This chapter presents a state-of-the-art review of electronic power converters used to supply high-power water electrolyzers (hundreds of kW to multi-MW scale) from the AC grid. Because electrolyzers behave as strongly nonlinear, largely resistive DC loads governed by Faraday's law, the converter topology directly determines hydrogen production efficiency, current ripple tolerance, and grid power quality. The review begins with the electrochemical fundamentals (reversible and thermoneutral voltages, ohmic and activation overpotentials) and the resulting electrical equivalent-circuit models used to represent alkaline and PEM stacks. It then surveys converter topologies in increasing order of sophistication: uncontrolled diode rectifiers (three-phase bridge, double-star, six-phase, twelve-pulse configurations), thyristor-based controlled rectifiers, forced-commutated IGBT converters (voltage source and current source converters), and two-stage architectures combining a rectifier front-end with interleaved buck DC-DC stages. A comparative simulation study on a 1 MVA / 0.9 MW PEM system shows that voltage source converters (VSCs) offer sub-millisecond dynamic response, near-unity power factor, and grid fault-ride-through capability — features unavailable to diode and thyristor rectifiers — at a higher capital cost (~600 USD/kW). Two case studies are examined in depth: (1) a 5 kW prototype using a small DC-link film capacitor with feed-forward ripple compensation, which is shown to work well on stiff grids but to dangerously excite an LC resonance and worsen grid-side THD on weak grids; and (2) an analytical model of a 6-pulse thyristor rectifier driving a constant-voltage electrolyzer load (validated on a 5.5 MW system), which demonstrates that the classical cosine voltage formula is invalid for this load type and that filter inductance sizing critically affects controllability, reactive power demand, and IEEE 519 harmonic compliance. Overall, the chapter establishes that converter choice for electrolyzer applications involves trade-offs among cost, reliability, controllability, harmonic performance, and grid-support capability, with VSC-based architectures emerging as the most capable — though not always most economical — solution for future large-scale, grid-code-compliant hydrogen production.

Questo capitolo presenta una rassegna dello stato dell'arte sui convertitori elettronici di potenza impiegati per alimentare elettrolizzatori ad alta potenza (da centinaia di kW fino alla scala multi-MW) a partire dalla rete AC. Poiché gli elettrolizzatori si comportano come carichi DC fortemente non lineari, governati dalla legge di Faraday, la topologia del convertitore determina direttamente l'efficienza di produzione dell'idrogeno, la tolleranza al ripple di corrente e la qualità della potenza lato rete. La rassegna parte dai fondamenti elettrochimici (tensione reversibile e termoneutra, sovratensioni ohmiche e di attivazione) e dai relativi modelli a circuito equivalente usati per rappresentare gli stack alcalini e PEM. Vengono poi analizzate le topologie di convertitore in ordine crescente di complessità: raddrizzatori a diodi non controllati (ponte trifase, doppia stella, esafase, configurazioni a dodici impulsi), raddrizzatori controllati a tiristori, convertitori IGBT a commutazione forzata (a sorgente di tensione e a sorgente di corrente), e architetture a due stadi che combinano un raddrizzatore frontale con stadi buck DC-DC interallacciati. Uno studio di simulazione comparativo su un sistema PEM da 1 MVA / 0,9 MW mostra che i convertitori a sorgente di tensione (VSC) offrono una risposta dinamica inferiore al millisecondo, fattore di potenza prossimo all'unità e capacità di "fault ride-through" in caso di guasti di rete — funzionalità assenti nei raddrizzatori a diodi e a tiristori — a fronte di un costo di capitale più elevato (~600 USD/kW). Vengono approfonditi due casi di studio: (1) un prototipo da 5 kW con condensatore di link DC in film di piccola capacità e compensazione feed-forward del ripple, efficace su reti rigide ma in grado di eccitare pericolosamente una risonanza LC e peggiorare la THD lato rete su reti deboli; e (2) un modello analitico di raddrizzatore a tiristori a 6 impulsi che alimenta un carico elettrolizzatore a tensione costante (validato su un sistema da 5,5 MW), che dimostra come la classica formula del coseno per la tensione non sia valida per questo tipo di carico e come il dimensionamento dell'induttanza di filtro influisca in modo critico su controllabilità, richiesta di potenza reattiva e conformità armonica alla norma IEEE 519. In sintesi, il capitolo evidenzia come la scelta del convertitore per applicazioni di elettrolisi comporti compromessi tra costo, affidabilità, controllabilità, prestazioni armoniche e capacità di supporto alla rete, con le architetture basate su VSC che emergono come soluzione più performante — anche se non sempre la più economica — per la produzione di idrogeno su larga scala conforme ai futuri codici di rete.

