Cholangiocarcinoma (CCA) is a highly aggressive malignancy characterized by poor prognosis, limited therapeutic options, and a complex tumor microenvironment (TME) that promotes immune evasion and treatment resistance. Although immune checkpoint inhibitors have recently expanded treatment opportunities, clinical responses remain highly heterogeneous, highlighting the need to better understand the mechanisms that govern treatment response and resistance. In this work, a previously established CCA-on-chip model was optimized and validated as a biomimetic platform for studying tumor-immune interactions and predicting patient-specific therapeutic responses. The PDMS-based microfluidic device comprises three interconnected channels containing primary tumor cells, cancer-associated fibroblasts (CAFs), endothelial cells, and T cells. Tumor and stromal compartments were embedded within a collagen-fibrin hydrogel to reproduce the native extracellular matrix. Device design and fabrication were performed at Politecnico di Milano, while biological experiments were conducted at Humanitas Clinical and Research Center. The ability of the platform to recapitulate the patient-specific TME was first assessed by comparing on-chip tumor-stroma architecture and immune-cell infiltration with matched CCA tissues. Despite identical initial seeding conditions, cells spontaneously reorganized within the device, reproducing the histological organization observed in vivo. The platform was subsequently used to evaluate responses to Gemcitabine, Cisplatin, and Durvalumab in patient-derived samples characterized by different PD-L1 expression levels. On-chip therapeutic responses accurately mirrored clinical outcomes, with the PD-L1-high model responding to treatment and the PD-L1-low model displaying resistance. Finally, a pressure-driven recirculating perfusion system was integrated to introduce physiological fluid flow and enable vascular delivery of immune cells and therapeutic agents. This implementation improved the physiological relevance of the model while reducing reagent consumption, standardizing experimental procedures, and increasing reproducibility. Overall, the optimized CCA-on-chip platform represents a promising tool for personalized drug screening and precision oncology applications.

Il colangiocarcinoma (CCA) è una neoplasia altamente aggressiva caratterizzata da una prognosi sfavorevole, opzioni terapeutiche limitate e da un complesso microambiente tumorale (TME) che favorisce l’evasione immunitaria e la resistenza ai trattamenti. Sebbene l’introduzione degli inibitori dei checkpoint immunitari abbia recentemente ampliato le possibilità terapeutiche disponibili, le risposte cliniche rimangono estremamente eterogenee, evidenziando la necessità di comprendere meglio i meccanismi biologici alla base della sensibilità e della resistenza alle terapie. In questo lavoro di tesi, un modello di CCA-on-chip precedentemente sviluppato è stato ottimizzato e validato come piattaforma biomimetica per lo studio delle interazioni tra tumore e sistema immunitario e per la previsione della risposta terapeutica a livello paziente-specifico. Il dispositivo microfluidico, realizzato in polidimetilsilossano (PDMS), è costituito da tre canali interconnessi contenenti cellule tumorali primarie, fibroblasti associati al tumore (CAFs), cellule endoteliali e linfociti T. Le componenti tumorali e stromali sono state inglobate in un idrogelo di collagene-fibrina al fine di riprodurre la matrice extracellulare nativa. La progettazione e la fabbricazione dei dispositivi sono state eseguite presso il Politecnico di Milano, mentre gli esperimenti biologici sono stati condotti presso l’Humanitas Clinical and Research Center di Rozzano. La capacità della piattaforma di ricapitolare il microambiente tumorale paziente-specifico è stata inizialmente valutata confrontando l’architettura tumore-stroma e i pattern di infiltrazione immunitaria osservati on-chip con quelli presenti nei corrispondenti tessuti di colangiocarcinoma intraepatico (iCCA). Nonostante condizioni iniziali di semina identiche, le diverse popolazioni cellulari si sono spontaneamente riorganizzate all’interno del dispositivo, riproducendo fedelmente l’organizzazione istologica osservata in vivo. Successivamente, la piattaforma è stata impiegata per valutare la risposta alla combinazione terapeutica Gemcitabina, Cisplatino e Durvalumab utilizzando campioni derivati da pazienti caratterizzati da differenti livelli di espressione di PD-L1. Le risposte terapeutiche osservate su chip hanno rispecchiato accuratamente gli esiti clinici dei pazienti, con il modello ad elevata espressione di PD-L1 sensibile al trattamento e quello a bassa espressione resistente alla terapia. Infine, è stato integrato un sistema di perfusione ricircolante a controllo di pressione per introdurre un flusso fisiologico e consentire la somministrazione vascolare di cellule immunitarie e farmaci. Questa implementazione ha aumentato la rilevanza fisiologica del modello, riducendo al contempo il consumo di reagenti, standardizzando le procedure sperimentali e migliorandone la riproducibilità. Nel complesso, la piattaforma CCA-on-chip ottimizzata rappresenta uno strumento promettente per lo screening farmacologico personalizzato e per future applicazioni nell’ambito dell’oncologia di precisione.

