The recent studies on energy efficient design for various climatic conditions have shown a unique solution of using ventilate façade cladding. Apart from being a solution to new construction, it is considered to be a most efficient solution for existing buildings that are in need of renovation. The sudden reliance on energy efficient construction has created a bigger market for ventilated façade industry. There are immeasurable research works on the ventilated facade and all of it somehow concluded with its beneficial outlook. With wide range of merits, ventilated façade is now being employed in residential buildings, commercial buildings and industrial buildings to reduce the electrical energy consumptions. The ventilated façade consists of an external cladding attached to a substructure made up of brackets, vertical profile, anchors, hooks each of it varying depending on the type of façade used. The façade engineer designs the façade components based on its structural performance in relation to the substrate. The substrate and the substructure components vary depending upon the requirements specified by the client. With the wide choice of materials and components available, the clients have the possibility to choose the desired façade system. While the façade engineers have to cope up with needs and demands of the client. The shop drawings of the structural grid and the slab grid consume a lot of time and there could be human error. With BIM, the openings, slabs, windows, doors and other elements will be recognized and the substructure of the ventilated façade will be laid. For accuracy in fabrication and installation, the façade design requires a level of LOD400 or more to facilitate the fabricator and the installer. Hence, the façade engineers are obliged to provide the modelling with a level of LOD400 which can be achieved with the implementation of BIM.

I recenti studi sulla progettazione efficiente dal punto di vista energetico per varie condizioni climatiche hanno mostrato una soluzione unica per l'utilizzo di rivestimenti ventilati per facciate. Oltre ad essere una soluzione per le nuove costruzioni, è considerata una soluzione più efficiente per gli edifici esistenti che necessitano di ristrutturazione. L'improvvisa dipendenza da costruzioni efficienti dal punto di vista energetico ha creato un mercato più ampio per l'industria delle facciate ventilate. Ci sono incommensurabili lavori di ricerca sulla facciata ventilata e tutto in qualche modo si è concluso con il suo aspetto benefico. Con un'ampia gamma di vantaggi, la facciata ventilata viene ora impiegata in edifici residenziali, edifici commerciali e edifici industriali per ridurre i consumi di energia elettrica. La facciata ventilata è costituita da un rivestimento esterno fissato ad una sottostruttura composta da staffe, profilo verticale, tasselli, ganci ciascuno variabile a seconda del tipo di facciata utilizzata. L'ingegnere della facciata progetta i componenti della facciata in base alle sue prestazioni strutturali in relazione al substrato. Il substrato e i componenti della sottostruttura variano a seconda dei requisiti specificati dal cliente. Con l'ampia scelta di materiali e componenti disponibili, i clienti hanno la possibilità di scegliere il sistema di facciata desiderato. Mentre gli ingegneri delle facciate devono far fronte alle esigenze e alle richieste del cliente. I disegni esecutivi della griglia strutturale e della griglia del solaio richiedono molto tempo e potrebbero esserci errori umani. Con il BIM verranno riconosciute le aperture, i solai, le finestre, le porte e altri elementi e verrà posata la sottostruttura della facciata ventilata. Per la precisione nella fabbricazione e nell'installazione, il design della facciata richiede un livello di LOD400 o superiore per facilitare il produttore e l'installatore. Pertanto, gli ingegneri delle facciate sono obbligati a fornire alla modellazione un livello di LOD400 che può essere raggiunto con l'implementazione del BIM.

Ventilated facade design engineering supported by BIM and visual programming tools

Thirrumurthi Dhanabakiyam, Maduri Preethika
2019/2020

Abstract

The recent studies on energy efficient design for various climatic conditions have shown a unique solution of using ventilate façade cladding. Apart from being a solution to new construction, it is considered to be a most efficient solution for existing buildings that are in need of renovation. The sudden reliance on energy efficient construction has created a bigger market for ventilated façade industry. There are immeasurable research works on the ventilated facade and all of it somehow concluded with its beneficial outlook. With wide range of merits, ventilated façade is now being employed in residential buildings, commercial buildings and industrial buildings to reduce the electrical energy consumptions. The ventilated façade consists of an external cladding attached to a substructure made up of brackets, vertical profile, anchors, hooks each of it varying depending on the type of façade used. The façade engineer designs the façade components based on its structural performance in relation to the substrate. The substrate and the substructure components vary depending upon the requirements specified by the client. With the wide choice of materials and components available, the clients have the possibility to choose the desired façade system. While the façade engineers have to cope up with needs and demands of the client. The shop drawings of the structural grid and the slab grid consume a lot of time and there could be human error. With BIM, the openings, slabs, windows, doors and other elements will be recognized and the substructure of the ventilated façade will be laid. For accuracy in fabrication and installation, the façade design requires a level of LOD400 or more to facilitate the fabricator and the installer. Hence, the façade engineers are obliged to provide the modelling with a level of LOD400 which can be achieved with the implementation of BIM.
DANIOTTI, BRUNO
CAFFI, VITTORIO
ARC I - Scuola di Architettura Urbanistica Ingegneria delle Costruzioni
28-apr-2021
2019/2020
I recenti studi sulla progettazione efficiente dal punto di vista energetico per varie condizioni climatiche hanno mostrato una soluzione unica per l'utilizzo di rivestimenti ventilati per facciate. Oltre ad essere una soluzione per le nuove costruzioni, è considerata una soluzione più efficiente per gli edifici esistenti che necessitano di ristrutturazione. L'improvvisa dipendenza da costruzioni efficienti dal punto di vista energetico ha creato un mercato più ampio per l'industria delle facciate ventilate. Ci sono incommensurabili lavori di ricerca sulla facciata ventilata e tutto in qualche modo si è concluso con il suo aspetto benefico. Con un'ampia gamma di vantaggi, la facciata ventilata viene ora impiegata in edifici residenziali, edifici commerciali e edifici industriali per ridurre i consumi di energia elettrica. La facciata ventilata è costituita da un rivestimento esterno fissato ad una sottostruttura composta da staffe, profilo verticale, tasselli, ganci ciascuno variabile a seconda del tipo di facciata utilizzata. L'ingegnere della facciata progetta i componenti della facciata in base alle sue prestazioni strutturali in relazione al substrato. Il substrato e i componenti della sottostruttura variano a seconda dei requisiti specificati dal cliente. Con l'ampia scelta di materiali e componenti disponibili, i clienti hanno la possibilità di scegliere il sistema di facciata desiderato. Mentre gli ingegneri delle facciate devono far fronte alle esigenze e alle richieste del cliente. I disegni esecutivi della griglia strutturale e della griglia del solaio richiedono molto tempo e potrebbero esserci errori umani. Con il BIM verranno riconosciute le aperture, i solai, le finestre, le porte e altri elementi e verrà posata la sottostruttura della facciata ventilata. Per la precisione nella fabbricazione e nell'installazione, il design della facciata richiede un livello di LOD400 o superiore per facilitare il produttore e l'installatore. Pertanto, gli ingegneri delle facciate sono obbligati a fornire alla modellazione un livello di LOD400 che può essere raggiunto con l'implementazione del BIM.
File allegati
File Dimensione Formato  
2021_4_ThirrumuthiDhanabakiyam.pdf

non accessibile

Descrizione: VENTILATED FAÇADE DESIGN ENGINEERING SUPPORTED BY BIM AND VISUAL PROGRAMMING TOOLS
Dimensione 9.49 MB
Formato Adobe PDF
9.49 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/173984