The aim of the thesis is to analyze the energy consumption of the complex of laboratories Power lab and Experience lab and then propose and implement a system to manage energy and reduce energy consumption knowing that the greater consumption comes from the tests of short circuit. After a validation process of the measurements, an energy analysis was car-ried out of the consumption of the motors that regulate the speed of the alternators at different speeds. With the data obtained from this analysis, the behavior of the machines has been de-fined. A plc program has been developed with the obtained data to manage the consumption of the alternators when they are not used. Then the possibility of turning off the dynamo was evaluated to further smooth out the consumption due to short-circuit tests. In the Experience lab, an energy analysis was carried out with the aim of envying the loads that absorb more energy and evaluating a system to manage these loads to reduce the con-sumption related to them. After a validation process of the measurements, the compressor was identified as the most energy-intensive load. After an analysis of the current consump-tion ,it was possible to calculated the consumption related to the number of compressor starts during a working day and the consumption that you would have by installing an inverter in the same period of time with the same loads.

Lo scopo della tesi è quello di analizzare il consumo energetico del complesso di laboratori Power lab ed Experience lab e successivamente di proporre e implementare un sistema per gestire l’energia e ridurre i consumi energetici sapendo che il consumo maggiore deriva dalle prove di corto circuito. Dopo un processo di validazione delle misure è stato svolta un’analisi energetica dei consumi dei motori che regolano la velocità degli alternatori a differenti veloci-tà. Con i dati ricavati da questa analisi è stato definito il comportamento delle macchine, ed è stato sviluppato un programma plc per gestire i consumi degli alternatori quando essi non vengono impiegati. Successivamente è stata valutata la possibilità di spegnere anche la dina-mo per limare ulteriormente i consumi dovuti ai test di corto circuito. Nell Experience lab è stata svolta un’analisi energetica con lo scopo di andare ad invidiare i carichi che assorbono più energia e di valutare un sistema per gestire gli stessi con lo scopo di ridurre i consumi ad essi legati. Dopo un processo di validazione delle misure è stato individuato il compressore come carico più energivoro e dopo un’analisi degli assorbimenti è stato calcolato il consumo legato al numero di avviamenti del compressore durante una giornata lavorativa e il consumo che si avrebbe installando un inverter nello stesso periodo di tempo con gli stessi carichi.

Ottimizzazione dei consumi energetici del laboratorio prove ABB SACE Bergamo

COTUGNO, LORIS
2022/2023

Abstract

The aim of the thesis is to analyze the energy consumption of the complex of laboratories Power lab and Experience lab and then propose and implement a system to manage energy and reduce energy consumption knowing that the greater consumption comes from the tests of short circuit. After a validation process of the measurements, an energy analysis was car-ried out of the consumption of the motors that regulate the speed of the alternators at different speeds. With the data obtained from this analysis, the behavior of the machines has been de-fined. A plc program has been developed with the obtained data to manage the consumption of the alternators when they are not used. Then the possibility of turning off the dynamo was evaluated to further smooth out the consumption due to short-circuit tests. In the Experience lab, an energy analysis was carried out with the aim of envying the loads that absorb more energy and evaluating a system to manage these loads to reduce the con-sumption related to them. After a validation process of the measurements, the compressor was identified as the most energy-intensive load. After an analysis of the current consump-tion ,it was possible to calculated the consumption related to the number of compressor starts during a working day and the consumption that you would have by installing an inverter in the same period of time with the same loads.
ING - Scuola di Ingegneria Industriale e dell'Informazione
5-ott-2023
2022/2023
Lo scopo della tesi è quello di analizzare il consumo energetico del complesso di laboratori Power lab ed Experience lab e successivamente di proporre e implementare un sistema per gestire l’energia e ridurre i consumi energetici sapendo che il consumo maggiore deriva dalle prove di corto circuito. Dopo un processo di validazione delle misure è stato svolta un’analisi energetica dei consumi dei motori che regolano la velocità degli alternatori a differenti veloci-tà. Con i dati ricavati da questa analisi è stato definito il comportamento delle macchine, ed è stato sviluppato un programma plc per gestire i consumi degli alternatori quando essi non vengono impiegati. Successivamente è stata valutata la possibilità di spegnere anche la dina-mo per limare ulteriormente i consumi dovuti ai test di corto circuito. Nell Experience lab è stata svolta un’analisi energetica con lo scopo di andare ad invidiare i carichi che assorbono più energia e di valutare un sistema per gestire gli stessi con lo scopo di ridurre i consumi ad essi legati. Dopo un processo di validazione delle misure è stato individuato il compressore come carico più energivoro e dopo un’analisi degli assorbimenti è stato calcolato il consumo legato al numero di avviamenti del compressore durante una giornata lavorativa e il consumo che si avrebbe installando un inverter nello stesso periodo di tempo con gli stessi carichi.
File allegati
File Dimensione Formato  
2023_10_Cotugno.pdf

non accessibile

Dimensione 2.52 MB
Formato Adobe PDF
2.52 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/210473