Continuous fenceline monitoring of odour emissions is increasingly required by the evolving regulatory framework (IED 2024/1785), and Instrumental Odour Monitoring Systems (IOMS), or electronic noses, are its reference technology. Their large-scale, permanent deployment, however, faces two practical obstacles: the interpretability of the monitoring output — conventionally reduced to a window-averaged fraction of time per odour class, ill-suited to short or sustained episodes and hard to reconcile with citizen reports — and the operational cost of the sensing hardware, whose metal-oxide arrays must be kept permanently powered at their operating temperature. This thesis addresses both through two complementary field case studies, aiming to optimise the IOMS operational protocol and to inform the technical standards under development (UNI 11761:2023; CEN/TC 264/WG 41). The first case study, based on one year of data from a commercial nose at an anaerobic-digestion plant fenceline, reframes the monitoring output as a two-level scheme. A first level detects, in real time, when the multivariate sensor response departs from an adaptive no-odour baseline — a rolling per-channel z-normalisation feeding a fixed-loading PCA, on whose first principal score a continuously updated air threshold (AT) is defined — returning for every event its onset, duration and intensity; a second level attributes each detected event to its source. The detector flags 7.7 % of the record against 5.2 % for the conventional percentage-of-odour metric, whose seasonal profile it reproduces in summer while remaining sensitive in autumn, when that metric falls to near-zero; the source attribution (0.76 balanced accuracy) matches the 75 % of the conventional approach. The resulting output is independent of any integration window, directly comparable with citizen reports and usable to trigger alarms and operational procedures. The second case study characterises a compact modular prototype that integrates a six-sensor analog metal-oxide array with a temperature- modulated digital sensor (SGP4X). On 132 controlled samples spanning four landfill sources and seventeen independent sessions, a group-wise 1 cross-validated pipeline reaches 86.9 % balanced accuracy (k-NN); the hybrid configuration attains the same source discrimination as the metal- oxide array alone but with significantly fewer features — a direct gain in compactness, power and cost that makes distributed, multi-point networks feasible. The residual error is a structurally interpretable biogas– fresh-waste confusion, and a dedicated regression of biogas odour concentration attains R2 = 0.634 (MAE 18.7 OUe) on a fully held-out campaign, every prediction within the EN 13725 olfactometric band. Together, the two studies show that methodologically lightweight interventions at the two ends of the IOMS chain — event-based interpretation and feature-efficient hybrid sensing — deliver field-useful performance while jointly improving the usability of the monitoring output and the scalability of the sensing hardware.

