The Primary Heat eXchanger (PHX) development is a crucial aspect in the MYRRHA (Multi-purpose HYbrid Research Reactor for High-tech Applications) reactor's design. SCK CEN researchers performed an experimental investigation, using a scaled facility known as Table Top, targeting what concerns its thermal behavior to obtain first-order estimates of the key parameters (e.g. the thermal resistance of the double tube) and define procedures that will be used later in the large-scale facilities. Table Top is an open-loop water/steam facility with a 2.5 kW maximum power that operates under natural convection flow. It can be operated within a pressure range of 8 to 16 bara. This work aims to review and update the TH system code nodalization representing the Table Top facility providing the conceptual basis to obtain a qualified nodalization which is specific for non nuclear facilities. This process is described in a general way and it ispotentially applicable to other SCK CEN facilities that requires a TH system code nodalization. To this purpose simulations are performed with a System Thermal Hydraulic code (RELAP5 3.3) to assess the robustness of the qualification procedure. The document is structured into nine primary chapters and two attached appendixes. The first three chapters are introductory sections. Chapter one outlines the objectives, scope, and significance of the study. Section two delves into the necessary literature review. Section three describes the Table Top installation. Section four describes the qualification procedure in a general way. Sections from five to eight constitute the core of this work by providing: • A description of the un-qualified TH system code nodalization of Table Top (section five) • Application of the general procedure to Table Top case up to step 14 (section six) • A description of the qualified TH system code nodalization of Table Top (section seven) • Application of the general procedure from step 15 to 17 (section eight) The final chapter summarizes the findings and discusses the implications of the study. The two attached appendixes deal with Hydraulic handbook (appendix A) and thermal handbook (appendix B) of the qualified nodalization.

Lo sviluppo dello scambiatore termico primario (PHX) è un aspetto cruciale nella progettazione del reattore MYRRHA (Multi-purpose HYbrid Research Reactor for High-tech Applications). I ricercatori del SCK CEN hanno condotto un'indagine sperimentale, utilizzando un impianto in scala noto come Table Top, circa le proprietà termiche e meccaniche del PHX ed effettuando test per ottenere stime di primo ordine dei parametri chiave (ad esempio il coefficiente di trasferimento di calore dello scambiatore) e definire le procedure che saranno utilizzate in seguito negli impianti su larga scala. Table Top è un impianto acqua/vapore a ciclo aperto con una capacità di 2,5 kW che opera in regime di circolazione naturale. Funziona in un intervallo di pressione compreso tra 8 e 16 bara. Questo lavoro è volto all’aggiornamento del codice TH che rappresenta l'impianto, fornendo la base concettuale per un processo di qualificazione dell'impianto che possa essere utilizzato anche in altri impianti di SCK CEN. A questo scopo sono state eseguite diverse simulazioni con un codice termoidraulico di sistema (RELAP5 3.3) al fine di valutare la robustezza della procedura di qualificazione e implementarne il codice di riferimento.

Analysis of table top experiments by means of thermal hydraulic system code

DIKONIMOS MAKRIS, LOUKAS
2023/2024

Abstract

The Primary Heat eXchanger (PHX) development is a crucial aspect in the MYRRHA (Multi-purpose HYbrid Research Reactor for High-tech Applications) reactor's design. SCK CEN researchers performed an experimental investigation, using a scaled facility known as Table Top, targeting what concerns its thermal behavior to obtain first-order estimates of the key parameters (e.g. the thermal resistance of the double tube) and define procedures that will be used later in the large-scale facilities. Table Top is an open-loop water/steam facility with a 2.5 kW maximum power that operates under natural convection flow. It can be operated within a pressure range of 8 to 16 bara. This work aims to review and update the TH system code nodalization representing the Table Top facility providing the conceptual basis to obtain a qualified nodalization which is specific for non nuclear facilities. This process is described in a general way and it ispotentially applicable to other SCK CEN facilities that requires a TH system code nodalization. To this purpose simulations are performed with a System Thermal Hydraulic code (RELAP5 3.3) to assess the robustness of the qualification procedure. The document is structured into nine primary chapters and two attached appendixes. The first three chapters are introductory sections. Chapter one outlines the objectives, scope, and significance of the study. Section two delves into the necessary literature review. Section three describes the Table Top installation. Section four describes the qualification procedure in a general way. Sections from five to eight constitute the core of this work by providing: • A description of the un-qualified TH system code nodalization of Table Top (section five) • Application of the general procedure to Table Top case up to step 14 (section six) • A description of the qualified TH system code nodalization of Table Top (section seven) • Application of the general procedure from step 15 to 17 (section eight) The final chapter summarizes the findings and discusses the implications of the study. The two attached appendixes deal with Hydraulic handbook (appendix A) and thermal handbook (appendix B) of the qualified nodalization.
Rozzia, Davide
ING - Scuola di Ingegneria Industriale e dell'Informazione
11-dic-2024
2023/2024
Lo sviluppo dello scambiatore termico primario (PHX) è un aspetto cruciale nella progettazione del reattore MYRRHA (Multi-purpose HYbrid Research Reactor for High-tech Applications). I ricercatori del SCK CEN hanno condotto un'indagine sperimentale, utilizzando un impianto in scala noto come Table Top, circa le proprietà termiche e meccaniche del PHX ed effettuando test per ottenere stime di primo ordine dei parametri chiave (ad esempio il coefficiente di trasferimento di calore dello scambiatore) e definire le procedure che saranno utilizzate in seguito negli impianti su larga scala. Table Top è un impianto acqua/vapore a ciclo aperto con una capacità di 2,5 kW che opera in regime di circolazione naturale. Funziona in un intervallo di pressione compreso tra 8 e 16 bara. Questo lavoro è volto all’aggiornamento del codice TH che rappresenta l'impianto, fornendo la base concettuale per un processo di qualificazione dell'impianto che possa essere utilizzato anche in altri impianti di SCK CEN. A questo scopo sono state eseguite diverse simulazioni con un codice termoidraulico di sistema (RELAP5 3.3) al fine di valutare la robustezza della procedura di qualificazione e implementarne il codice di riferimento.
File allegati
File Dimensione Formato  
2024_12_DikonimosMakris_Tesi.pdf

accessibile in internet per tutti

Descrizione: thesis
Dimensione 7.46 MB
Formato Adobe PDF
7.46 MB Adobe PDF Visualizza/Apri
2024_12_DikonimosMakris_executivesummary.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: executive summary
Dimensione 1.13 MB
Formato Adobe PDF
1.13 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/231313