This thesis presents the development, implementation, and preliminary evaluation of a bilateral inertial measurement system designed for deployment on ice hockey skates. The central motivation is to overcome a fundamental limitation of existing commer- cial athlete-monitoring solutions, which employ a single torso-mounted sensor and are therefore incapable of resolving the side-specific biomechanical parameters required for skating-technique assessment and lower-limb asymmetry analysis. The measurement platform is built around two self-contained M5Stack Core2 units, each integrating a six-axis MPU6886 inertial measurement unit, onboard battery, local SD- card storage, and wireless communication. A dedicated 3D-printed enclosure and Voile- strap mounting system attach each unit rigidly to the dorsal surface of a skate boot. Signals were acquired using a software-timed loop targeting approximately 300 Hz (median achieved rate ≈333 Hz, with non-uniform timestamps resampled to a uniform 150 Hz grid in post-processing); full-scale ranges are ±16 g and ±2000 deg/s respectively, and bilateral synchronisation is achieved via an ESP-NOW remote controller. The physical measurement principles underlying the system are discussed in detail: the accelerometer reports specific force rather than kinematic acceleration, necessitating gravity removal in post-processing, while the lateral gyroscope channel captures the alternating suppression and release of angular velocity between the constrained stance and free-swing phases of the skating stride. A Python-based bilateral analysis pipeline was developed to manage data ingestion, tem- poral alignment, gravity removal, signal filtering, and gait event detection; all outputs were generated automatically for each trial. Three gait event detection algorithms were implemented and cross-validated. The T1 and T12 methods are adapted from the frame- work of Khandan et al., identifying events from vertical acceleration peaks and lateral gyroscope peaks respectively. T1 performs well during mid- and late-sprint skating, while T12 improves robustness during the standing-start acceleration phase. To further ad- dress the failure modes of both methods — particularly amplitude variability across the standing-start phase — a third method, T-GTM (Gyroscope Template Matching), was developed as part of this work. T-GTM extends the gyroscope-based approach with ii | Abstract an autocorrelation-based stride period estimation and a trial-specific template-matching step, yielding more consistent event timing across all sprint phases. Following parameter tuning across a representative trial subset, T-GTM was designated the primary detection method for all stride-level metrics. The instrumented system was deployed in a structured data-collection session at the Cornèr Arena in Lugano, involving six elite male U21 ice hockey players performing a 30 m sprint protocol and a 500 m endurance circuit. Stride-level parameters includ- ing contact time, swing time, cadence, and bilateral symmetry index were extracted for both protocols. Results revealed descriptive cross-player differences in stride strategy and asymmetry patterns, consistent with dryland force-platform metrics collected in the same session. Circuit-phase segmentation of the 500 m trial provided additional insight into the evolution of mechanical output across straight sections and turns. Per-phase decom- position of bilateral asymmetry further distinguished geometry-driven loading differences between turn directions from structural athlete-specific imbalances, enabling identification of one participant’s injury-related offloading pattern across all circuit phases. The system demonstrates technical feasibility under realistic on-ice conditions and establishes a foun- dation for longitudinal skating-biomechanics research and clinical asymmetry monitoring in ice hockey.