Il monitoraggio continuo delle emissioni odorigene al confine di impianto è sempre più richiesto dall'evolversi del quadro normativo (IED 2024/1785), e gli Instrumental Odour Monitoring Systems (IOMS), o nasi elettronici, ne sono la tecnologia di riferimento. Il loro impiego permanente su larga scala incontra però due ostacoli pratici: l'interpretabilità dell'output di monitoraggio — convenzionalmente ridotto a una frazione di tempo per classe odorigena mediata su finestra, poco adatta a episodi brevi o prolungati e difficilmente conciliabile con le segnalazioni dei cittadini — e il costo operativo dell'hardware sensoristico, i cui array a ossido metallico devono restare costantemente alimentati alla loro temperatura di esercizio. Questa tesi affronta entrambi attraverso due casi studio complementari in campo, con l'obiettivo di ottimizzare il protocollo operativo degli IOMS e di contribuire agli standard tecnici in fase di sviluppo (UNI 11761:2023; CEN/TC 264/WG 41). Il primo caso studio, basato su un anno di dati di un naso commerciale al confine di un impianto di digestione anaerobica, reimposta l'output di monitoraggio come uno schema a due livelli. Un primo livello rileva, in tempo reale, quando la risposta multivariata dei sensori si discosta da una baseline adattiva di assenza di odore — una z-normalizzazione mobile per canale che alimenta una PCA a loading fissi, sul cui primo score principale è definita una soglia d'aria (AT) aggiornata in continuo — restituendo per ogni evento inizio, durata e intensità; un secondo livello attribuisce ciascun evento rilevato alla sua sorgente. Il rilevatore segnala il 7,7 % del record contro il 5,2 % della metrica convenzionale di percentuale di odore, di cui riproduce il profilo stagionale in estate rimanendo però sensibile in autunno, quando quella metrica scende a quasi zero; l'attribuzione della sorgente (balanced accuracy 0,76) eguaglia il 75 % dell'approccio convenzionale. L'output risultante è indipendente da qualsiasi finestra di integrazione, direttamente confrontabile con le segnalazioni dei cittadini e utilizzabile per attivare allarmi e procedure operative. Il secondo caso studio caratterizza un prototipo modulare compatto che integra un array analogico a sei sensori a ossido metallico con un sensore digitale a modulazione di temperatura (SGP4X). Su 132 campioni controllati, relativi a quattro sorgenti di discarica e diciassette sessioni indipendenti, una pipeline validata in cross-validation group-wise raggiunge l'86,9 % di accuratezza bilanciata (k-NN); la configurazione ibrida ottiene la stessa discriminazione delle sorgenti del solo array a ossido metallico ma con un numero di feature significativamente inferiore — un guadagno diretto in compattezza, consumi e costo che rende praticabili reti distribuite e multipunto. L'errore residuo è una confusione strutturalmente interpretabile tra biogas e rifiuto fresco, e una regressione dedicata della concentrazione di odore del biogas raggiunge R² = 0,634 (MAE 18,7 OUe) su una campagna completamente esclusa dall'addestramento, con ogni predizione entro la banda olfattometrica della EN 13725. Nel complesso, i due studi mostrano che interventi metodologicamente leggeri ai due estremi della catena IOMS — interpretazione basata sugli eventi e sensing ibrido efficiente nelle feature — offrono prestazioni utili sul campo, migliorando al contempo la fruibilità dell'output di monitoraggio e la scalabilità dell'hardware sensoristico.

