This work consists in a preliminary analysis of the origins of the dicrotic notch. The study is performed using two different numerical model configurations: one that consists of a one-dimensional model of the upper thoracic aorta with an RCR model as boundary condition and a given inlet blood flow function, the other one differs from the previous one because it include, at the inlet, a coupling with a reduced-dimensional model of the heart. The peculiarity of the formulation for the one-dimensional model is that it preserves a given energy relation at the discrete level, this guarantees a good stability and accuracy of the method for the coupling with the model of the cardiac cavity.
Questo lavoro consiste in un'analisi preliminare delle origini dell'incisura dicrota. Lo studio é realizzato utilizzando un modello numerico in due diverse configurazioni: uno si compone di un modello unidimensionale dell'aorta toracica superiore con un modello RCR come condizione di contorno in uscita e una funzione di portata data in entrata, l'altro modello si differenzia dal precedente in quanto include, in ingresso, un accoppiamento con un modello ridotto di cuore. La peculiarità della formulazione per il modello unidimensionale é la sua capacita di preservare una relazione di energia data a livello discreto, questo garantisce stabilità e accuratezza del metodo per l'accoppiamento con il modello di cavità cardiaca.
Origins of the dicrotic notch : a preliminary study using an original energy-consistent reduced-dimensional cardiovascular model
MANGANOTTI, JESSICA
2017/2018
Abstract
This work consists in a preliminary analysis of the origins of the dicrotic notch. The study is performed using two different numerical model configurations: one that consists of a one-dimensional model of the upper thoracic aorta with an RCR model as boundary condition and a given inlet blood flow function, the other one differs from the previous one because it include, at the inlet, a coupling with a reduced-dimensional model of the heart. The peculiarity of the formulation for the one-dimensional model is that it preserves a given energy relation at the discrete level, this guarantees a good stability and accuracy of the method for the coupling with the model of the cardiac cavity.| File | Dimensione | Formato | |
|---|---|---|---|
|
MANGANOTTI_Jessica_tesi_2.pdf
non accessibile
Descrizione: Testo della tesi corretto
Dimensione
7.99 MB
Formato
Adobe PDF
|
7.99 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/146234