La presente tesi descrive lo sviluppo, l’implementazione e la valutazione preliminare di un sistema di misura inerziale bilaterale progettato per l’impiego su pattini da hockey su ghiaccio. La motivazione centrale è superare una limitazione fondamentale dei sistemi commerciali di monitoraggio degli atleti, che impiegano un singolo sensore montato sul tronco e sono pertanto incapaci di risolvere i parametri biomeccanici specifici per lato necessari per la valutazione della tecnica di pattinaggio e l’analisi dell’asimmetria degli arti inferiori. La piattaforma di misura è basata su due unità M5Stack Core2 autonome, ciascuna inte- grata con un’unità di misura inerziale MPU6886 a sei assi, batteria incorporata, memoria locale su scheda SD e comunicazione wireless. Un apposito alloggiamento stampato in 3D e un sistema di fissaggio con cinghie Voile consentono di montare ciascuna unità rigida- mente sulla superficie dorsale dello scarpone del pattino. I segnali sono acquisiti tramite un loop software con frequenza target di circa 300 Hz (frequenza mediana raggiunta ≈333 Hz, con timestamp non uniformi ricampionati a una griglia uniforme di 150 Hz in post-elaborazione); gli intervalli di scala sono ±16 g e ±2000 deg/s rispettivamente, e la sincronizzazione bilaterale è ottenuta tramite un controller remoto ESP-NOW. I principi fisici di misura alla base del sistema sono discussi in dettaglio: l’accelerometro rileva la forza specifica piuttosto che l’accelerazione cinematica, rendendo necessaria la rimozione della componente gravitazionale in post-elaborazione, mentre il canale del giroscopio lat- erale cattura l’alternanza di soppressione e rilascio della velocità angolare tra le fasi di appoggio vincolato e oscillazione libera dell’andatura sul ghiaccio. È stata sviluppata una pipeline di analisi bilaterale in Python per gestire l’acquisizione dei dati, l’allineamento temporale, la rimozione della gravità, il filtraggio del segnale e il rilevamento degli eventi dell’andatura, con tutti gli output generati automaticamente per ciascuna prova. Tre algoritmi di rilevamento degli eventi dell’andatura sono stati implementati e sottoposti a validazione incrociata. I metodi T1 e T12 sono adattati dal framework di Khandan et al., identificando gli eventi rispettivamente dai picchi di accelerazione verticale e dai picchi del giroscopio laterale. T1 fornisce buone prestazioni nella fase centrale e finale dello sprint, mentre T12 migliora la robustezza durante la fase di accelerazione da fermo. Per superare ulteriormente le limitazioni di entrambi i metodi — in particolare la variabilità di ampiezza nella fase di accelerazione da fermo — è stato sviluppato nell’ambito di questo lavoro un terzo metodo, T-GTM (Gyroscope Template Matching). T-GTM estende l’approccio basato sul giroscopio con una stima del periodo di passo basata sull’autocorrelazione e una fase di template matching specifica per ciascuna prova, ottenendo una temporizzazione degli eventi più coerente in tutte le fasi dello sprint. A seguito della taratura dei parametri su un sottoinsieme rappresentativo di prove, T-GTM è stato designato come metodo di rilevamento primario per tutte le metriche a livello di passo. Il sistema strumentato è stato impiegato in una sessione di raccolta dati strutturata alla Cornèr Arena di Lugano, coinvolgendo sei giocatori maschi d’élite Under-21 di hockey su ghiaccio che eseguivano un protocollo di sprint da 30 m e un circuito di resistenza da 500 m. I parametri dell’andatura a livello di passo — tra cui tempo di contatto, tempo di oscillazione, cadenza e indice di simmetria bilaterale — sono stati estratti per entrambi i protocolli. I risultati hanno evidenziato differenze significative tra i giocatori nelle strate- gie di passo e nei pattern di asimmetria, coerenti con le metriche rilevate su piattaforma di forza fuori dal ghiaccio nella stessa sessione. La segmentazione per fase del circuito nella prova da 500 m ha fornito ulteriori informazioni sull’evoluzione del carico inerziale nei rettilinei e nelle curve. La scomposizione per fase dell’asimmetria bilaterale ha inoltre permesso di distinguere le differenze di carico indotte dalla geometria del circuito tra le curve nei due sensi di percorrenza dagli squilibri strutturali specifici dell’atleta, consen- tendo l’identificazione del pattern di scarico legato all’infortunio di un partecipante su tutte le fasi del circuito. Il sistema dimostra la fattibilità tecnica in condizioni realis- tiche di pattinaggio e stabilisce le basi per la ricerca longitudinale sulla biomeccanica del pattinaggio e il monitoraggio clinico dell’asimmetria nell’hockey su ghiaccio

