Rogowski coils are widely used for current measurement owing to their non-intrusive installation, wide bandwidth, linear response, and low cost. This thesis investigates the variability of measurement performance among nominally identical Rogowski coils belonging to the same production batch under off-nominal operating conditions. Three winding configurations—single-, double-, and three-layer coils—were experimentally characterized in terms of sensitivity to busbar displacement and susceptibility to external magnetic fields. The results reveal a significant variability among nominally identical specimens, with the observed dispersion becoming more pronounced as the winding structure grows in complexity. These findings indicate that nominal design parameters alone are insufficient to accurately predict measurement performance and underline the importance of accounting for manufacturing-induced variability in uncertainty assessment. In addition, the influence of temperature on the coil electrical parameters and resonance frequency was experimentally characterized. Finally, the linear dependence of coil resistance on temperature also highlights the potential of the Rogowski coil to operate as a self-sensing element for temperature estimation.
Le bobine di Rogowski sono ampiamente impiegate per la misura di corrente grazie alla loro installazione non invasiva, all'ampia banda passante, alla risposta lineare e al costo contenuto. Questa tesi analizza la variabilità delle prestazioni di misura di bobine appartenenti allo stesso lotto produttivo in condizioni operative non nominali. In particolare, sono state caratterizzate sperimentalmente tre configurazioni di avvolgimento — a singolo, doppio e triplo strato — valutandone la sensibilità allo spostamento del conduttore primario e la suscettibilità ai campi magnetici esterni. I risultati mostrano come esemplari nominalmente identici possano presentare differenze apprezzabili nelle prestazioni di misura. Tale dispersione tende inoltre a crescere con la complessità della struttura di avvolgimento. Questi risultati indicano che i parametri elettrici nominali non sono sufficienti a prevedere accuratamente il comportamento della bobina e sottolineano l'importanza di considerare la variabilità introdotta dal processo produttivo nella valutazione dell'incertezza di misura. È stata inoltre studiata sperimentalmente l'influenza della temperatura sui parametri elettrici della bobina e sulla sua frequenza di risonanza. Infine, la dipendenza lineare della resistenza elettrica dalla temperatura suggerisce la possibilità di utilizzare la bobina di Rogowski anche come sensore di temperatura.
Experimental characterization of Rogowski coil performance under off-nominal conditions: comparative evaluation of intra-batch variabillity toward high-accuracy measurements
Ferretti, Luca
2025/2026
Abstract
Rogowski coils are widely used for current measurement owing to their non-intrusive installation, wide bandwidth, linear response, and low cost. This thesis investigates the variability of measurement performance among nominally identical Rogowski coils belonging to the same production batch under off-nominal operating conditions. Three winding configurations—single-, double-, and three-layer coils—were experimentally characterized in terms of sensitivity to busbar displacement and susceptibility to external magnetic fields. The results reveal a significant variability among nominally identical specimens, with the observed dispersion becoming more pronounced as the winding structure grows in complexity. These findings indicate that nominal design parameters alone are insufficient to accurately predict measurement performance and underline the importance of accounting for manufacturing-induced variability in uncertainty assessment. In addition, the influence of temperature on the coil electrical parameters and resonance frequency was experimentally characterized. Finally, the linear dependence of coil resistance on temperature also highlights the potential of the Rogowski coil to operate as a self-sensing element for temperature estimation.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_07_Ferretti_Tesi.pdf
non accessibile
Descrizione: Testo della tesi
Dimensione
23.64 MB
Formato
Adobe PDF
|
23.64 MB | Adobe PDF | Visualizza/Apri |
|
2026_07_Ferretti_ExecutiveSummary.pdf
non accessibile
Descrizione: Executive Summary
Dimensione
1.44 MB
Formato
Adobe PDF
|
1.44 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/260491