The effect of riblet positioning on a transonic airfoil is investigated. A parametric RANS study is performed to assess the sensitivity of the airfoil performance, expressed through the lift-to-drag ratio, to the position of application of the control. The effect of locally optimal riblets is modelled in RANS by enforcing a properly defined partial slip boundary condition for velocity. Consistent with previous works, riblet presence is confirmed to reduce the skin friction and to modify the flow features by moving the shock towards the trailing edge. The suction side exhibits the highest sensitivity to the control application. The best-performing configurations are those situated in the front section, which induce the most significant alterations to the global flow features. The analysis performed at two different Reynolds numbers demonstrates a reduction in riblet effectiveness as the Reynolds number increases. At Re = 300000, the profile entirely covered by riblets features a variation in the lift-to-drag ratio of +7.4% and the partial coverage configuration with the best performance achieves +1.9%. These values diminish to +4.0% for the fully covered profile and +1.7% for the optimal partial coverage configuration at Re = 1000000. The adjoint equations to obtain the sensitivity of the aerodynamic efficiency to the application of a slip velocity at the wall are derived, establishing the theoretical framework for a fully automated optimization process.
Questa tesi studia l'effetto della posizione di applicazione di riblets su un profilo alare transonico tramite la risoluzione di RANS. La sensibilità delle prestazioni del profilo, espresse in termini di efficienza aerodinamica, rispetto alla posizione di applicazione del controllo è valutata attraverso uno studio parametrico. L'effetto di riblets localmente ottimali è implementato in un solutore RANS imponendo uno slip parziale a parete tramite un'opportuna condizione al contorno per la velocità. Coerentemente con la letteratura, i risultati confermano che la presenza di riblets riduce l'attrito superficiale e modifica le caratteristiche del flusso, spostando l'onda d'urto verso il bordo d'uscita. Il dorso si dimostra essere la parte più sensibile all'applicazione del controllo: le configurazioni con le prestazioni migliori sono quelle situate nella parte anteriore che causano le maggiori alterazioni del flusso intorno al profilo. Estendendo l'analisi a due diversi numeri di Reynolds, si osserva che l'efficacia del controllo si riduce all'aumentare di tale parametro. A Re = 300000, il profilo interamente coperto di riblets registra un incremento di efficienza pari a +7.4%, mentre la migliore configurazione a copertura parziale raggiunge +1.9%. A Re = 1000000, questi valori scendono rispettivamente a +4.0% per il profilo completamente controllato e a +1.7% per la configurazione a copertura parziale ottima. Infine sono derivate le equazioni aggiunte necessarie per ricavare la sensibilità dell'efficienza all'imposizione di una velocità di slip a parete, stabilendo così le fondamenta teoriche per un futuro processo di ottimizzazione completamente automatizzato.
Enhancing transonic airfoil efficiency through localized friction reduction
Alloggio, Davide
2025/2026
Abstract
The effect of riblet positioning on a transonic airfoil is investigated. A parametric RANS study is performed to assess the sensitivity of the airfoil performance, expressed through the lift-to-drag ratio, to the position of application of the control. The effect of locally optimal riblets is modelled in RANS by enforcing a properly defined partial slip boundary condition for velocity. Consistent with previous works, riblet presence is confirmed to reduce the skin friction and to modify the flow features by moving the shock towards the trailing edge. The suction side exhibits the highest sensitivity to the control application. The best-performing configurations are those situated in the front section, which induce the most significant alterations to the global flow features. The analysis performed at two different Reynolds numbers demonstrates a reduction in riblet effectiveness as the Reynolds number increases. At Re = 300000, the profile entirely covered by riblets features a variation in the lift-to-drag ratio of +7.4% and the partial coverage configuration with the best performance achieves +1.9%. These values diminish to +4.0% for the fully covered profile and +1.7% for the optimal partial coverage configuration at Re = 1000000. The adjoint equations to obtain the sensitivity of the aerodynamic efficiency to the application of a slip velocity at the wall are derived, establishing the theoretical framework for a fully automated optimization process.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_07_Alloggio.pdf
accessibile in internet per tutti
Descrizione: Testo della tesi
Dimensione
3.21 MB
Formato
Adobe PDF
|
3.21 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/261178