In this thesis work, a confining fluid PVT dilatometer by GNOMIX INC. was used. This apparatus operates mostly with mercury as confining fluid, but also water and 210H silicon oil can be utilized. The data acquisition system (electronic boards and wiring) was modified and a new software to control the apparatus had to be developed to replace the old one, that was outdated. LabVIEW was used to design this new program. The main issue was to set up pressure and temperature control. In particular, two methods were investigated to control temperature: a two-positions controller and a PID controller. The program was developed, and a calibration run on mercury and an isothermal compression on an isotactic polypropylene were performed. Results were compared to the old ones to prove the program properly functioning.
In questo lavoro è stato usato un dilatometro PVT a fluido confinante prodotto dalla GNOMIX INC. Questo apparato funziona principalmente usando mercurio come fluido confinante, ma possono essere utilizzati anche acqua e olio siliconico. Il sistema di acquisizione dei dati (schede elettroniche e connessioni) è stato modificato ed è stato necessario sviluppare un nuovo software di controllo per sostituire il precedente sistema, che era obsoleto. Per scrivere il nuovo programma è stato usato il software di programmazione grafica LabVIEW. Il problema principale è stato definire il controllo di pressione e temperatura. In particolare, sono state investigate due possibilità per i metodi di controllo della temperatura: un controllore a due posizioni e un controllore PID. Il programma è stato messo a punto e sono state effettuate una prova di calibrazione sul mercurio e una compressione isoterma su un polipropilene isotattico. I risultati così generati sono stati confrontati con dati ottenuti in passato per verificare il corretto funzionamento del programma.
Implementation of a new acquisition and control system for a pressure dilatometer
CERETI, ANNACARLA
2018/2019
Abstract
In this thesis work, a confining fluid PVT dilatometer by GNOMIX INC. was used. This apparatus operates mostly with mercury as confining fluid, but also water and 210H silicon oil can be utilized. The data acquisition system (electronic boards and wiring) was modified and a new software to control the apparatus had to be developed to replace the old one, that was outdated. LabVIEW was used to design this new program. The main issue was to set up pressure and temperature control. In particular, two methods were investigated to control temperature: a two-positions controller and a PID controller. The program was developed, and a calibration run on mercury and an isothermal compression on an isotactic polypropylene were performed. Results were compared to the old ones to prove the program properly functioning.File | Dimensione | Formato | |
---|---|---|---|
TESI CERETI.pdf
accessibile in internet solo dagli utenti autorizzati
Descrizione: Testo della tesi
Dimensione
4.06 MB
Formato
Adobe PDF
|
4.06 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/152125