In the present work were considered some actions to be carried out under renovation, to increase the energy efficiency of residential building. Have defined the most popular design features in the area of the Po Valley and developed a study about an insulation intervention. For the plant were analyzed small scale solar cooling systems available on Italian market and some type of direct flow solar collector were compared. Define the connections between solar field and heat engine, some simulation was performed to verify the performance of the solar field using the software TSOL. The results for the intervention of insulation represents an increase of efficiency of the housing and in some cases allow an increase in the energy class of the building; practical advantages due to the method of action, shall be aggregated with energy advantages. The examination of the solar cooling system describes the technology as promising in terms of energy but unsustainable economically.

Nel presente lavoro di tesi sono stati considerati alcuni interventi, da eseguire in fase di ristrutturazione, per incrementare l’efficienza energetica degli edifici ad uso residenziale. Sono state definite le caratteristiche costruttive più diffuse nella zona della pianura padana e sviluppato uno studio su un intervento di coibentazione. Per la parte impiantistica sono stati analizzati i sistemi di solar cooling di piccola taglia attualmente disponibili sul mercato sono stati eseguiti dei confronti fra collettori solari a tubi sottovuoto a flusso diretto. Definiti gli accoppiamenti fra campo solare e macchina termica è stato eseguita una simulazione per verificare le performance del campo solare tramite il software TSOL. I risultati relativi all’intervento di coibentazione denotano un incremento dell’efficienza dell’involucro e in alcuni casi permettono un incremento della classe energetica dell’edificio; vantaggi di tipo pratico, dovuti alla metodica d’intervento, si sommano a quelli energetici. L’analisi relativa al sistema di solar cooling descrive questa tecnologia come promettente dal punto di vista energetico ma ancora insostenibile dal punto di vista economico.

Ristrutturazione di edifici residenziali. Ipotesi di intervento per la riduzione del fabbisogno energetico e analisi di un sistema solare termico per il raffrescamento estivo e la produzione di acqua calda sanitaria

PASINI, ALESSANDRO
2009/2010

Abstract

In the present work were considered some actions to be carried out under renovation, to increase the energy efficiency of residential building. Have defined the most popular design features in the area of the Po Valley and developed a study about an insulation intervention. For the plant were analyzed small scale solar cooling systems available on Italian market and some type of direct flow solar collector were compared. Define the connections between solar field and heat engine, some simulation was performed to verify the performance of the solar field using the software TSOL. The results for the intervention of insulation represents an increase of efficiency of the housing and in some cases allow an increase in the energy class of the building; practical advantages due to the method of action, shall be aggregated with energy advantages. The examination of the solar cooling system describes the technology as promising in terms of energy but unsustainable economically.
ING IV - Facolta' di Ingegneria Industriale
21-lug-2010
2009/2010
Nel presente lavoro di tesi sono stati considerati alcuni interventi, da eseguire in fase di ristrutturazione, per incrementare l’efficienza energetica degli edifici ad uso residenziale. Sono state definite le caratteristiche costruttive più diffuse nella zona della pianura padana e sviluppato uno studio su un intervento di coibentazione. Per la parte impiantistica sono stati analizzati i sistemi di solar cooling di piccola taglia attualmente disponibili sul mercato sono stati eseguiti dei confronti fra collettori solari a tubi sottovuoto a flusso diretto. Definiti gli accoppiamenti fra campo solare e macchina termica è stato eseguita una simulazione per verificare le performance del campo solare tramite il software TSOL. I risultati relativi all’intervento di coibentazione denotano un incremento dell’efficienza dell’involucro e in alcuni casi permettono un incremento della classe energetica dell’edificio; vantaggi di tipo pratico, dovuti alla metodica d’intervento, si sommano a quelli energetici. L’analisi relativa al sistema di solar cooling descrive questa tecnologia come promettente dal punto di vista energetico ma ancora insostenibile dal punto di vista economico.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2010_07_Pasini.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Testo Della Tesi
Dimensione 4.4 MB
Formato Adobe PDF
4.4 MB Adobe PDF   Visualizza/Apri