Stray currents originating from DC electrical systems may cause severe corrosion damage of buried metal structures, as carbon steel pipes, tanks or vessels. Nowdays, international standards establish the genearal principles to control DC interference, mainly based on potential and current gradients measurements over a 24 h period. As regards carbon steel undere cathodic protection condition, anodic Dc interference in considered unacceptable if the IR-free potential is more positive than the protection potential provided by standard (-0.85 V CSE in aerobic condition).But, duration, frequency, intensity of the anodic peak and pH of the environment, should be considered to evaluate the actual corrosion effects of the interference on the protected steel. Thi thesis deals with the study of the effects of anodic interference on buried carbon steel structures in cathodic protection: corrosion rates measurements were carried out on cathodically protected steel specimens in soil simulating environment in the presence of DC interference varyng anodic potentials.
Le correnti non stazionarie originate da interferenza a corrente continua, possono causare danni pericolosi sulle strutture metalliche interrate, come tubazioni, valvole e serbatoi in acciaio al carbonio. Oggigiorno, gli standard internazionali, hanno stabilito i principi generali per controllare le interferenze a corrente continua, basandosi principalmente sulle misurazioni di variazione di potenziale e corrente fatte su un periodo maggiore di 24 ore. Per quanto riguarda l'acciaio al carbonio sotto protezione catodica, l'interferenza a corrente continua non stazionaria e considerata non accettabile se il potenziale di corrosione è più positivo rispetto al potenziale di protezione, fornito dagli standard (-0.85 V CSE in condizioni areate). Ma la durata, la frequenza, l'intensità dell'interferenza, insieme con il pH della soluzione in cui è immersa la sruttura metallica, sono tutti fattori che devono essere considerati valutare l'attuale effetto della corrosione delle interferenze sulle strutture protette catodicamente. Questa tesi, tratta dello studio degli effetti delle interferenze a correnti continue non stazionarie sulle strutture in acciaio al carbonio interrate e protette catodicamente: sono state effettuate delle misurazioni di tassi di corrosione su provini protetti catodicamenti e immersi in una soluzione simulante terreno in presenza di interferenze anodiche, variando il potenziale di corrosione.
Effects of non-stationary DC interference on the cathodic protection of carbon steel pipeline in soil
BEI, WALTER
2017/2018
Abstract
Stray currents originating from DC electrical systems may cause severe corrosion damage of buried metal structures, as carbon steel pipes, tanks or vessels. Nowdays, international standards establish the genearal principles to control DC interference, mainly based on potential and current gradients measurements over a 24 h period. As regards carbon steel undere cathodic protection condition, anodic Dc interference in considered unacceptable if the IR-free potential is more positive than the protection potential provided by standard (-0.85 V CSE in aerobic condition).But, duration, frequency, intensity of the anodic peak and pH of the environment, should be considered to evaluate the actual corrosion effects of the interference on the protected steel. Thi thesis deals with the study of the effects of anodic interference on buried carbon steel structures in cathodic protection: corrosion rates measurements were carried out on cathodically protected steel specimens in soil simulating environment in the presence of DC interference varyng anodic potentials.File | Dimensione | Formato | |
---|---|---|---|
2018_12_Bei.pdf
accessibile in internet solo dagli utenti autorizzati
Descrizione: Testo tesi
Dimensione
2.48 MB
Formato
Adobe PDF
|
2.48 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/145260