The purpose of this paper is to analyse the energetic requalification of an existing building that is currently unused. This study, elaborated during a working experience at "Studio Planning" in Monza, has the purpose of carrying out an energy diagnosis, aimed at identifying the solutions that from a thermo-hygrometric point of view guarantee the respect of the law requirements related to the interventions of "relevant restructuring". The diagnosis of the energy needs of the building was carried out following the calculation provided by the UNI 11300 standard. The verifications of law are those dictated by the decrees DM 26/06/2015 and Dlgs n°28 of 03/03/2011. Subsequently, the thermal loads of the building will be studied in order to correctly size the newly installed technical systems, used for heating, cooling and ventilation services. A functional executive project of the technical systems will then be drawn up. It will be also studied the control logic of the plants and which are the necessary regulation choices in order to obtain the maximum efficiency of the plant also outside the nominal working conditions. The procedures listed above will be carried out following the standards and laws currently in force in the Lombardy Region and paying particular attention to the energy problem.

Il presente elaborato ha lo scopo di analizzare la ristrutturazione e la riqualificazione energetica di un edificio esistente attualmente non utilizzato. Questo studio, elaborato durante un’esperienza lavorativa presso lo "Studio Planning" di Monza, ha lo scopo di effettuare una diagnosi energetica, mirata ad individuare le soluzioni che da un punto di vista termo-igrometrico garantiscano il rispetto dei requisiti di legge relativi agli interventi di “ristrutturazione rilevante”. La diagnosi del fabbisogno energetico dell’edificio è stata effettuata seguendo il calcolo previsto dalla norma UNI 11300. Le verifiche di legge sono quelle dettate dai decreti DM 26/06/2015 e Dlgs n°28 del 03/03/2011. In seguito, verranno studiati i carichi termici dell’edificio al fine di dimensionare correttamente gli impianti tecnici di nuova installazione, adibiti ai servizi di riscaldamento, raffrescamento e ventilazione. Verrà quindi redatto un progetto esecutivo funzionale degli impianti tecnici. Sarà inoltre studiata la logica di controllo degli impianti e quali sono le scelte di regolazione necessarie per ottenere la massima efficienza dell'impianto anche al di fuori dalle condizioni nominali di lavoro. I procedimenti sopra elencati saranno sviluppati seguendo le norme e le leggi attualmente in vigore nella Regione Lombardia, e prestando particolare attenzione al problema ed al risparmio energetico.

Renovation of a commercial building : energy analysis and design of HVAC systems

Ceriani, Paolo
2020/2021

Abstract

The purpose of this paper is to analyse the energetic requalification of an existing building that is currently unused. This study, elaborated during a working experience at "Studio Planning" in Monza, has the purpose of carrying out an energy diagnosis, aimed at identifying the solutions that from a thermo-hygrometric point of view guarantee the respect of the law requirements related to the interventions of "relevant restructuring". The diagnosis of the energy needs of the building was carried out following the calculation provided by the UNI 11300 standard. The verifications of law are those dictated by the decrees DM 26/06/2015 and Dlgs n°28 of 03/03/2011. Subsequently, the thermal loads of the building will be studied in order to correctly size the newly installed technical systems, used for heating, cooling and ventilation services. A functional executive project of the technical systems will then be drawn up. It will be also studied the control logic of the plants and which are the necessary regulation choices in order to obtain the maximum efficiency of the plant also outside the nominal working conditions. The procedures listed above will be carried out following the standards and laws currently in force in the Lombardy Region and paying particular attention to the energy problem.
MARAZZI, GIAN LUIGI
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-dic-2021
2020/2021
Il presente elaborato ha lo scopo di analizzare la ristrutturazione e la riqualificazione energetica di un edificio esistente attualmente non utilizzato. Questo studio, elaborato durante un’esperienza lavorativa presso lo "Studio Planning" di Monza, ha lo scopo di effettuare una diagnosi energetica, mirata ad individuare le soluzioni che da un punto di vista termo-igrometrico garantiscano il rispetto dei requisiti di legge relativi agli interventi di “ristrutturazione rilevante”. La diagnosi del fabbisogno energetico dell’edificio è stata effettuata seguendo il calcolo previsto dalla norma UNI 11300. Le verifiche di legge sono quelle dettate dai decreti DM 26/06/2015 e Dlgs n°28 del 03/03/2011. In seguito, verranno studiati i carichi termici dell’edificio al fine di dimensionare correttamente gli impianti tecnici di nuova installazione, adibiti ai servizi di riscaldamento, raffrescamento e ventilazione. Verrà quindi redatto un progetto esecutivo funzionale degli impianti tecnici. Sarà inoltre studiata la logica di controllo degli impianti e quali sono le scelte di regolazione necessarie per ottenere la massima efficienza dell'impianto anche al di fuori dalle condizioni nominali di lavoro. I procedimenti sopra elencati saranno sviluppati seguendo le norme e le leggi attualmente in vigore nella Regione Lombardia, e prestando particolare attenzione al problema ed al risparmio energetico.
File allegati
File Dimensione Formato  
2021_12_Ceriani.pdf

non accessibile

Dimensione 4.25 MB
Formato Adobe PDF
4.25 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/182105