Advancing CCA-on-chip technology: dynamic microfluidic co-culture to explore immuno-chemotherapy synergies in cholangiocarcinoma

Bagatti, Nadia
2025/2026

Abstract

Cholangiocarcinoma (CCA) is a highly aggressive malignancy characterized by poor prognosis, limited therapeutic options, and a complex tumor microenvironment (TME) that promotes immune evasion and treatment resistance. Although immune checkpoint inhibitors have recently expanded treatment opportunities, clinical responses remain highly heterogeneous, highlighting the need to better understand the mechanisms that govern treatment response and resistance. In this work, a previously established CCA-on-chip model was optimized and validated as a biomimetic platform for studying tumor-immune interactions and predicting patient-specific therapeutic responses. The PDMS-based microfluidic device comprises three interconnected channels containing primary tumor cells, cancer-associated fibroblasts (CAFs), endothelial cells, and T cells. Tumor and stromal compartments were embedded within a collagen-fibrin hydrogel to reproduce the native extracellular matrix. Device design and fabrication were performed at Politecnico di Milano, while biological experiments were conducted at Humanitas Clinical and Research Center. The ability of the platform to recapitulate the patient-specific TME was first assessed by comparing on-chip tumor-stroma architecture and immune-cell infiltration with matched CCA tissues. Despite identical initial seeding conditions, cells spontaneously reorganized within the device, reproducing the histological organization observed in vivo. The platform was subsequently used to evaluate responses to Gemcitabine, Cisplatin, and Durvalumab in patient-derived samples characterized by different PD-L1 expression levels. On-chip therapeutic responses accurately mirrored clinical outcomes, with the PD-L1-high model responding to treatment and the PD-L1-low model displaying resistance. Finally, a pressure-driven recirculating perfusion system was integrated to introduce physiological fluid flow and enable vascular delivery of immune cells and therapeutic agents. This implementation improved the physiological relevance of the model while reducing reagent consumption, standardizing experimental procedures, and increasing reproducibility. Overall, the optimized CCA-on-chip platform represents a promising tool for personalized drug screening and precision oncology applications.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Il colangiocarcinoma (CCA) è una neoplasia altamente aggressiva caratterizzata da una prognosi sfavorevole, opzioni terapeutiche limitate e da un complesso microambiente tumorale (TME) che favorisce l’evasione immunitaria e la resistenza ai trattamenti. Sebbene l’introduzione degli inibitori dei checkpoint immunitari abbia recentemente ampliato le possibilità terapeutiche disponibili, le risposte cliniche rimangono estremamente eterogenee, evidenziando la necessità di comprendere meglio i meccanismi biologici alla base della sensibilità e della resistenza alle terapie. In questo lavoro di tesi, un modello di CCA-on-chip precedentemente sviluppato è stato ottimizzato e validato come piattaforma biomimetica per lo studio delle interazioni tra tumore e sistema immunitario e per la previsione della risposta terapeutica a livello paziente-specifico. Il dispositivo microfluidico, realizzato in polidimetilsilossano (PDMS), è costituito da tre canali interconnessi contenenti cellule tumorali primarie, fibroblasti associati al tumore (CAFs), cellule endoteliali e linfociti T. Le componenti tumorali e stromali sono state inglobate in un idrogelo di collagene-fibrina al fine di riprodurre la matrice extracellulare nativa. La progettazione e la fabbricazione dei dispositivi sono state eseguite presso il Politecnico di Milano, mentre gli esperimenti biologici sono stati condotti presso l’Humanitas Clinical and Research Center di Rozzano. La capacità della piattaforma di ricapitolare il microambiente tumorale paziente-specifico è stata inizialmente valutata confrontando l’architettura tumore-stroma e i pattern di infiltrazione immunitaria osservati on-chip con quelli presenti nei corrispondenti tessuti di colangiocarcinoma intraepatico (iCCA). Nonostante condizioni iniziali di semina identiche, le diverse popolazioni cellulari si sono spontaneamente riorganizzate all’interno del dispositivo, riproducendo fedelmente l’organizzazione istologica osservata in vivo. Successivamente, la piattaforma è stata impiegata per valutare la risposta alla combinazione terapeutica Gemcitabina, Cisplatino e Durvalumab utilizzando campioni derivati da pazienti caratterizzati da differenti livelli di espressione di PD-L1. Le risposte terapeutiche osservate su chip hanno rispecchiato accuratamente gli esiti clinici dei pazienti, con il modello ad elevata espressione di PD-L1 sensibile al trattamento e quello a bassa espressione resistente alla terapia. Infine, è stato integrato un sistema di perfusione ricircolante a controllo di pressione per introdurre un flusso fisiologico e consentire la somministrazione vascolare di cellule immunitarie e farmaci. Questa implementazione ha aumentato la rilevanza fisiologica del modello, riducendo al contempo il consumo di reagenti, standardizzando le procedure sperimentali e migliorandone la riproducibilità. Nel complesso, la piattaforma CCA-on-chip ottimizzata rappresenta uno strumento promettente per lo screening farmacologico personalizzato e per future applicazioni nell’ambito dell’oncologia di precisione.
File allegati
File Dimensione Formato  
2026_07_Bagatti_Executive_Summary.pdf

solo utenti autorizzati a partire dal 01/07/2027

Descrizione: Executive Summary
Dimensione 1.77 MB
Formato Adobe PDF
1.77 MB Adobe PDF   Visualizza/Apri
2026_07_Bagatti_Tesi.pdf

non accessibile

Descrizione: Tesi
Dimensione 7.82 MB
Formato Adobe PDF
7.82 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261308