Development of a bilateral IMU system for ice hockey skating analysis

van HAM, IAN
2025/2026

Abstract

This thesis presents the development, implementation, and preliminary evaluation of a bilateral inertial measurement system designed for deployment on ice hockey skates. The central motivation is to overcome a fundamental limitation of existing commer- cial athlete-monitoring solutions, which employ a single torso-mounted sensor and are therefore incapable of resolving the side-specific biomechanical parameters required for skating-technique assessment and lower-limb asymmetry analysis. The measurement platform is built around two self-contained M5Stack Core2 units, each integrating a six-axis MPU6886 inertial measurement unit, onboard battery, local SD- card storage, and wireless communication. A dedicated 3D-printed enclosure and Voile- strap mounting system attach each unit rigidly to the dorsal surface of a skate boot. Signals were acquired using a software-timed loop targeting approximately 300 Hz (median achieved rate ≈333 Hz, with non-uniform timestamps resampled to a uniform 150 Hz grid in post-processing); full-scale ranges are ±16 g and ±2000 deg/s respectively, and bilateral synchronisation is achieved via an ESP-NOW remote controller. The physical measurement principles underlying the system are discussed in detail: the accelerometer reports specific force rather than kinematic acceleration, necessitating gravity removal in post-processing, while the lateral gyroscope channel captures the alternating suppression and release of angular velocity between the constrained stance and free-swing phases of the skating stride. A Python-based bilateral analysis pipeline was developed to manage data ingestion, tem- poral alignment, gravity removal, signal filtering, and gait event detection; all outputs were generated automatically for each trial. Three gait event detection algorithms were implemented and cross-validated. The T1 and T12 methods are adapted from the frame- work of Khandan et al., identifying events from vertical acceleration peaks and lateral gyroscope peaks respectively. T1 performs well during mid- and late-sprint skating, while T12 improves robustness during the standing-start acceleration phase. To further ad- dress the failure modes of both methods — particularly amplitude variability across the standing-start phase — a third method, T-GTM (Gyroscope Template Matching), was developed as part of this work. T-GTM extends the gyroscope-based approach with ii | Abstract an autocorrelation-based stride period estimation and a trial-specific template-matching step, yielding more consistent event timing across all sprint phases. Following parameter tuning across a representative trial subset, T-GTM was designated the primary detection method for all stride-level metrics. The instrumented system was deployed in a structured data-collection session at the Cornèr Arena in Lugano, involving six elite male U21 ice hockey players performing a 30 m sprint protocol and a 500 m endurance circuit. Stride-level parameters includ- ing contact time, swing time, cadence, and bilateral symmetry index were extracted for both protocols. Results revealed descriptive cross-player differences in stride strategy and asymmetry patterns, consistent with dryland force-platform metrics collected in the same session. Circuit-phase segmentation of the 500 m trial provided additional insight into the evolution of mechanical output across straight sections and turns. Per-phase decom- position of bilateral asymmetry further distinguished geometry-driven loading differences between turn directions from structural athlete-specific imbalances, enabling identification of one participant’s injury-related offloading pattern across all circuit phases. The system demonstrates technical feasibility under realistic on-ice conditions and establishes a foun- dation for longitudinal skating-biomechanics research and clinical asymmetry monitoring in ice hockey.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-lug-2026
2025/2026
