The objective of this thesis is to develop, in collaboration with the Pineta Grande Hospital in Caserta, a patient-specific finite element model of the glenohumeral joint, based on anatomical data obtained from MRI images. The model was created to study shoulder stability during a critical movement, with particular attention to the role played by the morphology of the glenoid and passive stabilizers. Starting from geometries reconstructed through the segmentation of clinical images from a previous thesis, a numerical model in Abaqus was revised and refined. The corrective measures involved redefining the local reference systems, contact interfaces, interpenetrations, and mass scaling parameters. Once the physiological reference configuration was validated, various anatomical and material variants were generated to evaluate the effect of three different pathological factors on glenohumeral stability: anteroinferior glenoid bone loss, alteration of glenoid concavity, and the introduction of glenohumeral ligament laxity. The comparative analysis highlights bone loss as the most destabilizing factor. This defect results in a marked loss of stability at low degrees of abduction and an eccentric transfer of contact pressures, which are no longer effectively compensated for by the action of the glenohumeral ligaments. The model with hyperlaxity confirms the importance of the inferior glenohumeral ligament as the primary stabilizer, allowing for greater joint mobility and precipitating the phenomenon of dislocation. The alteration of concavity alone, while modifying the pressure pattern at the joint interface, does not produce macroscopic kinematic changes. Overall, the model has made it possible to correlate specific structural defects with the biomechanical mechanisms of instability, confirming the eccentricity of glenohumeral contact as a primary clinical risk indicator and laying the methodological groundwork for future extensions, including the integration of active stabilizers.

Il presente lavoro di tesi ha l'obiettivo di sviluppare, in accordo con l'ospedale Pineta Grande di Caserta, un modello agli elementi finiti paziente specifico dell'articolazione gleno-omerale, partendo da dati anatomici ottenuti da immagini MRI. Il modello è stato realizzato per studiare la stabilità della spalla durante un movimento critico, con particolare attenzione al ruolo che ricoprono morfologia della glena e stabilizzatori passivi. Partendo da geometrie ricostruite tramite segmentazione di immagini cliniche da un precedente lavoro di tesi, è stato revisionato e perfezionato un modello numerico in Abaqus. Gli interventi correttivi hanno riguardato la ridefinizione dei sistemi di riferimento locali, delle interfacce di contatto, delle compenetrazioni e dei parametri di mass scaling. Validata la configurazione fisiologica di riferimento, sono state generate differenti varianti anatomiche e costitutive per valutare l'effetto che hanno sulla stabilità gleno-omerale tre differenti fattori patologici: la perdita ossea glenoidea antero-inferiore, l'alterazione della concavità glenoidea e l'introduzione di una iperlassità dei legamenti gleno-omerali. L'analisi comparativa prodotta evidenzia la perdita ossea come la condizione più destabilizzante. Tale difetto comporta una marcata perdita di contenimento a bassi gradi di abduzione e un trasferimento eccentrico delle pressioni di contatto, non più efficacemente compensate dall'azione dei legamenti gleno-omerali. Il modello con iperlassità conferma l'importanza del legamento gleno-omerale inferiore come stabilizzatore primario, concedendo maggiore libertà articolare e anticipando il fenomeno di lussazione. La sola alterazione della concavità, pur modificando il pattern delle pressioni dell'interfaccia articolare, non produce variazioni cinematiche macroscopiche. Nel complesso, il modello ha permesso di correlare specifici difetti strutturali ai meccanismi biomeccanici dell'instabilità, confermando l'eccentricità del contatto gleno-omerale come primario indicatore clinico di rischio e ponendo basi metodologiche per futuri ampliamenti, tra cui l'integrazione degli stabilizzatori attivi.

