Workers exposed to vibrations may develop, over time, Hand-Arm Vibration Syndrome (HAVS), a disease that causes a narrowing of the blood vessels in the hands, resulting in discomfort and pain. Currently, the diagnosis of the disease is performed using complex equipment in specialized facilities, by specialized personnel and requires time; therefore, alternative methods are being investigated to give workers the opportunity to continuously monitor, directly in the workplace, the development of the disease. In a previous study, a prototype device was developed to measure skin-contact removed thermal power, since thermal power is assumed to be closely related to finger temperature and to the vascular response assessed during cold provocation tests, which currently represent the diagnostic standard. In this thesis, the prototype was further developed and validated into a functional device for workers exposed to vibration. The developed instrument is lightweight, and compact (900g, 150x150x112 mm) and allows the measurement of the thermal power between the patient’s finger and a cold surface at a controlled temperature; the device also measures the force exerted on the sensor, because this could influence the thermal power measurement. The device developed proved to be reliable during testing and its measurements are repeatable, both during use on the same day for extended periods, and during short daily uses distributed over a period of a few months, coefficient of variation (CV) for thermal power measurements remained below 5%. It is also characterized by ease of use, even for non-specialized personnel. The first analysis, carried out on the data obtained with the device, showed a linear correlation between the initial temperature of the patient’s finger and the thermal power values between the finger and the device (for every additional degree Celsius in finger temperature at the beginning of the test, the average thermal power increases by 0.0156 W); whereas no satisfactory relationship was observed between the pressure exerted on the sensor and thermal power values. The developed device was also preliminarily tested in a hospital setting on healthy volunteers, in parallel with strain-gauge plethysmography, showing a significant correlation between selected thermal parameters and finger blood flow (FBF), independently of age, sex, BMI, and ambient temperature. No tests have yet been carried out on patients affected by the syndrome, and this represents the next step in the research.

I lavoratori esposti a vibrazioni possono sviluppare, con il passare del tempo, la Hand Arm Vibration Syndrome (HAV), una malattia che induce un restringimento dei vasi sanguigni nelle mani, provocando fastidi e dolori. Attualmente la diagnosi della malattia viene effettuata con macchinari complessi in strutture specializzate, da personale specializzato e richiede tempo; si stanno quindi studiando metodi alternativi per dare ai lavoratori la possibilità di monitorare continuamente, direttamente nelle aziende, lo svilupparsi della malattia. In uno studio precedente è stato costruito un prototipo di dispositivo per misurare la potenza termica rimossa mediante contatto cutaneo, questo perché la potenza termica si suppone essere strettamente legata alla temperatura del dito e alla risposta vascolare valutata durante i test del freddo, che sono l’attuale standard diagnostico. In questa tesi, il prototipo è stato ulteriormente sviluppato, validato e reso un dispositivo funzionante per i lavoratori esposti a vibrazioni. Lo strumento sviluppato è leggero e compatto (900g, 150x150x112 mm) e permette di misurare la potenza termica scambiata tra il dito del paziente ed una superficie fredda a temperatura controllata; il dispositivo misura anche la forza esercitata sul sensore, perché questa potrebbe influenzare la misura della potenza termica. Il dispositivo realizzato è risultato essere affidabile durante i test e le sue misure sono ripetibili, sia durante l’utilizzo nella stessa giornata per periodi prolungati, sia nell’utilizzo per brevi periodi giornalieri distribuiti in un arco temporale di qualche mese, il coefficiente of variazione (CV) per le misure della potenza termica rimane inferiore al 5%; è inoltre caratterizzato dalla facilità di utilizzo, anche per personale non specializzato. Le prime analisi, realizzate sui dati ottenuti con il dispositivo, hanno mostrato una correlazione tra la temperatura iniziale del dito del paziente e i valori di potenza termica scambiata tra il dito ed il dispositivo (per ogni grado Celsius di incremento della temperatura del dito all’inizio della prova, la potenza termica media incrementa di 0.0156 W); mentre non è stata osservata una relazione soddisfacente tra pressione esercitata sul sensore e valori di potenza termica. Il dispositivo sviluppato è anche stato testato in ambito ospedaliero su volontari sani, in parallelo con la pletismografia strain-gauge, mostrando una correlazione significativa tra i parametri della potenza termica e il flusso ematico digitale (FBF), indipendentemente da età, sesso, BMI e dalla temperatura ambiente. Non sono ancora stati eseguiti test su pazienti malati e questo rappresenta il prossimo passo nella ricerca.

