The European energy transition calls for a fast-track expansion of offshore renewables. Airborne Wind Energy (AWE) is a disruptive technology that replaces heavy turbine towers with tethered aircraft to harness more powerful winds at higher altitudes. But commercial viability is very dependent on aerodynamic architecture and offshore infrastructure costs. This thesis reports a techno-economic comparison of two AWE paradigms: a flexible soft-wing kite and a high-efficiency rigid-wing glider simulated in a Mediterranean offshore environment. To provide an accurate assessment of the localized wind resource, the study compares the global ERA5 model with the high-resolution regional CERRA dataset at 100m and 300m altitudes. A framework based on MATLAB is used to assess the aerodynamic and financial performance of both systems through Annual Energy Production (AEP), Capacity Factor (CF), Net Present Value (NPV), and Levelized Cost of Energy (LCoE). Resource analysis shows CERRA picks up much stronger coastal winds (9.13 m/s at 300m). In this context, the rigid-wing system showed higher aerodynamic efficiency, with a 53% CF and an AEP of 860.02 MWh/year. But the massive capital investment needed for aerospace quality manufacturing and offshore mooring means that small-scale (250 kW) rigid drones are not financially viable. On the other hand, the soft-wing system was tested for operational sensitivity to tether fatigue. By increasing its cut-out speed from a conservative 15.5 m/s to 25 m/s, the AEP increased a bit (from 209.68 to 234.33 MWh/year at 300m). Despite lower gross energy generation, the soft kite's fundamentally lower Initial Capital Cost makes it a very competitive and financially positive solution for sub-megawatt deployment today. Ultimately, this research concludes that although rigid-wing AWE systems provide the highest theoretical yields, they must be scaled to the multi-megawatt class to amortize heavy marine costs. Soft-wing systems are the most economic and pragmatic path to small-scale offshore integration in the near term.

La transizione energetica europea richiede una rapida espansione delle fonti rinnovabili offshore. L'eolico d'alta quota (Airborne Wind Energy, AWE) offre una soluzione dirompente, sostituendo le pesanti torri delle turbine con velivoli vincolati per sfruttare i venti più forti ad alta quota. Tuttavia, la redditività commerciale dipende fortemente dall'architettura aerodinamica e dai costi delle infrastrutture offshore. Questa tesi presenta un'analisi comparativa tecnico-economica di due paradigmi AWE — un aquilone flessibile e un aliante ad alta efficienza ad ala rigida — simulati in un ambiente offshore mediterraneo. Per valutare accuratamente la risorsa eolica localizzata, lo studio confronta il modello globale ERA5 con il database regionale ad alta risoluzione CERRA alle altitudini di 100 m e 300 m. Un framework basato su MATLAB valuta le prestazioni aerodinamiche e finanziarie di entrambi i sistemi tramite la Produzione Energetica Annuale (AEP), il Fattore di Capacità (CF), il Valore Attuale Netto (NPV) e il Costo Attualizzato dell'Energia (LCoE). L'analisi della risorsa conferma che il database CERRA identifica venti costieri significativamente più forti, raggiungendo i 9,13 m/s a 300 m. In queste condizioni, il sistema ad ala rigida ha dimostrato un'efficienza aerodinamica superiore, ottenendo un CF del 53% e un AEP di 860.02 MWh/anno. Tuttavia, l'immensa spesa in conto capitale (CAPEX) richiesta per la produzione di grado aerospaziale e per gli ormeggi marini rende i droni rigidi su piccola scala (250 kW) finanziariamente insostenibili. Al contrario, il sistema ad ala flessibile è stato sottoposto a un'analisi di sensibilità per valutare l'impatto della fatica del cavo (tether). L'estensione della sua velocità di cut-out da un valore conservativo di 15,5 m/s a 25 m/s ha aumentato l'AEP un po (da 209.68 a 234.33 MWh/anno a 300 m). Nonostante una minore generazione di energia lorda, il Costo di Capitale Iniziale (ICC) nettamente inferiore dell'aquilone flessibile lo rende oggi una soluzione altamente competitiva e finanziariamente positiva per le installazioni offshore sub-megawatt. In definitiva, questa ricerca conclude che, sebbene i sistemi AWE ad ala rigida offrano i massimi rendimenti teorici, essi devono essere scalati alla classe multi-megawatt per ammortizzare i pesanti costi delle infrastrutture marine. Per l'integrazione offshore a breve termine e su piccola scala, i sistemi ad ala flessibile rappresentano attualmente il percorso economicamente più pragmatico.