Sviluppo di un modello biomeccanico agli elementi finiti della spalla: analisi del ruolo di geometria glenoidea e legamenti nella stabilità articolare

LONGHI, RICCARDO
2025/2026

Abstract

The objective of this thesis is to develop, in collaboration with the Pineta Grande Hospital in Caserta, a patient-specific finite element model of the glenohumeral joint, based on anatomical data obtained from MRI images. The model was created to study shoulder stability during a critical movement, with particular attention to the role played by the morphology of the glenoid and passive stabilizers. Starting from geometries reconstructed through the segmentation of clinical images from a previous thesis, a numerical model in Abaqus was revised and refined. The corrective measures involved redefining the local reference systems, contact interfaces, interpenetrations, and mass scaling parameters. Once the physiological reference configuration was validated, various anatomical and material variants were generated to evaluate the effect of three different pathological factors on glenohumeral stability: anteroinferior glenoid bone loss, alteration of glenoid concavity, and the introduction of glenohumeral ligament laxity. The comparative analysis highlights bone loss as the most destabilizing factor. This defect results in a marked loss of stability at low degrees of abduction and an eccentric transfer of contact pressures, which are no longer effectively compensated for by the action of the glenohumeral ligaments. The model with hyperlaxity confirms the importance of the inferior glenohumeral ligament as the primary stabilizer, allowing for greater joint mobility and precipitating the phenomenon of dislocation. The alteration of concavity alone, while modifying the pressure pattern at the joint interface, does not produce macroscopic kinematic changes. Overall, the model has made it possible to correlate specific structural defects with the biomechanical mechanisms of instability, confirming the eccentricity of glenohumeral contact as a primary clinical risk indicator and laying the methodological groundwork for future extensions, including the integration of active stabilizers.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Il presente lavoro di tesi ha l'obiettivo di sviluppare, in accordo con l'ospedale Pineta Grande di Caserta, un modello agli elementi finiti paziente specifico dell'articolazione gleno-omerale, partendo da dati anatomici ottenuti da immagini MRI. Il modello è stato realizzato per studiare la stabilità della spalla durante un movimento critico, con particolare attenzione al ruolo che ricoprono morfologia della glena e stabilizzatori passivi. Partendo da geometrie ricostruite tramite segmentazione di immagini cliniche da un precedente lavoro di tesi, è stato revisionato e perfezionato un modello numerico in Abaqus. Gli interventi correttivi hanno riguardato la ridefinizione dei sistemi di riferimento locali, delle interfacce di contatto, delle compenetrazioni e dei parametri di mass scaling. Validata la configurazione fisiologica di riferimento, sono state generate differenti varianti anatomiche e costitutive per valutare l'effetto che hanno sulla stabilità gleno-omerale tre differenti fattori patologici: la perdita ossea glenoidea antero-inferiore, l'alterazione della concavità glenoidea e l'introduzione di una iperlassità dei legamenti gleno-omerali. L'analisi comparativa prodotta evidenzia la perdita ossea come la condizione più destabilizzante. Tale difetto comporta una marcata perdita di contenimento a bassi gradi di abduzione e un trasferimento eccentrico delle pressioni di contatto, non più efficacemente compensate dall'azione dei legamenti gleno-omerali. Il modello con iperlassità conferma l'importanza del legamento gleno-omerale inferiore come stabilizzatore primario, concedendo maggiore libertà articolare e anticipando il fenomeno di lussazione. La sola alterazione della concavità, pur modificando il pattern delle pressioni dell'interfaccia articolare, non produce variazioni cinematiche macroscopiche. Nel complesso, il modello ha permesso di correlare specifici difetti strutturali ai meccanismi biomeccanici dell'instabilità, confermando l'eccentricità del contatto gleno-omerale come primario indicatore clinico di rischio e ponendo basi metodologiche per futuri ampliamenti, tra cui l'integrazione degli stabilizzatori attivi.
File allegati
File Dimensione Formato  
2026_06_Longhi_Tesi.pdf

accessibile in internet solo dagli utenti autorizzati

Dimensione 35.83 MB
Formato Adobe PDF
35.83 MB Adobe PDF   Visualizza/Apri
2026_06_Longhi_ExecutiveSummary.pdf

accessibile in internet solo dagli utenti autorizzati

Dimensione 6.61 MB
Formato Adobe PDF
6.61 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/260840