High-temperature heat pumps (HTHPs) are promising solutions for reducing fossil-fuel consumption in industrial heat supply. However, the integration of HTHPs in automotive paint shops has mainly been studied under steady-state conditions, while real plants operate under variable production rates and significant thermal inertia. Therefore, the aim of this thesis is to investigate the dynamic behavior of an HTHP integrated into an industrial automotive paint shop. This thesis analyzes an automotive paint shop owned by GEICO S.p.A., which is currently in the design phase. The reference configuration which had been selected in the design phase for such paint shop uses an HTHP to supply two main ovens, while integrating an efficient heat recovery system to pre-heat the fresh ambient air to be supplied to specific air-seal ovens and also supply the required thermal power for another lower-temperature oven. A dynamic virtual plant model was therefore developed using the Modelica language in the Open-Modelica environment to further explore the controllability of the plant under off-design conditions. Such model was initially verified through physical-consistency checks and comparison with the available nominal design data. The developed model showed acceptable accuracy in the nominal full-load condition, while remaining stable in dynamic partial-load operation conditions. Therefore, the adopted control strategy proved capable of keeping the oven temperatures close to their target values while limiting overshoot in the main HTHP variables. The study also shows that hydraulic thermal inertia plays an important role in smoothing the transient response, confirming that the interaction between the heat pump, the hydraulic network, and the oven system cannot be adequately described by a purely steady-state approach.

Le pompe di calore ad alta temperatura (HTHP) rappresentano soluzioni promettenti per la riduzione del consumo di combustibili fossili nell’approvvigionamento termico industriale. Tuttavia, l’integrazione delle HTHP negli impianti di verniciatura automobilistica è stata studiata principalmente in condizioni stazionarie, mentre gli impianti reali operano a tassi di produzione variabili e con una significativa inerzia termica. Pertanto, l’obiettivo di questa tesi è quello di studiare il comportamento dinamico di una HTHP integrata in un impianto di verniciatura automobilistica industriale. La tesi analizza un impianto di verniciatura automobilistica appartenente alla GEICO S.P.A., attualmente in fase di progettazione. La configurazione di riferimento selezionata in fase di progettazione per tale impianto prevede l’utilizzo di una HTHP per alimentare due forni principali, integrando al contempo un efficiente sistema di recupero del calore per preriscaldare l’aria ambiente da immettere in specifici forni a tenuta d’aria e per fornire la potenza termica necessaria a un altro forno a temperatura inferiore. È stato quindi sviluppato un modello virtuale dinamico dell’impianto utilizzando il linguaggio di simulazione Open-Modelica per esplorare ulteriormente la controllabilità dell’impianto in condizioni non di progetto. Tale modello è stato inizialmente verificato mediante controlli di coerenza fisica e confronto con i dati di progetto nominali disponibili. Il modello sviluppato ha mostrato un’accuratezza accettabile nelle condizioni nominali di pieno carico, rimanendo stabile nelle condizioni operative dinamiche a carico parziale. Pertanto, la strategia di controllo adottata si è dimostrata efficace nel mantenere le temperature del forno vicine ai valori target, limitando al contempo il superamento dei principali indicatori HTHP. Lo studio ha inoltre evidenziato che l’inerzia termica idraulica gioca un ruolo importante nell’attenuare la risposta transitoria, confermando che l’interazione tra la pompa di calore, la rete idraulica e il sistema del forno non può essere descritta adeguatamente da un approccio puramente stazionario.

Study the dynamic behavior of High-Temperature Heat Pump in an industrial automotive paint shop

GHAMGOSAR, MAHSA
2025/2026

Abstract

High-temperature heat pumps (HTHPs) are promising solutions for reducing fossil-fuel consumption in industrial heat supply. However, the integration of HTHPs in automotive paint shops has mainly been studied under steady-state conditions, while real plants operate under variable production rates and significant thermal inertia. Therefore, the aim of this thesis is to investigate the dynamic behavior of an HTHP integrated into an industrial automotive paint shop. This thesis analyzes an automotive paint shop owned by GEICO S.p.A., which is currently in the design phase. The reference configuration which had been selected in the design phase for such paint shop uses an HTHP to supply two main ovens, while integrating an efficient heat recovery system to pre-heat the fresh ambient air to be supplied to specific air-seal ovens and also supply the required thermal power for another lower-temperature oven. A dynamic virtual plant model was therefore developed using the Modelica language in the Open-Modelica environment to further explore the controllability of the plant under off-design conditions. Such model was initially verified through physical-consistency checks and comparison with the available nominal design data. The developed model showed acceptable accuracy in the nominal full-load condition, while remaining stable in dynamic partial-load operation conditions. Therefore, the adopted control strategy proved capable of keeping the oven temperatures close to their target values while limiting overshoot in the main HTHP variables. The study also shows that hydraulic thermal inertia plays an important role in smoothing the transient response, confirming that the interaction between the heat pump, the hydraulic network, and the oven system cannot be adequately described by a purely steady-state approach.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Le pompe di calore ad alta temperatura (HTHP) rappresentano soluzioni promettenti per la riduzione del consumo di combustibili fossili nell’approvvigionamento termico industriale. Tuttavia, l’integrazione delle HTHP negli impianti di verniciatura automobilistica è stata studiata principalmente in condizioni stazionarie, mentre gli impianti reali operano a tassi di produzione variabili e con una significativa inerzia termica. Pertanto, l’obiettivo di questa tesi è quello di studiare il comportamento dinamico di una HTHP integrata in un impianto di verniciatura automobilistica industriale. La tesi analizza un impianto di verniciatura automobilistica appartenente alla GEICO S.P.A., attualmente in fase di progettazione. La configurazione di riferimento selezionata in fase di progettazione per tale impianto prevede l’utilizzo di una HTHP per alimentare due forni principali, integrando al contempo un efficiente sistema di recupero del calore per preriscaldare l’aria ambiente da immettere in specifici forni a tenuta d’aria e per fornire la potenza termica necessaria a un altro forno a temperatura inferiore. È stato quindi sviluppato un modello virtuale dinamico dell’impianto utilizzando il linguaggio di simulazione Open-Modelica per esplorare ulteriormente la controllabilità dell’impianto in condizioni non di progetto. Tale modello è stato inizialmente verificato mediante controlli di coerenza fisica e confronto con i dati di progetto nominali disponibili. Il modello sviluppato ha mostrato un’accuratezza accettabile nelle condizioni nominali di pieno carico, rimanendo stabile nelle condizioni operative dinamiche a carico parziale. Pertanto, la strategia di controllo adottata si è dimostrata efficace nel mantenere le temperature del forno vicine ai valori target, limitando al contempo il superamento dei principali indicatori HTHP. Lo studio ha inoltre evidenziato che l’inerzia termica idraulica gioca un ruolo importante nell’attenuare la risposta transitoria, confermando che l’interazione tra la pompa di calore, la rete idraulica e il sistema del forno non può essere descritta adeguatamente da un approccio puramente stazionario.
File allegati
File Dimensione Formato  
2026_07_Ghamgosar.pdf

non accessibile

Descrizione: Master thesis document
Dimensione 7.44 MB
Formato Adobe PDF
7.44 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261038