The replacement of a missing tooth with a dental implant is a common and clinically accepted technique, although some complications persist and cause implant failure. For this reason, in the last few years, finite element analysis (FEA) have been combined with experimental test to evaluate the mechanical performances of dental implants; In FEA contest, this study is intended to examine the adhesive bond strength in two-components hybrid abutment, taking into account the influence of factors like dental models, materials and boundary conditions. Differently from other previous studies, which analyzed the failure of dental implants and adhesive joints separately, this work aimed to integrate these two arguments in a single computational model; the adhesive cements were treated as plastic materials which properties softens due to shear damage. The first simulations followed the Standard ISO14801, but than other loading conditions were investigated for the main purpose of finding the best setup which replicates the clinical conditions.

La sostituzione dei denti mancanti con impianti dentali è una tecnica comune e clinicamente accettata, tuttavia persistono alcune complicazioni che ne provocano il fallimento. Per questo motivo, negli ultimi anni, analisi ad elementi finiti (FEA) si sono affiancate a prove sperimenti per verificare l’affidabilità dei dispositivi dentali; questo studio si inserisce nel contesto FEA con lo scopo di effettuare analisi di resistenza dell’interfaccia adesiva in monconi ibridi multicomponente, analizzando l’influenza di fattori quali modello dentale, tipo di materiale e configurazioni di vincolo. A differenza degli studi della letteratura che affrontano separatamente il fallimento di impianti dentali e giunti adesivi, questo lavoro ha voluto integrare i due argomenti in un unico modello computazionale; in particolare si è preso in considerazione il comportamento plastico a danneggiamento dei cementi adesivi, caratterizzato dal fenomeno di degradazione delle proprietà. Dopo aver eseguito le prime simulazioni secondo norma ISO14801, si sono analizzate altre configurazioni di carico al fine di trovare quella che replicasse meglio la condizione clinica.

Studio ad elementi finiti di impianti per la sostituzione di canini e premolari : stabilità meccanica della resina all'interfaccia in impianti con monconi multi-componente

GALLAN, MICHELA
2018/2019

Abstract

The replacement of a missing tooth with a dental implant is a common and clinically accepted technique, although some complications persist and cause implant failure. For this reason, in the last few years, finite element analysis (FEA) have been combined with experimental test to evaluate the mechanical performances of dental implants; In FEA contest, this study is intended to examine the adhesive bond strength in two-components hybrid abutment, taking into account the influence of factors like dental models, materials and boundary conditions. Differently from other previous studies, which analyzed the failure of dental implants and adhesive joints separately, this work aimed to integrate these two arguments in a single computational model; the adhesive cements were treated as plastic materials which properties softens due to shear damage. The first simulations followed the Standard ISO14801, but than other loading conditions were investigated for the main purpose of finding the best setup which replicates the clinical conditions.
SPINDLER, BRUNO
VENA, PASQUALE
ING - Scuola di Ingegneria Industriale e dell'Informazione
29-apr-2020
2018/2019
La sostituzione dei denti mancanti con impianti dentali è una tecnica comune e clinicamente accettata, tuttavia persistono alcune complicazioni che ne provocano il fallimento. Per questo motivo, negli ultimi anni, analisi ad elementi finiti (FEA) si sono affiancate a prove sperimenti per verificare l’affidabilità dei dispositivi dentali; questo studio si inserisce nel contesto FEA con lo scopo di effettuare analisi di resistenza dell’interfaccia adesiva in monconi ibridi multicomponente, analizzando l’influenza di fattori quali modello dentale, tipo di materiale e configurazioni di vincolo. A differenza degli studi della letteratura che affrontano separatamente il fallimento di impianti dentali e giunti adesivi, questo lavoro ha voluto integrare i due argomenti in un unico modello computazionale; in particolare si è preso in considerazione il comportamento plastico a danneggiamento dei cementi adesivi, caratterizzato dal fenomeno di degradazione delle proprietà. Dopo aver eseguito le prime simulazioni secondo norma ISO14801, si sono analizzate altre configurazioni di carico al fine di trovare quella che replicasse meglio la condizione clinica.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2020_04_Gallan.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 8.51 MB
Formato Adobe PDF
8.51 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/154213