In the context of urbanization causing flooding and the urban heat island effect in Ho Chi Minh City, this study proposes a retrofitting strategy for existing buildings to adapt to green infrastructure. Using the UAH Campus as a case study, the thesis employs energy simulation to propose several interventions: optimizing the building envelope for better ventilation, integrating a rainwater harvesting system, and implementing green roofs. The results indicate significant improvements in the microclimate, along with reductions in electricity consumption and CO2 emissions. The project not only creates a comfortable learning environment but also establishes a replicable model, contributing to the city's sustainable urban development roadmap.
Nel contesto dell'urbanizzazione che causa inondazioni e l'effetto isola di calore urbano a Ho Chi Minh City, questo studio propone una strategia di riqualificazione degli edifici esistenti per adattarli alle infrastrutture verdi. Utilizzando il Campus UAH come caso di studio, la tesi impiega la simulazione energetica per proporre diverse soluzioni: l'ottimizzazione dell'involucro edilizio per favorire la ventilazione, l'integrazione di un sistema di raccolta delle acque meteoriche e la realizzazione di tetti verdi. I risultati mostrano un significativo miglioramento del microclima, insieme a una riduzione del consumo di elettricità e delle emissioni di CO2. Il progetto non solo crea un ambiente di apprendimento confortevole, ma rappresenta anche un modello replicabile, contribuendo al percorso di sviluppo urbano sostenibile della città.
Upgrading existing buildings towards sustainability in the context of Ho Chi Minh's city urban growth : case study: UAH Campus
NGUYEN, CONG KHANH
2025/2026
Abstract
In the context of urbanization causing flooding and the urban heat island effect in Ho Chi Minh City, this study proposes a retrofitting strategy for existing buildings to adapt to green infrastructure. Using the UAH Campus as a case study, the thesis employs energy simulation to propose several interventions: optimizing the building envelope for better ventilation, integrating a rainwater harvesting system, and implementing green roofs. The results indicate significant improvements in the microclimate, along with reductions in electricity consumption and CO2 emissions. The project not only creates a comfortable learning environment but also establishes a replicable model, contributing to the city's sustainable urban development roadmap.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_03_Nguyen_Thesis Booklet_01.pdf
non accessibile
Descrizione: Booklet
Dimensione
103.64 MB
Formato
Adobe PDF
|
103.64 MB | Adobe PDF | Visualizza/Apri |
|
2026_03_Nguyen_A1 Panel_01.pdf
non accessibile
Descrizione: A1 Panel_Page 01-02
Dimensione
80.22 MB
Formato
Adobe PDF
|
80.22 MB | Adobe PDF | Visualizza/Apri |
|
2026_03_Nguyen_A1 Panel_02.pdf
non accessibile
Descrizione: A1 Panel_Page 03-04
Dimensione
90.5 MB
Formato
Adobe PDF
|
90.5 MB | Adobe PDF | Visualizza/Apri |
|
2026_03_Nguyen_A1 Panel_03.pdf
non accessibile
Descrizione: A1 Panel_Page 05-06
Dimensione
102.95 MB
Formato
Adobe PDF
|
102.95 MB | Adobe PDF | Visualizza/Apri |
|
2026_03_Nguyen_A1 Panel_04.pdf
non accessibile
Descrizione: A1 Panel_Page 07-08
Dimensione
92.8 MB
Formato
Adobe PDF
|
92.8 MB | Adobe PDF | Visualizza/Apri |
|
2026_03_Nguyen_A1 Panel_05.pdf
non accessibile
Descrizione: A1 Panel_Page 09-10
Dimensione
132.4 MB
Formato
Adobe PDF
|
132.4 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/251745