La presente tesi descrive lo sviluppo, l’implementazione e la valutazione preliminare di un sistema di misura inerziale bilaterale progettato per l’impiego su pattini da hockey su ghiaccio. La motivazione centrale è superare una limitazione fondamentale dei sistemi commerciali di monitoraggio degli atleti, che impiegano un singolo sensore montato sul tronco e sono pertanto incapaci di risolvere i parametri biomeccanici specifici per lato necessari per la valutazione della tecnica di pattinaggio e l’analisi dell’asimmetria degli arti inferiori. La piattaforma di misura è basata su due unità M5Stack Core2 autonome, ciascuna inte- grata con un’unità di misura inerziale MPU6886 a sei assi, batteria incorporata, memoria locale su scheda SD e comunicazione wireless. Un apposito alloggiamento stampato in 3D e un sistema di fissaggio con cinghie Voile consentono di montare ciascuna unità rigida- mente sulla superficie dorsale dello scarpone del pattino. I segnali sono acquisiti tramite un loop software con frequenza target di circa 300 Hz (frequenza mediana raggiunta ≈333 Hz, con timestamp non uniformi ricampionati a una griglia uniforme di 150 Hz in post-elaborazione); gli intervalli di scala sono ±16 g e ±2000 deg/s rispettivamente, e la sincronizzazione bilaterale è ottenuta tramite un controller remoto ESP-NOW. I principi fisici di misura alla base del sistema sono discussi in dettaglio: l’accelerometro rileva la forza specifica piuttosto che l’accelerazione cinematica, rendendo necessaria la rimozione della componente gravitazionale in post-elaborazione, mentre il canale del giroscopio lat- erale cattura l’alternanza di soppressione e rilascio della velocità angolare tra le fasi di appoggio vincolato e oscillazione libera dell’andatura sul ghiaccio. È stata sviluppata una pipeline di analisi bilaterale in Python per gestire l’acquisizione dei dati, l’allineamento temporale, la rimozione della gravità, il filtraggio del segnale e il rilevamento degli eventi dell’andatura, con tutti gli output generati automaticamente per ciascuna prova. Tre algoritmi di rilevamento degli eventi dell’andatura sono stati implementati e sottoposti a validazione incrociata. I metodi T1 e T12 sono adattati dal framework di Khandan et al., identificando gli eventi rispettivamente dai picchi di accelerazione verticale e dai picchi del giroscopio laterale. T1 fornisce buone prestazioni nella fase centrale e finale dello sprint, mentre T12 migliora la robustezza durante la fase di accelerazione da fermo. Per superare ulteriormente le limitazioni di entrambi i metodi — in particolare la variabilità di ampiezza nella fase di accelerazione da fermo — è stato sviluppato nell’ambito di questo lavoro un terzo metodo, T-GTM (Gyroscope Template Matching). T-GTM estende l’approccio basato sul giroscopio con una stima del periodo di passo basata sull’autocorrelazione e una fase di template matching specifica per ciascuna prova, ottenendo una temporizzazione degli eventi più coerente in tutte le fasi dello sprint. A seguito della taratura dei parametri su un sottoinsieme rappresentativo di prove, T-GTM è stato designato come metodo di rilevamento primario per tutte le metriche a livello di passo. Il sistema strumentato è stato impiegato in una sessione di raccolta dati strutturata alla Cornèr Arena di Lugano, coinvolgendo sei giocatori maschi d’élite Under-21 di hockey su ghiaccio che eseguivano un protocollo di sprint da 30 m e un circuito di resistenza da 500 m. I parametri dell’andatura a livello di passo — tra cui tempo di contatto, tempo di oscillazione, cadenza e indice di simmetria bilaterale — sono stati estratti per entrambi i protocolli. I risultati hanno evidenziato differenze significative tra i giocatori nelle strate- gie di passo e nei pattern di asimmetria, coerenti con le metriche rilevate su piattaforma di forza fuori dal ghiaccio nella stessa sessione. La segmentazione per fase del circuito nella prova da 500 m ha fornito ulteriori informazioni sull’evoluzione del carico inerziale nei rettilinei e nelle curve. La scomposizione per fase dell’asimmetria bilaterale ha inoltre permesso di distinguere le differenze di carico indotte dalla geometria del circuito tra le curve nei due sensi di percorrenza dagli squilibri strutturali specifici dell’atleta, consen- tendo l’identificazione del pattern di scarico legato all’infortunio di un partecipante su tutte le fasi del circuito. Il sistema dimostra la fattibilità tecnica in condizioni realis- tiche di pattinaggio e stabilisce le basi per la ricerca longitudinale sulla biomeccanica del pattinaggio e il monitoraggio clinico dell’asimmetria nell’hockey su ghiaccio
File allegati
File Dimensione Formato  
Development_of_a_Bilateral_IMU_System_for_Ice_Hockey_Skating_Analysis.pdf

accessibile in internet per tutti

Dimensione 5.78 MB
Formato Adobe PDF
5.78 MB Adobe PDF Visualizza/Apri
Executive_Summary_vanHam_10947939.pdf

accessibile in internet per tutti

Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/260476