Fire reduces the strength and the stiffness of structural materials with rising temperature. The design of structures in fire requires showing that, for a given fire duration, the structure still carries the applied loads. Finite element softwares such as SAFIR are widely used to predict this behaviour, returning detailed per-fibre data (temperature, geometry, stress) for every cross-section at every time step. The raw output files cannot be used directly for a sectional check. This thesis develops a design-oriented post-processing tool that closes this gap. The tool has two parts. The first reads the SAFIR .OUT and .TEM files and produces a structured Excel workbook with the per-fibre data at the standard Eurocode fire durations. The second computes the M-N capacity of the section at each fire duration using an equilibrium-based approach: for a prescribed axial force N, the curvature κ is swept from zero upward, and at every step a reference strain ε₀ is found by an inner Newton-Raphson iteration so that equilibrium is satis-fied. The peak of the M-versus-κ curve gives the maximum bending moment Mmax. Two con-stitutive laws are implemented for each material: the full nonlinear law from the Eurocodes and a simplified fully plastic version. The procedure was applied to five cross-sections. For a steel column under N = 2000 kN, the solver stops converging at about 85 minutes, matching the failure time reported by SAFIR. Four reinforced-concrete sections were then studied under N = 500 kN. A 300 × 600 mm beam exposed to fire on three sides loses bending capacity from 488 to 163 kN·m over 240 minutes. A T-section keeps a long lever arm, because the flange stays cool, so its loss over two hours is about 38%. A rectangular section loses about half of its capacity over three hours. A one-way slab strip heated only from below retains about 91% of its capacity at three hours, because only the bottom bar and a thin layer of concrete reach high temperature. The gap between the non-linear law and the fully plastic law stays below 6% for the steel column and for the T, rectan-gular and slab sections, and reaches 19% for the 300 × 600 beam, where the rising branch of the parabolic concrete law carries a larger share of the compression. Because the axial force is a single input, sweeping it over a range gives the full M-N interaction envelope at each fire time. This is the basis for judging whether the axial force that builds up in a restrained member under fire is favourable or unfavourable for its bending capacity. The tool is general and works for any cross-section modelled within the SAFIR. The post-pro-cessing code was developed with the help of an AI assistant, and testing how well such a tool can turn an engineering objective into working code was itself one of the aims of the work.

