In an historical period in which the attention to the consumption of industrial polluting substances is constantly growing, the need to develop accurate devices that allow to detect, monitor and regulate minimal quantities of environmental harmful agents increase more and more. The aim of the thesis is to improve the performance of some optoelectronics sensors for the detection and measurement of minimal oil flows, both in the form of striation and fog. The first project, concerning the striation of oil, has occupied most of the thesis work. To a detection system that partially satisfied the customer's requests, after a first characterization process, hardware and software changes were made to make it suitable for the project specifications. Furthermore, after the modifications, it was possible to carry out a study on the position in the pipe which allowed to improve the reliability of measurement. The second part, concerning the measurement of the nebulized oil, had as its objective the mathematical modeling of the response of a sensor analyzed in previous thesis projects, in order to be able to deduce different parameters of the lubrication system. The study was commissioned by the company MWM Schmieranlagen Srl and in collaboration with BTSR SpA.

In un periodo storico in cui cresce costantemente la sensibilizzazione verso la riduzione dei consumi di sostanze inquinanti impiegate in ambito industriale, aumenta di pari passo la necessità di sviluppare dispositivi sempre più accurati che consentano di rilevare, monitorare e regolare quantità minime di agenti dannosi all’ambiente. Lo scopo della tesi riguarda il miglioramento delle prestazioni di sensori optoelettronici per la rilevazione e la misura di flussi d’olio minimali, sia sotto forma di striatura, che di nebbia. Il primo progetto, ovvero quello riguardante la striatura d’olio, racchiude la maggior parte del lavoro di tesi. Ad un sistema di rilevazione che soddisfaceva in parte le richieste del cliente, a seguito di una prima caratterizzazione, sono state apportate modifiche hardware e software tali da renderlo adatto alle specifiche di progetto. Inoltre, a seguito delle rettifiche compiute, è stato possibile svolgere uno studio sulla posizione della striatura nel tubo che ha permesso significativi miglioramenti nell’affidabilità di misura. La seconda parte, riguardante la misura dell’olio nebulizzato, ha avuto come obiettivo la modellazione matematica della risposta di un sensore analizzato in elaborati di tesi precedenti, per poter dedurre diversi parametri del sistema di lubrificazione. Lo studio è stato commissionato dalla ditta MWM Schmieranlagen Srl, in collaborazione con BTSR SpA.

Sensori optoelettronici per lubrificazione minimale

CHIESA, LUCA
2018/2019

Abstract

In an historical period in which the attention to the consumption of industrial polluting substances is constantly growing, the need to develop accurate devices that allow to detect, monitor and regulate minimal quantities of environmental harmful agents increase more and more. The aim of the thesis is to improve the performance of some optoelectronics sensors for the detection and measurement of minimal oil flows, both in the form of striation and fog. The first project, concerning the striation of oil, has occupied most of the thesis work. To a detection system that partially satisfied the customer's requests, after a first characterization process, hardware and software changes were made to make it suitable for the project specifications. Furthermore, after the modifications, it was possible to carry out a study on the position in the pipe which allowed to improve the reliability of measurement. The second part, concerning the measurement of the nebulized oil, had as its objective the mathematical modeling of the response of a sensor analyzed in previous thesis projects, in order to be able to deduce different parameters of the lubrication system. The study was commissioned by the company MWM Schmieranlagen Srl and in collaboration with BTSR SpA.
ING - Scuola di Ingegneria Industriale e dell'Informazione
20-dic-2018
2018/2019
In un periodo storico in cui cresce costantemente la sensibilizzazione verso la riduzione dei consumi di sostanze inquinanti impiegate in ambito industriale, aumenta di pari passo la necessità di sviluppare dispositivi sempre più accurati che consentano di rilevare, monitorare e regolare quantità minime di agenti dannosi all’ambiente. Lo scopo della tesi riguarda il miglioramento delle prestazioni di sensori optoelettronici per la rilevazione e la misura di flussi d’olio minimali, sia sotto forma di striatura, che di nebbia. Il primo progetto, ovvero quello riguardante la striatura d’olio, racchiude la maggior parte del lavoro di tesi. Ad un sistema di rilevazione che soddisfaceva in parte le richieste del cliente, a seguito di una prima caratterizzazione, sono state apportate modifiche hardware e software tali da renderlo adatto alle specifiche di progetto. Inoltre, a seguito delle rettifiche compiute, è stato possibile svolgere uno studio sulla posizione della striatura nel tubo che ha permesso significativi miglioramenti nell’affidabilità di misura. La seconda parte, riguardante la misura dell’olio nebulizzato, ha avuto come obiettivo la modellazione matematica della risposta di un sensore analizzato in elaborati di tesi precedenti, per poter dedurre diversi parametri del sistema di lubrificazione. Lo studio è stato commissionato dalla ditta MWM Schmieranlagen Srl, in collaborazione con BTSR SpA.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2018_12_Chiesa.pdf

non accessibile

Descrizione: SENSORI OPTOELETTRONICI PER LUBRIFICAZIONE MINIMALE
Dimensione 19.18 MB
Formato Adobe PDF
19.18 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/144701