The following thesis work is part of the studies on the management of contaminated sites and the evaluation of remediation and/or safety interventions aimed at evaluating and comparing different approaches and possible intervention scenarios. In particular, the thesis addresses the study of a site where there is an on-going intervention of pump and treat with delivery of drawn groundwater in sewage, in which there is an interest to identify alternative scenarios of management of pumped water, also in the view of the introduction of regional regulations on plumbing invariance. Thanks to a numerical modeling of the groundwater flow, to the local scale of the site, it was possible to explore and simulate different possible solutions. The study initially required the reconstruction of the physical model of the subsoil and its geology and hydrogeology through research and consultation of the documentation available on the study area and its implementation within the software GMS, interface to the Modflow calculation code. Through the model it was able to evaluate several possible scenarios for the management of contamination (pumped groundwater reimmission, permeable reactive reactive - PRB). A particularly interesting aspect, even for the implications on remediation activities, is that the site is part of an area of widespread pollution for organochlorine solvents so, in addition to managing the contamination of the site, the system is exposed to external polluting loads.

Il presente lavoro di tesi si inquadra nell’ambito degli studi sulla gestione dei siti contaminati e di valutazione degli interventi di bonifica e/o messa in sicurezza finalizzati a valutare e comparare diversi approcci e scenari d’intervento possibili. In particolare, la tesi affronta lo studio di un sito dove è attualmente in corso un intervento di pump and treat con recapito delle acque emunte in fognatura, in cui c’è l’interesse a individuare scenari alternativi di gestione delle acque emunte, anche alla luce dell’introduzione dei regolamenti regionali in tema di invarianza idraulica. Attraverso una modellazione numerica del flusso delle acque sotterranee, alla scala locale del sito, è stato possibile esplorare e simulare diverse possibili soluzioni. Lo studio ha richiesto inizialmente la ricostruzione del modello fisico del sottosuolo e della sua geologia e idrogeologia attraverso la ricerca e consultazione della documentazione disponibile sull’area di studio e la sua implementazione all’interno del software GMS, interfaccia al codice di calcolo Modflow. Attraverso il modello è stato possibile valutare diversi possibili scenari per la gestione della contaminazione (reimmissione delle acque emunte, barriera permeabile reattiva – PRB). Un aspetto particolarmente interessante che è emerso, anche per i risvolti sulle attività di bonifica, è il fatto che il sito si inserisce in un’area di inquinamento diffuso da solventi organoclorurati per cui, oltre a gestire la contaminazione del sito, l’impianto è esposto a carichi inquinanti esterni.

Valutazione di scenari di gestione della contaminazione di falda : un caso studio

Ratti, Monica
2020/2021

Abstract

The following thesis work is part of the studies on the management of contaminated sites and the evaluation of remediation and/or safety interventions aimed at evaluating and comparing different approaches and possible intervention scenarios. In particular, the thesis addresses the study of a site where there is an on-going intervention of pump and treat with delivery of drawn groundwater in sewage, in which there is an interest to identify alternative scenarios of management of pumped water, also in the view of the introduction of regional regulations on plumbing invariance. Thanks to a numerical modeling of the groundwater flow, to the local scale of the site, it was possible to explore and simulate different possible solutions. The study initially required the reconstruction of the physical model of the subsoil and its geology and hydrogeology through research and consultation of the documentation available on the study area and its implementation within the software GMS, interface to the Modflow calculation code. Through the model it was able to evaluate several possible scenarios for the management of contamination (pumped groundwater reimmission, permeable reactive reactive - PRB). A particularly interesting aspect, even for the implications on remediation activities, is that the site is part of an area of widespread pollution for organochlorine solvents so, in addition to managing the contamination of the site, the system is exposed to external polluting loads.
ING I - Scuola di Ingegneria Civile, Ambientale e Territoriale
21-dic-2021
2020/2021
Il presente lavoro di tesi si inquadra nell’ambito degli studi sulla gestione dei siti contaminati e di valutazione degli interventi di bonifica e/o messa in sicurezza finalizzati a valutare e comparare diversi approcci e scenari d’intervento possibili. In particolare, la tesi affronta lo studio di un sito dove è attualmente in corso un intervento di pump and treat con recapito delle acque emunte in fognatura, in cui c’è l’interesse a individuare scenari alternativi di gestione delle acque emunte, anche alla luce dell’introduzione dei regolamenti regionali in tema di invarianza idraulica. Attraverso una modellazione numerica del flusso delle acque sotterranee, alla scala locale del sito, è stato possibile esplorare e simulare diverse possibili soluzioni. Lo studio ha richiesto inizialmente la ricostruzione del modello fisico del sottosuolo e della sua geologia e idrogeologia attraverso la ricerca e consultazione della documentazione disponibile sull’area di studio e la sua implementazione all’interno del software GMS, interfaccia al codice di calcolo Modflow. Attraverso il modello è stato possibile valutare diversi possibili scenari per la gestione della contaminazione (reimmissione delle acque emunte, barriera permeabile reattiva – PRB). Un aspetto particolarmente interessante che è emerso, anche per i risvolti sulle attività di bonifica, è il fatto che il sito si inserisce in un’area di inquinamento diffuso da solventi organoclorurati per cui, oltre a gestire la contaminazione del sito, l’impianto è esposto a carichi inquinanti esterni.
File allegati
File Dimensione Formato  
2021_12_Ratti.pdf

non accessibile

Dimensione 8.48 MB
Formato Adobe PDF
8.48 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/182003