Electronic converters for high power electrolysers (hundreds of kilowatts or megawatts)

Zeng, Yangting
2025/2026

Abstract

This chapter presents a state-of-the-art review of electronic power converters used to supply high-power water electrolyzers (hundreds of kW to multi-MW scale) from the AC grid. Because electrolyzers behave as strongly nonlinear, largely resistive DC loads governed by Faraday's law, the converter topology directly determines hydrogen production efficiency, current ripple tolerance, and grid power quality. The review begins with the electrochemical fundamentals (reversible and thermoneutral voltages, ohmic and activation overpotentials) and the resulting electrical equivalent-circuit models used to represent alkaline and PEM stacks. It then surveys converter topologies in increasing order of sophistication: uncontrolled diode rectifiers (three-phase bridge, double-star, six-phase, twelve-pulse configurations), thyristor-based controlled rectifiers, forced-commutated IGBT converters (voltage source and current source converters), and two-stage architectures combining a rectifier front-end with interleaved buck DC-DC stages. A comparative simulation study on a 1 MVA / 0.9 MW PEM system shows that voltage source converters (VSCs) offer sub-millisecond dynamic response, near-unity power factor, and grid fault-ride-through capability — features unavailable to diode and thyristor rectifiers — at a higher capital cost (~600 USD/kW). Two case studies are examined in depth: (1) a 5 kW prototype using a small DC-link film capacitor with feed-forward ripple compensation, which is shown to work well on stiff grids but to dangerously excite an LC resonance and worsen grid-side THD on weak grids; and (2) an analytical model of a 6-pulse thyristor rectifier driving a constant-voltage electrolyzer load (validated on a 5.5 MW system), which demonstrates that the classical cosine voltage formula is invalid for this load type and that filter inductance sizing critically affects controllability, reactive power demand, and IEEE 519 harmonic compliance. Overall, the chapter establishes that converter choice for electrolyzer applications involves trade-offs among cost, reliability, controllability, harmonic performance, and grid-support capability, with VSC-based architectures emerging as the most capable — though not always most economical — solution for future large-scale, grid-code-compliant hydrogen production.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Questo capitolo presenta una rassegna dello stato dell'arte sui convertitori elettronici di potenza impiegati per alimentare elettrolizzatori ad alta potenza (da centinaia di kW fino alla scala multi-MW) a partire dalla rete AC. Poiché gli elettrolizzatori si comportano come carichi DC fortemente non lineari, governati dalla legge di Faraday, la topologia del convertitore determina direttamente l'efficienza di produzione dell'idrogeno, la tolleranza al ripple di corrente e la qualità della potenza lato rete. La rassegna parte dai fondamenti elettrochimici (tensione reversibile e termoneutra, sovratensioni ohmiche e di attivazione) e dai relativi modelli a circuito equivalente usati per rappresentare gli stack alcalini e PEM. Vengono poi analizzate le topologie di convertitore in ordine crescente di complessità: raddrizzatori a diodi non controllati (ponte trifase, doppia stella, esafase, configurazioni a dodici impulsi), raddrizzatori controllati a tiristori, convertitori IGBT a commutazione forzata (a sorgente di tensione e a sorgente di corrente), e architetture a due stadi che combinano un raddrizzatore frontale con stadi buck DC-DC interallacciati. Uno studio di simulazione comparativo su un sistema PEM da 1 MVA / 0,9 MW mostra che i convertitori a sorgente di tensione (VSC) offrono una risposta dinamica inferiore al millisecondo, fattore di potenza prossimo all'unità e capacità di "fault ride-through" in caso di guasti di rete — funzionalità assenti nei raddrizzatori a diodi e a tiristori — a fronte di un costo di capitale più elevato (~600 USD/kW). Vengono approfonditi due casi di studio: (1) un prototipo da 5 kW con condensatore di link DC in film di piccola capacità e compensazione feed-forward del ripple, efficace su reti rigide ma in grado di eccitare pericolosamente una risonanza LC e peggiorare la THD lato rete su reti deboli; e (2) un modello analitico di raddrizzatore a tiristori a 6 impulsi che alimenta un carico elettrolizzatore a tensione costante (validato su un sistema da 5,5 MW), che dimostra come la classica formula del coseno per la tensione non sia valida per questo tipo di carico e come il dimensionamento dell'induttanza di filtro influisca in modo critico su controllabilità, richiesta di potenza reattiva e conformità armonica alla norma IEEE 519. In sintesi, il capitolo evidenzia come la scelta del convertitore per applicazioni di elettrolisi comporti compromessi tra costo, affidabilità, controllabilità, prestazioni armoniche e capacità di supporto alla rete, con le architetture basate su VSC che emergono come soluzione più performante — anche se non sempre la più economica — per la produzione di idrogeno su larga scala conforme ai futuri codici di rete.
File allegati
File Dimensione Formato  
Electronic converters for high power electrolyzers.docx

accessibile in internet solo dagli utenti autorizzati

Dimensione 3.7 MB
Formato Microsoft Word XML
3.7 MB Microsoft Word XML   Visualizza/Apri
Electronic converters for high power electrolyzers.pdf

accessibile in internet solo dagli utenti autorizzati

Dimensione 2.42 MB
Formato Adobe PDF
2.42 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/259921