Atmospheric gusts introduce highly unsteady aerodynamic loads that can impact both aircraft structures and passenger comfort. Because conventional mechanical control surfaces often lack the timely response necessary to counteract these high-frequency disturbances, advanced active flow control systems offer a promising alternative. This thesis addresses this need by investigating the efficiency of a trailing-edge Coanda jet actuator integrated into a standard NACA0012 airfoil. Simulations were performed using the software SU2 solving the URANS equations. First, an airfoil subjected to a 1-cos profile gust was simulated to be used as baseline for future comparisons. Then, two different control strategies were implemented and compared to determine the most effective one in alleviating gust loads. From the obtained results, a Coanda trailing-edge with a dual-jet strategy proved to be the optimal solution. In order to for this configuration to work optimally, it was found that jets activation time is a critical factor. An 85% alleviation (compared to the baseline case) for gust wavelengths ranging from 5c to 25c can only be achieved when the jets activate before the gust reaches the leading edge of the airfoil.

Le raffiche atmosferiche introducono carichi aerodinamici fortemente non stazionari che possono avere un impatto sia sulle strutture dei velivoli sia sul comfort dei passeggeri. Poiché le superfici di controllo meccaniche convenzionali spesso mancano della risposta tempestiva necessaria per contrastare questi disturbi ad alta frequenza, i sistemi avanzati di controllo attivo del flusso offrono un’alternativa promettente. Questa tesi risponde a tale esigenza analizzando l’efficienza di un attuatore a getto Coanda al bordo d’uscita integrato in un profilo alare NACA0012 standard.Le simulazioni sono state eseguite uti- lizzando il software SU2 per risolvere le equazioni URANS. Inizialmente, è stato simulato un profilo alare soggetto a una raffica con profilo 1-cos da utilizzare come riferimento per i confronti futuri. Successivamente, sono state implementate e confrontate due diverse strategie di controllo per determinare la più efficace nell’attenuazione dei carichi da raf- fica.Dai risultati ottenuti, un bordo d’uscita Coanda con una strategia a doppio getto si è rivelato la soluzione ottimale. Affinché questa configurazione funzioni in modo ottimale, è emerso che il tempo di attivazione dei getti è un fattore critico. Un’attenuazione dell’85% (rispetto al caso di riferimento) per lunghezze d’onda della raffica comprese tra 5c e 25c può essere ottenuta solo quando i getti si attivano prima che la raffica raggiunga il bordo d’attacco del profilo.

NACA0012 gust loading alleviation control via Coanda-jets feedback control

BUITRAGO BERNAL, SANTIAGO
2025/2026

Abstract

Atmospheric gusts introduce highly unsteady aerodynamic loads that can impact both aircraft structures and passenger comfort. Because conventional mechanical control surfaces often lack the timely response necessary to counteract these high-frequency disturbances, advanced active flow control systems offer a promising alternative. This thesis addresses this need by investigating the efficiency of a trailing-edge Coanda jet actuator integrated into a standard NACA0012 airfoil. Simulations were performed using the software SU2 solving the URANS equations. First, an airfoil subjected to a 1-cos profile gust was simulated to be used as baseline for future comparisons. Then, two different control strategies were implemented and compared to determine the most effective one in alleviating gust loads. From the obtained results, a Coanda trailing-edge with a dual-jet strategy proved to be the optimal solution. In order to for this configuration to work optimally, it was found that jets activation time is a critical factor. An 85% alleviation (compared to the baseline case) for gust wavelengths ranging from 5c to 25c can only be achieved when the jets activate before the gust reaches the leading edge of the airfoil.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Le raffiche atmosferiche introducono carichi aerodinamici fortemente non stazionari che possono avere un impatto sia sulle strutture dei velivoli sia sul comfort dei passeggeri. Poiché le superfici di controllo meccaniche convenzionali spesso mancano della risposta tempestiva necessaria per contrastare questi disturbi ad alta frequenza, i sistemi avanzati di controllo attivo del flusso offrono un’alternativa promettente. Questa tesi risponde a tale esigenza analizzando l’efficienza di un attuatore a getto Coanda al bordo d’uscita integrato in un profilo alare NACA0012 standard.Le simulazioni sono state eseguite uti- lizzando il software SU2 per risolvere le equazioni URANS. Inizialmente, è stato simulato un profilo alare soggetto a una raffica con profilo 1-cos da utilizzare come riferimento per i confronti futuri. Successivamente, sono state implementate e confrontate due diverse strategie di controllo per determinare la più efficace nell’attenuazione dei carichi da raf- fica.Dai risultati ottenuti, un bordo d’uscita Coanda con una strategia a doppio getto si è rivelato la soluzione ottimale. Affinché questa configurazione funzioni in modo ottimale, è emerso che il tempo di attivazione dei getti è un fattore critico. Un’attenuazione dell’85% (rispetto al caso di riferimento) per lunghezze d’onda della raffica comprese tra 5c e 25c può essere ottenuta solo quando i getti si attivano prima che la raffica raggiunga il bordo d’attacco del profilo.
File allegati
File Dimensione Formato  
2026_07_BuitragoBernal_Executive_Summary_02.pdf

accessibile in internet per tutti

Descrizione: Executive summary
Dimensione 2.62 MB
Formato Adobe PDF
2.62 MB Adobe PDF Visualizza/Apri
2026_07_BuitragoBernal_Thesis_01.pdf

accessibile in internet per tutti

Descrizione: Thesis text
Dimensione 8.1 MB
Formato Adobe PDF
8.1 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261230