L’incendio riduce la resistenza e la rigidezza dei materiali strutturali all’aumentare della tem-peratura. La verifica di una struttura in condizioni di incendio richiede di dimostrare che, per una assegnata durata di incendio, la struttura sia ancora in grado di sopportare i carichi ap-plicati. Software agli elementi finiti come SAFIR sono molto usati per modellare questo com-portamento, restituendo dati dettagliati per ogni fibra della sezione (temperatura, geometria, sforzo) ad ogni istante dell’analisi. I file di output grezzi, tuttavia, non possono essere usati direttamente per una verifica sezionale. Questa tesi sviluppa uno strumento di post-elaborazione orientato alla progettazione che colma questa lacuna. Lo strumento si compone di due parti. La prima legge i file SAFIR .OUT e .TEM e produce un file Excel strutturato con i dati per fibra alle durate di incendio standard degli Eurocodici. La seconda calcola la capacità M-N della sezione per ogni durata di incendio con un approccio basato sull’equilibrio: fissata l’azione assiale N, la curvatura κ viene incrementata da zero e, ad ogni passo, la deformazione di riferimento ε₀ viene trovata tramite il metodo di Newton-Raphson imponendo l’equilibrio. Il picco della curva M-κ fornisce il momento flet-tente massimo Mmax. Per ogni materiale sono implementate due leggi costitutive: quella non lineare completa degli Eurocodici e una versione perfettamente plastica. Il metodo è stato applicato a cinque sezioni. Per una colonna in acciaio con N = 2000 kN, il calcolo non converge intorno a 85 minuti, in accordo con il tempo di collasso riportato da SAFIR. Sono state poi studiate quattro sezioni in cemento armato con N = 500 kN. Una trave 300 × 600 mm esposta al fuoco su tre lati perde capacità flessionale da 488 a 163 kN·m nell’arco di 240 minuti. Una sezione a T mantiene un braccio di leva elevato, perché la soletta resta fredda, e la sua perdita in due ore è di circa il 38%. Una sezione rettangolare perde circa metà della sua capacità in tre ore. Una striscia di soletta riscaldata solo dal basso conserva circa il 91% della capacità a tre ore, perché solo la barra inferiore e un sottile strato di calcestruzzo raggiungono temperature elevate. Lo scarto tra la legge non lineare e quella completamente plastica resta sotto il 6% per la colonna in acciaio e per le sezioni a T, rettangolare e a soletta, e arriva al 19% per la trave 300 × 600, dove il ramo crescente della legge parabolica del cal-cestruzzo contribuisce maggiormente alla capacità a compressione. Poiché l’azione assiale è un singolo dato di ingresso, facendola variare su un intervallo si ot-tiene l’intero dominio di interazione M-N per ogni durata di incendio. Questa è la base per giudicare se l’incremento di forza assiale che si sviluppa in un elemento vincolato durante l’in-cendio sia favorevole o sfavorevole per la sua capacità flessionale. Lo strumento è generale e funziona per qualsiasi sezione che SAFIR sia in grado di trattare. Il codice di post-elaborazione è stato sviluppato con l'aiuto dell' intelligenza artificiale, e verificare quanto un simile stru-mento riesca a trasformare un obiettivo ingegneristico in codice funzionante è stato esso stesso uno degli scopi del presente lavoro di tesi.

