Hypertension represents an important risk factor for cardiovascular diseases and denotes the level of blood pressure at which a treatment is strictly necessary. Most of hypertensive people are not aware of it and show symptoms that are too generic to be directly associated with hypertension and go unnoticed. Thus, it is crucial to identify the measurement technique and modality that better detect abnormal blood pressure values. Moreover, to have a good comprehension of blood pressure measurement it is necessary to study it together with other vital parameters. The present study analyzes the devices currently proposed on the market, as well as the state of the art of the techniques employed to measure arterial blood pressure, with specific interest to the practical research of the most suitable monitor to be integrated into a multiparametric wearable device given by L.I.F.E. Italia Srl. Four oscillometric devices were selected from the state of the art and market analysis: three from home blood pressure monitoring and one watch-type monitor. Their accuracy was assessed through a specific validation protocol involving 14 subjects performing aerobic exercises to increase their blood pressure, using a validated ambulatory blood pressure monitor as reference. Evaluation of accuracy, connectivity, wearability, and cost highlighted the differences in the groups: watch-type devices are not accurate enough, while the others resulted to be less connectable and wearable. Based on the results, several integration solutions are presented, with technical and practical considerations on the actual implementation.

L’ipertensione è definita come il livello di pressione sanguigna per il quale un trattamento è strettamente necessario, e rappresenta un importante fattore di rischio per le malattie cardiovascolari. La maggior parte dei pazienti ipertensivi non è consapevole di esserne affetto e mostra sintomi troppo generici per poter essere associati all’ipertensione, così da finire ignorati. Risulta di fondamentale importanza identificare quali tecniche e modalità di misura della pressione arteriosa siano in grado di rilevare efficacemente situazioni patologiche. Inoltre, per comprendere a pieno la misura di pressione arteriosa, è necessario rapportarla ad altri parametri fisiologici misurati contemporaneamente. Questo studio analizza i dispositivi attualmente presenti sul mercato, così come lo stato dell’arte delle tecniche impiegate per misurare la pressione, con interesse specifico alla ricerca di un dispositivo da integrare all’interno di un sistema wearable multi-parametrico prodotto da L.I.F.E. Italia Srl. A questo scopo, quattro dispositivi oscillometrici sono stati selezionati dall’analisi effettuata: tre dispositivi della categoria Home Blood Pressure Monitoring e un dispositivo watch-type. La loro accuratezza è stata determinata tramite un protocollo di validazione interna, che ha coinvolto 14 soggetti che hanno svolto attività aerobica per incrementare la loro pressione arteriosa e usando uno sfigmomanometro automatico validato come riferimento. È stata svolta un’indagine anche a livello di connettività, vestibilità e costo, la quale ha evidenziato diverse differenze tra i gruppi. I dispositivi watch-type sono risultati essere inaccurati, mentre gli altri si sono dimostrati più carenti a livello di integrabilità e vestibilità. Sulla base dei risultati sono state proposte diverse soluzioni di integrazione, insieme a considerazioni pratiche e tecniche sulle implementazioni vere e proprie.

Comparison of smart blood pressure monitors for the integration into a wearable multi-parametric device : market analysis and technical evaluation

DUSI, LORENZO
2020/2021

Abstract

Hypertension represents an important risk factor for cardiovascular diseases and denotes the level of blood pressure at which a treatment is strictly necessary. Most of hypertensive people are not aware of it and show symptoms that are too generic to be directly associated with hypertension and go unnoticed. Thus, it is crucial to identify the measurement technique and modality that better detect abnormal blood pressure values. Moreover, to have a good comprehension of blood pressure measurement it is necessary to study it together with other vital parameters. The present study analyzes the devices currently proposed on the market, as well as the state of the art of the techniques employed to measure arterial blood pressure, with specific interest to the practical research of the most suitable monitor to be integrated into a multiparametric wearable device given by L.I.F.E. Italia Srl. Four oscillometric devices were selected from the state of the art and market analysis: three from home blood pressure monitoring and one watch-type monitor. Their accuracy was assessed through a specific validation protocol involving 14 subjects performing aerobic exercises to increase their blood pressure, using a validated ambulatory blood pressure monitor as reference. Evaluation of accuracy, connectivity, wearability, and cost highlighted the differences in the groups: watch-type devices are not accurate enough, while the others resulted to be less connectable and wearable. Based on the results, several integration solutions are presented, with technical and practical considerations on the actual implementation.
ALIVERTI, ANDREA
CORNA, LUCA
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-dic-2021
2020/2021
L’ipertensione è definita come il livello di pressione sanguigna per il quale un trattamento è strettamente necessario, e rappresenta un importante fattore di rischio per le malattie cardiovascolari. La maggior parte dei pazienti ipertensivi non è consapevole di esserne affetto e mostra sintomi troppo generici per poter essere associati all’ipertensione, così da finire ignorati. Risulta di fondamentale importanza identificare quali tecniche e modalità di misura della pressione arteriosa siano in grado di rilevare efficacemente situazioni patologiche. Inoltre, per comprendere a pieno la misura di pressione arteriosa, è necessario rapportarla ad altri parametri fisiologici misurati contemporaneamente. Questo studio analizza i dispositivi attualmente presenti sul mercato, così come lo stato dell’arte delle tecniche impiegate per misurare la pressione, con interesse specifico alla ricerca di un dispositivo da integrare all’interno di un sistema wearable multi-parametrico prodotto da L.I.F.E. Italia Srl. A questo scopo, quattro dispositivi oscillometrici sono stati selezionati dall’analisi effettuata: tre dispositivi della categoria Home Blood Pressure Monitoring e un dispositivo watch-type. La loro accuratezza è stata determinata tramite un protocollo di validazione interna, che ha coinvolto 14 soggetti che hanno svolto attività aerobica per incrementare la loro pressione arteriosa e usando uno sfigmomanometro automatico validato come riferimento. È stata svolta un’indagine anche a livello di connettività, vestibilità e costo, la quale ha evidenziato diverse differenze tra i gruppi. I dispositivi watch-type sono risultati essere inaccurati, mentre gli altri si sono dimostrati più carenti a livello di integrabilità e vestibilità. Sulla base dei risultati sono state proposte diverse soluzioni di integrazione, insieme a considerazioni pratiche e tecniche sulle implementazioni vere e proprie.
File allegati
File Dimensione Formato  
Dusi_Lorenzo_939955.pdf

non accessibile

Descrizione: Tesi Dusi Lorenzo
Dimensione 5.63 MB
Formato Adobe PDF
5.63 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/182616