developed for the building. Specifically, it has been evaluated the Illuminance, the daylight factor, the glare probability, the solar gains and the useful daylight illuminance performances and the obtained results were compared in order to define, among those proposed, the optimal configuration.

Il seguente lavoro tratta lo studio e l’ottimizzazione della luce naturale all’interno di un ambiente museale. Dopo aver elaborato il progetto da un punto di vista architettonico nella sua geometria, sono state sviluppate delle soluzioni adeguate che consentissero l’ottimizzazione degli interventi messi in atto in termini di daylighting. È stato inoltre obiettivo fondamentale della tesi verificare che l’ambiente in questione fosse funzionale per qualsiasi tipo di allestimento artistico garantendo quindi una certa flessibilità alle diverse esigenze espositive. Nello specifico, sono state considerate diverse tipologie di schermatura esistenti e a partire dall’analisi dei risultati di articoli scientifici sono stati sviluppati sistemi adeguati all’edificio mediante software parametrici. In particolare, sono state valutate le prestazioni di illuminamento, daylight factor, abbagliamento, guadagni solari e useful daylight illuminance e i risultati ottenuti sono stati confrontati al fine di definire, tra quelle proposte, la configurazione ottimale.

Analisi della luce naturale ed ottimizzazione del comfort luminoso in un edificio museale

RICCARDI, ANGELA
2017/2018

Abstract

The following research deals with the study and optimization of natural light in a museum. After having elaborated the project from an architectural point of view, suitable parametric solutions have been developed to allow the optimization of building in terms of daylighting. One of the fundamental objective of the thesis was verify that the internal space was functional for any type of artistic fitting, ensuring a certain flexibility to the different exhibition requirements. In particular, different types of existing shading have been considered and, starting from many scientific articles’ results, adequate systems have been developed for the building. Specifically, it has been evaluated the Illuminance, the daylight factor, the glare probability, the solar gains and the useful daylight illuminance performances and the obtained results were compared in order to define, among those proposed, the optimal configuration.
POLI, TIZIANA
ARC I - Scuola di Architettura Urbanistica Ingegneria delle Costruzioni
3-ott-2018
2017/2018
Il seguente lavoro tratta lo studio e l’ottimizzazione della luce naturale all’interno di un ambiente museale. Dopo aver elaborato il progetto da un punto di vista architettonico nella sua geometria, sono state sviluppate delle soluzioni adeguate che consentissero l’ottimizzazione degli interventi messi in atto in termini di daylighting. È stato inoltre obiettivo fondamentale della tesi verificare che l’ambiente in questione fosse funzionale per qualsiasi tipo di allestimento artistico garantendo quindi una certa flessibilità alle diverse esigenze espositive. Nello specifico, sono state considerate diverse tipologie di schermatura esistenti e a partire dall’analisi dei risultati di articoli scientifici sono stati sviluppati sistemi adeguati all’edificio mediante software parametrici. In particolare, sono state valutate le prestazioni di illuminamento, daylight factor, abbagliamento, guadagni solari e useful daylight illuminance e i risultati ottenuti sono stati confrontati al fine di definire, tra quelle proposte, la configurazione ottimale.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2018_10_Riccardi.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 7.09 MB
Formato Adobe PDF
7.09 MB Adobe PDF   Visualizza/Apri
2018_10_Riccardi_01.pdf

non accessibile

Descrizione: Allegato 1
Dimensione 258.81 kB
Formato Adobe PDF
258.81 kB Adobe PDF   Visualizza/Apri
2018_10_Riccardi_02.pdf

non accessibile

Descrizione: Allegato 2
Dimensione 214.32 kB
Formato Adobe PDF
214.32 kB Adobe PDF   Visualizza/Apri
2018_10_Riccardi_03.pdf

non accessibile

Descrizione: Allegato 3
Dimensione 137.29 kB
Formato Adobe PDF
137.29 kB Adobe PDF   Visualizza/Apri
2018_10_Riccardi_04.pdf

non accessibile

Descrizione: Allegato 4
Dimensione 420.35 kB
Formato Adobe PDF
420.35 kB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/143029