Development of a design-oriented tool for structural members exposed to fire

Pandit, Adarsh Ashok;PALANI, SHIVSAGAR
2025/2026

Abstract

Fire reduces the strength and the stiffness of structural materials with rising temperature. The design of structures in fire requires showing that, for a given fire duration, the structure still carries the applied loads. Finite element softwares such as SAFIR are widely used to predict this behaviour, returning detailed per-fibre data (temperature, geometry, stress) for every cross-section at every time step. The raw output files cannot be used directly for a sectional check. This thesis develops a design-oriented post-processing tool that closes this gap. The tool has two parts. The first reads the SAFIR .OUT and .TEM files and produces a structured Excel workbook with the per-fibre data at the standard Eurocode fire durations. The second computes the M-N capacity of the section at each fire duration using an equilibrium-based approach: for a prescribed axial force N, the curvature κ is swept from zero upward, and at every step a reference strain ε₀ is found by an inner Newton-Raphson iteration so that equilibrium is satis-fied. The peak of the M-versus-κ curve gives the maximum bending moment Mmax. Two con-stitutive laws are implemented for each material: the full nonlinear law from the Eurocodes and a simplified fully plastic version. The procedure was applied to five cross-sections. For a steel column under N = 2000 kN, the solver stops converging at about 85 minutes, matching the failure time reported by SAFIR. Four reinforced-concrete sections were then studied under N = 500 kN. A 300 × 600 mm beam exposed to fire on three sides loses bending capacity from 488 to 163 kN·m over 240 minutes. A T-section keeps a long lever arm, because the flange stays cool, so its loss over two hours is about 38%. A rectangular section loses about half of its capacity over three hours. A one-way slab strip heated only from below retains about 91% of its capacity at three hours, because only the bottom bar and a thin layer of concrete reach high temperature. The gap between the non-linear law and the fully plastic law stays below 6% for the steel column and for the T, rectan-gular and slab sections, and reaches 19% for the 300 × 600 beam, where the rising branch of the parabolic concrete law carries a larger share of the compression. Because the axial force is a single input, sweeping it over a range gives the full M-N interaction envelope at each fire time. This is the basis for judging whether the axial force that builds up in a restrained member under fire is favourable or unfavourable for its bending capacity. The tool is general and works for any cross-section modelled within the SAFIR. The post-pro-cessing code was developed with the help of an AI assistant, and testing how well such a tool can turn an engineering objective into working code was itself one of the aims of the work.
ING I - Scuola di Ingegneria Civile, Ambientale e Territoriale
21-lug-2026
2025/2026
L’incendio riduce la resistenza e la rigidezza dei materiali strutturali all’aumentare della tem-peratura. La verifica di una struttura in condizioni di incendio richiede di dimostrare che, per una assegnata durata di incendio, la struttura sia ancora in grado di sopportare i carichi ap-plicati. Software agli elementi finiti come SAFIR sono molto usati per modellare questo com-portamento, restituendo dati dettagliati per ogni fibra della sezione (temperatura, geometria, sforzo) ad ogni istante dell’analisi. I file di output grezzi, tuttavia, non possono essere usati direttamente per una verifica sezionale. Questa tesi sviluppa uno strumento di post-elaborazione orientato alla progettazione che colma questa lacuna. Lo strumento si compone di due parti. La prima legge i file SAFIR .OUT e .TEM e produce un file Excel strutturato con i dati per fibra alle durate di incendio standard degli Eurocodici. La seconda calcola la capacità M-N della sezione per ogni durata di incendio con un approccio basato sull’equilibrio: fissata l’azione assiale N, la curvatura κ viene incrementata da zero e, ad ogni passo, la deformazione di riferimento ε₀ viene trovata tramite il metodo di Newton-Raphson imponendo l’equilibrio. Il picco della curva M-κ fornisce il momento flet-tente massimo Mmax. Per ogni materiale sono implementate due leggi costitutive: quella non lineare completa degli Eurocodici e una versione perfettamente plastica. Il metodo è stato applicato a cinque sezioni. Per una colonna in acciaio con N = 2000 kN, il calcolo non converge intorno a 85 minuti, in accordo con il tempo di collasso riportato da SAFIR. Sono state poi studiate quattro sezioni in cemento armato con N = 500 kN. Una trave 300 × 600 mm esposta al fuoco su tre lati perde capacità flessionale da 488 a 163 kN·m nell’arco di 240 minuti. Una sezione a T mantiene un braccio di leva elevato, perché la soletta resta fredda, e la sua perdita in due ore è di circa il 38%. Una sezione rettangolare perde circa metà della sua capacità in tre ore. Una striscia di soletta riscaldata solo dal basso conserva circa il 91% della capacità a tre ore, perché solo la barra inferiore e un sottile strato di calcestruzzo raggiungono temperature elevate. Lo scarto tra la legge non lineare e quella completamente plastica resta sotto il 6% per la colonna in acciaio e per le sezioni a T, rettangolare e a soletta, e arriva al 19% per la trave 300 × 600, dove il ramo crescente della legge parabolica del cal-cestruzzo contribuisce maggiormente alla capacità a compressione. Poiché l’azione assiale è un singolo dato di ingresso, facendola variare su un intervallo si ot-tiene l’intero dominio di interazione M-N per ogni durata di incendio. Questa è la base per giudicare se l’incremento di forza assiale che si sviluppa in un elemento vincolato durante l’in-cendio sia favorevole o sfavorevole per la sua capacità flessionale. Lo strumento è generale e funziona per qualsiasi sezione che SAFIR sia in grado di trattare. Il codice di post-elaborazione è stato sviluppato con l'aiuto dell' intelligenza artificiale, e verificare quanto un simile stru-mento riesca a trasformare un obiettivo ingegneristico in codice funzionante è stato esso stesso uno degli scopi del presente lavoro di tesi.
File allegati
File Dimensione Formato  
2026_07_PANDIT.pdf

non accessibile

Dimensione 4.55 MB
Formato Adobe PDF
4.55 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/259438