Optimization of the IOMS use protocol for environmental monitoring

Cali', Marco
2025/2026

Abstract

Continuous fenceline monitoring of odour emissions is increasingly required by the evolving regulatory framework (IED 2024/1785), and Instrumental Odour Monitoring Systems (IOMS), or electronic noses, are its reference technology. Their large-scale, permanent deployment, however, faces two practical obstacles: the interpretability of the monitoring output — conventionally reduced to a window-averaged fraction of time per odour class, ill-suited to short or sustained episodes and hard to reconcile with citizen reports — and the operational cost of the sensing hardware, whose metal-oxide arrays must be kept permanently powered at their operating temperature. This thesis addresses both through two complementary field case studies, aiming to optimise the IOMS operational protocol and to inform the technical standards under development (UNI 11761:2023; CEN/TC 264/WG 41). The first case study, based on one year of data from a commercial nose at an anaerobic-digestion plant fenceline, reframes the monitoring output as a two-level scheme. A first level detects, in real time, when the multivariate sensor response departs from an adaptive no-odour baseline — a rolling per-channel z-normalisation feeding a fixed-loading PCA, on whose first principal score a continuously updated air threshold (AT) is defined — returning for every event its onset, duration and intensity; a second level attributes each detected event to its source. The detector flags 7.7 % of the record against 5.2 % for the conventional percentage-of-odour metric, whose seasonal profile it reproduces in summer while remaining sensitive in autumn, when that metric falls to near-zero; the source attribution (0.76 balanced accuracy) matches the 75 % of the conventional approach. The resulting output is independent of any integration window, directly comparable with citizen reports and usable to trigger alarms and operational procedures. The second case study characterises a compact modular prototype that integrates a six-sensor analog metal-oxide array with a temperature- modulated digital sensor (SGP4X). On 132 controlled samples spanning four landfill sources and seventeen independent sessions, a group-wise 1 cross-validated pipeline reaches 86.9 % balanced accuracy (k-NN); the hybrid configuration attains the same source discrimination as the metal- oxide array alone but with significantly fewer features — a direct gain in compactness, power and cost that makes distributed, multi-point networks feasible. The residual error is a structurally interpretable biogas– fresh-waste confusion, and a dedicated regression of biogas odour concentration attains R2 = 0.634 (MAE 18.7 OUe) on a fully held-out campaign, every prediction within the EN 13725 olfactometric band. Together, the two studies show that methodologically lightweight interventions at the two ends of the IOMS chain — event-based interpretation and feature-efficient hybrid sensing — deliver field-useful performance while jointly improving the usability of the monitoring output and the scalability of the sensing hardware.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Il monitoraggio continuo delle emissioni odorigene al confine di impianto è sempre più richiesto dall'evolversi del quadro normativo (IED 2024/1785), e gli Instrumental Odour Monitoring Systems (IOMS), o nasi elettronici, ne sono la tecnologia di riferimento. Il loro impiego permanente su larga scala incontra però due ostacoli pratici: l'interpretabilità dell'output di monitoraggio — convenzionalmente ridotto a una frazione di tempo per classe odorigena mediata su finestra, poco adatta a episodi brevi o prolungati e difficilmente conciliabile con le segnalazioni dei cittadini — e il costo operativo dell'hardware sensoristico, i cui array a ossido metallico devono restare costantemente alimentati alla loro temperatura di esercizio. Questa tesi affronta entrambi attraverso due casi studio complementari in campo, con l'obiettivo di ottimizzare il protocollo operativo degli IOMS e di contribuire agli standard tecnici in fase di sviluppo (UNI 11761:2023; CEN/TC 264/WG 41). Il primo caso studio, basato su un anno di dati di un naso commerciale al confine di un impianto di digestione anaerobica, reimposta l'output di monitoraggio come uno schema a due livelli. Un primo livello rileva, in tempo reale, quando la risposta multivariata dei sensori si discosta da una baseline adattiva di assenza di odore — una z-normalizzazione mobile per canale che alimenta una PCA a loading fissi, sul cui primo score principale è definita una soglia d'aria (AT) aggiornata in continuo — restituendo per ogni evento inizio, durata e intensità; un secondo livello attribuisce ciascun evento rilevato alla sua sorgente. Il rilevatore segnala il 7,7 % del record contro il 5,2 % della metrica convenzionale di percentuale di odore, di cui riproduce il profilo stagionale in estate rimanendo però sensibile in autunno, quando quella metrica scende a quasi zero; l'attribuzione della sorgente (balanced accuracy 0,76) eguaglia il 75 % dell'approccio convenzionale. L'output risultante è indipendente da qualsiasi finestra di integrazione, direttamente confrontabile con le segnalazioni dei cittadini e utilizzabile per attivare allarmi e procedure operative. Il secondo caso studio caratterizza un prototipo modulare compatto che integra un array analogico a sei sensori a ossido metallico con un sensore digitale a modulazione di temperatura (SGP4X). Su 132 campioni controllati, relativi a quattro sorgenti di discarica e diciassette sessioni indipendenti, una pipeline validata in cross-validation group-wise raggiunge l'86,9 % di accuratezza bilanciata (k-NN); la configurazione ibrida ottiene la stessa discriminazione delle sorgenti del solo array a ossido metallico ma con un numero di feature significativamente inferiore — un guadagno diretto in compattezza, consumi e costo che rende praticabili reti distribuite e multipunto. L'errore residuo è una confusione strutturalmente interpretabile tra biogas e rifiuto fresco, e una regressione dedicata della concentrazione di odore del biogas raggiunge R² = 0,634 (MAE 18,7 OUe) su una campagna completamente esclusa dall'addestramento, con ogni predizione entro la banda olfattometrica della EN 13725. Nel complesso, i due studi mostrano che interventi metodologicamente leggeri ai due estremi della catena IOMS — interpretazione basata sugli eventi e sensing ibrido efficiente nelle feature — offrono prestazioni utili sul campo, migliorando al contempo la fruibilità dell'output di monitoraggio e la scalabilità dell'hardware sensoristico.
File allegati
File Dimensione Formato  
2026_07_Cali_Tesi.pdf

non accessibile

Descrizione: Tesi
Dimensione 8.66 MB
Formato Adobe PDF
8.66 MB Adobe PDF   Visualizza/Apri
2026_07_Cali_Executive Summary.pdf

non accessibile

Descrizione: Executive Summary
Dimensione 2.77 MB
Formato Adobe PDF
2.77 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261278