The goal of this thesis is to find the best fire prevention solutions for Villa Matteotti in Dolo, respecting all the current regulations in Italy while also attempting to reduce costs as much as possible. After a brief historical contextualization of the villa in question, each point of section S of the Fire Prevention Code regarding the Fire Strategy is addressed one by one, and concurrently, the vertical technical rule V10, published in 2020 by the Minister of the Interior, is applied to the case study. In the following technical report, all the solutions adopted for the villa are explained in detail with particular attention to the extinguishing gas fire suppression system adopted for the basement, where an archive will be located. Finally, significant importance was given to computational fluid dynamics modeling using various software since this is one of the strengths of the master’s degree in engineering for prevention and safety in the process industry; moreover, it was precisely the modeling that allowed highlighting the limits of some adopted solutions and finding more effective alternatives. In particular, the software adopted for the fire simulation is FDS while for evacuation Pathfinder has been used. The fundamental desire with which the following thesis was written is to regulate the villa while trying to respect its history, art, and architecture as much as possible.

L’obiettivo di questa tesi è quella di trovare le migliori soluzioni antincendio per Villa Matteotti di Dolo rispettando tutte le normative vigenti in Italia e cercando al contempo di ridurre i costi il più possibile. Dopo una rapida contestualizzazione storica della villa in oggetto, si affrontano uno ad uno tutti i punti della sezione S del Codice di Prevenzione Incendi riguardo la Strategia Antincendio, e contestualmente, viene applicata al caso in esame anche la regola tecnica verticale V10, pubblicata nel 2020 dal Ministro dell’Interno. Nella seguente tesi tecnica si cercano di spiegare nel dettaglio tutte le soluzioni adottate per la villa con una particolare attenzione al sistema di spegnimento dell’incendio a gas estinguente adottato per il seminterrato, dove sarà presente un archivio. Si è cercato, infine, di dare molta importanza alla modellazione fluidodinamica utilizzando diversi software poiché questo è uno dei punti di forza della laurea magistrale in Ingegneria della Prevenzione e Sicurezza nell’Industria di Processo; inoltre, è stata proprio la modellazione, che ha permesso di evidenziare i limiti di alcune soluzioni adottate e di trovare delle alternative più efficaci. Nello specifico per la modellazione del fuoco si è usato il software FDS mentre per l’evacuazione il software Pathfinder. Il desiderio di base con cui è stata scritta la seguente tesi è quello di mettere a norma la villa cercando però di rispettarne il più possibile la storia, l’arte e l’architettura.

Progettazione preliminare e analisi prestazionale di un impianto antincendio per una villa veneta

Renzi, Alessandra
2022/2023

Abstract

The goal of this thesis is to find the best fire prevention solutions for Villa Matteotti in Dolo, respecting all the current regulations in Italy while also attempting to reduce costs as much as possible. After a brief historical contextualization of the villa in question, each point of section S of the Fire Prevention Code regarding the Fire Strategy is addressed one by one, and concurrently, the vertical technical rule V10, published in 2020 by the Minister of the Interior, is applied to the case study. In the following technical report, all the solutions adopted for the villa are explained in detail with particular attention to the extinguishing gas fire suppression system adopted for the basement, where an archive will be located. Finally, significant importance was given to computational fluid dynamics modeling using various software since this is one of the strengths of the master’s degree in engineering for prevention and safety in the process industry; moreover, it was precisely the modeling that allowed highlighting the limits of some adopted solutions and finding more effective alternatives. In particular, the software adopted for the fire simulation is FDS while for evacuation Pathfinder has been used. The fundamental desire with which the following thesis was written is to regulate the villa while trying to respect its history, art, and architecture as much as possible.
ING - Scuola di Ingegneria Industriale e dell'Informazione
9-apr-2024
2022/2023
L’obiettivo di questa tesi è quella di trovare le migliori soluzioni antincendio per Villa Matteotti di Dolo rispettando tutte le normative vigenti in Italia e cercando al contempo di ridurre i costi il più possibile. Dopo una rapida contestualizzazione storica della villa in oggetto, si affrontano uno ad uno tutti i punti della sezione S del Codice di Prevenzione Incendi riguardo la Strategia Antincendio, e contestualmente, viene applicata al caso in esame anche la regola tecnica verticale V10, pubblicata nel 2020 dal Ministro dell’Interno. Nella seguente tesi tecnica si cercano di spiegare nel dettaglio tutte le soluzioni adottate per la villa con una particolare attenzione al sistema di spegnimento dell’incendio a gas estinguente adottato per il seminterrato, dove sarà presente un archivio. Si è cercato, infine, di dare molta importanza alla modellazione fluidodinamica utilizzando diversi software poiché questo è uno dei punti di forza della laurea magistrale in Ingegneria della Prevenzione e Sicurezza nell’Industria di Processo; inoltre, è stata proprio la modellazione, che ha permesso di evidenziare i limiti di alcune soluzioni adottate e di trovare delle alternative più efficaci. Nello specifico per la modellazione del fuoco si è usato il software FDS mentre per l’evacuazione il software Pathfinder. Il desiderio di base con cui è stata scritta la seguente tesi è quello di mettere a norma la villa cercando però di rispettarne il più possibile la storia, l’arte e l’architettura.
File allegati
File Dimensione Formato  
2024_04_Renzi_Executive Summary_02.pdf

non accessibile

Dimensione 709.18 kB
Formato Adobe PDF
709.18 kB Adobe PDF   Visualizza/Apri
2024_04_Renzi_Tesi_01.pdf

non accessibile

Dimensione 4.89 MB
Formato Adobe PDF
4.89 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/217976