Techno economic assessment of rigid and soft wing Airborne Wind Energy systems for offshore deployment in the Mediterranean

MOSLEMZADE, QAZAL
2025/2026

Abstract

The European energy transition calls for a fast-track expansion of offshore renewables. Airborne Wind Energy (AWE) is a disruptive technology that replaces heavy turbine towers with tethered aircraft to harness more powerful winds at higher altitudes. But commercial viability is very dependent on aerodynamic architecture and offshore infrastructure costs. This thesis reports a techno-economic comparison of two AWE paradigms: a flexible soft-wing kite and a high-efficiency rigid-wing glider simulated in a Mediterranean offshore environment. To provide an accurate assessment of the localized wind resource, the study compares the global ERA5 model with the high-resolution regional CERRA dataset at 100m and 300m altitudes. A framework based on MATLAB is used to assess the aerodynamic and financial performance of both systems through Annual Energy Production (AEP), Capacity Factor (CF), Net Present Value (NPV), and Levelized Cost of Energy (LCoE). Resource analysis shows CERRA picks up much stronger coastal winds (9.13 m/s at 300m). In this context, the rigid-wing system showed higher aerodynamic efficiency, with a 53% CF and an AEP of 860.02 MWh/year. But the massive capital investment needed for aerospace quality manufacturing and offshore mooring means that small-scale (250 kW) rigid drones are not financially viable. On the other hand, the soft-wing system was tested for operational sensitivity to tether fatigue. By increasing its cut-out speed from a conservative 15.5 m/s to 25 m/s, the AEP increased a bit (from 209.68 to 234.33 MWh/year at 300m). Despite lower gross energy generation, the soft kite's fundamentally lower Initial Capital Cost makes it a very competitive and financially positive solution for sub-megawatt deployment today. Ultimately, this research concludes that although rigid-wing AWE systems provide the highest theoretical yields, they must be scaled to the multi-megawatt class to amortize heavy marine costs. Soft-wing systems are the most economic and pragmatic path to small-scale offshore integration in the near term.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
La transizione energetica europea richiede una rapida espansione delle fonti rinnovabili offshore. L'eolico d'alta quota (Airborne Wind Energy, AWE) offre una soluzione dirompente, sostituendo le pesanti torri delle turbine con velivoli vincolati per sfruttare i venti più forti ad alta quota. Tuttavia, la redditività commerciale dipende fortemente dall'architettura aerodinamica e dai costi delle infrastrutture offshore. Questa tesi presenta un'analisi comparativa tecnico-economica di due paradigmi AWE — un aquilone flessibile e un aliante ad alta efficienza ad ala rigida — simulati in un ambiente offshore mediterraneo. Per valutare accuratamente la risorsa eolica localizzata, lo studio confronta il modello globale ERA5 con il database regionale ad alta risoluzione CERRA alle altitudini di 100 m e 300 m. Un framework basato su MATLAB valuta le prestazioni aerodinamiche e finanziarie di entrambi i sistemi tramite la Produzione Energetica Annuale (AEP), il Fattore di Capacità (CF), il Valore Attuale Netto (NPV) e il Costo Attualizzato dell'Energia (LCoE). L'analisi della risorsa conferma che il database CERRA identifica venti costieri significativamente più forti, raggiungendo i 9,13 m/s a 300 m. In queste condizioni, il sistema ad ala rigida ha dimostrato un'efficienza aerodinamica superiore, ottenendo un CF del 53% e un AEP di 860.02 MWh/anno. Tuttavia, l'immensa spesa in conto capitale (CAPEX) richiesta per la produzione di grado aerospaziale e per gli ormeggi marini rende i droni rigidi su piccola scala (250 kW) finanziariamente insostenibili. Al contrario, il sistema ad ala flessibile è stato sottoposto a un'analisi di sensibilità per valutare l'impatto della fatica del cavo (tether). L'estensione della sua velocità di cut-out da un valore conservativo di 15,5 m/s a 25 m/s ha aumentato l'AEP un po (da 209.68 a 234.33 MWh/anno a 300 m). Nonostante una minore generazione di energia lorda, il Costo di Capitale Iniziale (ICC) nettamente inferiore dell'aquilone flessibile lo rende oggi una soluzione altamente competitiva e finanziariamente positiva per le installazioni offshore sub-megawatt. In definitiva, questa ricerca conclude che, sebbene i sistemi AWE ad ala rigida offrano i massimi rendimenti teorici, essi devono essere scalati alla classe multi-megawatt per ammortizzare i pesanti costi delle infrastrutture marine. Per l'integrazione offshore a breve termine e su piccola scala, i sistemi ad ala flessibile rappresentano attualmente il percorso economicamente più pragmatico.
File allegati
File Dimensione Formato  
2026_07_Moslemzade_Executive Summary.pdf

accessibile in internet per tutti

Dimensione 2.3 MB
Formato Adobe PDF
2.3 MB Adobe PDF Visualizza/Apri
2026_07_Moslemzade_Tesi.pdf

accessibile in internet per tutti

Descrizione: This thesis presents a high-resolution Techno-Economic Analysis (TEA) of Airborne Wind Energy (AWE) systems within the Italian offshore environment. By transitioning from coarse-resolution atmospheric reanalysis to the 5.5 km CERRA dataset, this research identifies optimal high-yield 'hotspots' for AWE deployment. The study performs a comparative evaluation of rigid-wing (Ampyx AP3) and flexible soft-wing (SkySails PN-14) paradigms, quantifying the trade-off between aerodynamic power conversion and offshore infrastructure expenditure. The results demonstrate that while rigid-wing systems offer superior gross energy yields, the current marine Balance of System (BoS) requirements impose an infrastructure penalty that limits their sub-megawatt commercial viability, establishing flexible soft-wing architectures as the most economically pragmatic solution for near-term Italian offshore integration.
Dimensione 5.27 MB
Formato Adobe PDF
5.27 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/260317