Design, development and validation of a diagnostic device for Hand-Arm Vibration Syndrome (HAVS)

Marazzi, Alessandro Maria
2025/2026

Abstract

Workers exposed to vibrations may develop, over time, Hand-Arm Vibration Syndrome (HAVS), a disease that causes a narrowing of the blood vessels in the hands, resulting in discomfort and pain. Currently, the diagnosis of the disease is performed using complex equipment in specialized facilities, by specialized personnel and requires time; therefore, alternative methods are being investigated to give workers the opportunity to continuously monitor, directly in the workplace, the development of the disease. In a previous study, a prototype device was developed to measure skin-contact removed thermal power, since thermal power is assumed to be closely related to finger temperature and to the vascular response assessed during cold provocation tests, which currently represent the diagnostic standard. In this thesis, the prototype was further developed and validated into a functional device for workers exposed to vibration. The developed instrument is lightweight, and compact (900g, 150x150x112 mm) and allows the measurement of the thermal power between the patient’s finger and a cold surface at a controlled temperature; the device also measures the force exerted on the sensor, because this could influence the thermal power measurement. The device developed proved to be reliable during testing and its measurements are repeatable, both during use on the same day for extended periods, and during short daily uses distributed over a period of a few months, coefficient of variation (CV) for thermal power measurements remained below 5%. It is also characterized by ease of use, even for non-specialized personnel. The first analysis, carried out on the data obtained with the device, showed a linear correlation between the initial temperature of the patient’s finger and the thermal power values between the finger and the device (for every additional degree Celsius in finger temperature at the beginning of the test, the average thermal power increases by 0.0156 W); whereas no satisfactory relationship was observed between the pressure exerted on the sensor and thermal power values. The developed device was also preliminarily tested in a hospital setting on healthy volunteers, in parallel with strain-gauge plethysmography, showing a significant correlation between selected thermal parameters and finger blood flow (FBF), independently of age, sex, BMI, and ambient temperature. No tests have yet been carried out on patients affected by the syndrome, and this represents the next step in the research.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
I lavoratori esposti a vibrazioni possono sviluppare, con il passare del tempo, la Hand Arm Vibration Syndrome (HAV), una malattia che induce un restringimento dei vasi sanguigni nelle mani, provocando fastidi e dolori. Attualmente la diagnosi della malattia viene effettuata con macchinari complessi in strutture specializzate, da personale specializzato e richiede tempo; si stanno quindi studiando metodi alternativi per dare ai lavoratori la possibilità di monitorare continuamente, direttamente nelle aziende, lo svilupparsi della malattia. In uno studio precedente è stato costruito un prototipo di dispositivo per misurare la potenza termica rimossa mediante contatto cutaneo, questo perché la potenza termica si suppone essere strettamente legata alla temperatura del dito e alla risposta vascolare valutata durante i test del freddo, che sono l’attuale standard diagnostico. In questa tesi, il prototipo è stato ulteriormente sviluppato, validato e reso un dispositivo funzionante per i lavoratori esposti a vibrazioni. Lo strumento sviluppato è leggero e compatto (900g, 150x150x112 mm) e permette di misurare la potenza termica scambiata tra il dito del paziente ed una superficie fredda a temperatura controllata; il dispositivo misura anche la forza esercitata sul sensore, perché questa potrebbe influenzare la misura della potenza termica. Il dispositivo realizzato è risultato essere affidabile durante i test e le sue misure sono ripetibili, sia durante l’utilizzo nella stessa giornata per periodi prolungati, sia nell’utilizzo per brevi periodi giornalieri distribuiti in un arco temporale di qualche mese, il coefficiente of variazione (CV) per le misure della potenza termica rimane inferiore al 5%; è inoltre caratterizzato dalla facilità di utilizzo, anche per personale non specializzato. Le prime analisi, realizzate sui dati ottenuti con il dispositivo, hanno mostrato una correlazione tra la temperatura iniziale del dito del paziente e i valori di potenza termica scambiata tra il dito ed il dispositivo (per ogni grado Celsius di incremento della temperatura del dito all’inizio della prova, la potenza termica media incrementa di 0.0156 W); mentre non è stata osservata una relazione soddisfacente tra pressione esercitata sul sensore e valori di potenza termica. Il dispositivo sviluppato è anche stato testato in ambito ospedaliero su volontari sani, in parallelo con la pletismografia strain-gauge, mostrando una correlazione significativa tra i parametri della potenza termica e il flusso ematico digitale (FBF), indipendentemente da età, sesso, BMI e dalla temperatura ambiente. Non sono ancora stati eseguiti test su pazienti malati e questo rappresenta il prossimo passo nella ricerca.
File allegati
File Dimensione Formato  
2026_7__Marazzi_Thesis.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Tesi Alessandro Marazzi
Dimensione 8.39 MB
Formato Adobe PDF
8.39 MB Adobe PDF   Visualizza/Apri
2026_7_Marazzi_Executive_Summary.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Executive Summary Alessandro Marazzi
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261150