The global transition toward a carbon-neutral energy sector is accelerating the deployment of nuclear power and has renewed the interest in Small Modular Reactors (SMRs). Among the safety features that distinguish modern SMR designs from earlier generations, Passive Containment Cooling Systems (PCCSs) occupy a central role. These systems rely on natural physical phenomena, such as steam condensation, to remove heat from the reactor containment without requiring external power or operator action. Strongly condensing environments exhibit unique characteristics that influence both heat transfer, particularly when non-condensable gases such as air are present in the containment atmosphere, and the transport of airborne radioactive contaminants, which might be released in the containment in the event of core degradation. This thesis investigates steam condensation in the presence of non-condensable gases in a set of experiments conducted at the Canadian Nuclear Laboratories (CNL), focusing on conditions representative of a severe accident scenario for a small integrated Pressurized Water Reactor (i-PWR). In this scenario, a Station Black Out (SBO) event triggers reactor shutdown, and the subsequent loss of secondary cooling leads to the venting of the Reactor Pressure Vessel (RPV). This releases steam into the containment environment, into which air infiltrates as a result of a prior loss of containment isolation event. Two distinct computational approaches are employed to simulate these experiments. The first is a high-fidelity Computational Fluid Dynamics (CFD) model developed in STAR-CCM+, which resolves the detailed flow field within the experimental vessel. The second is MELCOR, a lumped-parameter severe accident code that is widely used in nuclear safety analyses but operates at a considerably lower level of spatial resolution. By applying both tools to the same experimental reference, this study enables a direct and systematic comparison of their respective capabilities and limitations. Built on a diffusion-based approach to condensation modelling, the CFD model successfully reproduces the experimentally observed layered structure, characterized by a hot, steam-rich region in the upper part of the vessel and a cooler, air-dominated region below. The position of the interface between these two layers is captured with good accuracy. Steam condensation rates are slightly overestimated across all test cases, with deviations ranging from approximately 4\% to 27\%, while the turbulent flow structure is reproduced with sufficient fidelity to support future extensions of the model to include aerosol transport. A systematic underestimation of temperature in the lower air-rich layer is identified and primarily attributed to the absence of thermal radiation energy transfer between the two stratified layers. A dedicated sensitivity analysis of radiative heat transfer confirms that its inclusion partially mitigates this discrepancy and improves agreement with experimental observations. Additionally, the omission of condensate flow modelling might also contribute to this underestimation, as the present model neglects the thermal resistance associated with the liquid flow developed on the wall. The MELCOR analysis is conducted utilizing two modelling strategies of increasing spatial resolution. The first strategy represents the entire experimental vessel as a single control volume. This approach yields a systematic but acceptable overestimation of condensation rates (approximately 12\% to 40\%), and provides reasonable estimates of aerosol retention. However, the analysis reveals that this agreement is driven by error compensation rather than a physically accurate representation of the involved phenomena. The second MELCOR strategy subdivides the vessel into a finer (6x3) grid of control volumes, guided by the spatial distribution of flow patterns identified via the CFD analysis. This refined model proves unable of reliably reproducing the system behaviour. MELCOR's governing equations lack explicit multi-dimensional momentum conservation and do not embed the downward transport of the jet's momentum flux; as a result, steam remains artificially confined within the first layer of control volumes rather than penetrating to lower levels, leading to physically inconsistent flow patterns. This behaviour directly contradicts both experimental evidence and CFD predictions. The associated errors increase systematically with steam injection rate, limiting the model's applicability to safety-related analyses in its current form. The findings establish a validated CFD framework for strong condensation in binary steam-air mixtures under containment-relevant conditions, and characterize MELCOR's capabilities and limitations in simulating spatially sensitive phenomena in large open volumes. These results motivate further work on physically consistent extensions of the lumped-parameter approach, including jet momentum flux transport in MELCOR's momentum equation.

La transizione globale verso un settore energetico a zero emissioni di carbonio sta accelerando l’implementazione dell’energia nucleare e ha rinnovato l’interesse nei confronti degli Small Modular Reactors (SMR). Tra le caratteristiche di sicurezza che distinguono i moderni progetti di SMR dalle generazioni precedenti, i Sistemi di Raffreddamento Passivo del Contenimento (PCCS, Passive Containment Cooling Systems) rivestono un ruolo centrale. Questi sistemi si basano su fenomeni fisici naturali, come la condensazione del vapore, per rimuovere il calore dal contenimento del reattore senza richiedere alimentazione esterna o intervento dell’operatore. Gli ambienti con forte condensazione presentano caratteristiche uniche che influenzano sia il trasferimento di calore, in particolare quando sono presenti gas non condensabili come l’aria nell’atmosfera del contenimento, sia il trasporto di contaminanti radioattivi, che potrebbero essere rilasciati nel contenimento in caso di degradazione del nocciolo. Questa tesi indaga la condensazione del vapore in presenza di gas non condensabili in una serie di esperimenti condotti presso i Canadian Nuclear Laboratories (CNL), concentrandosi su condizioni rappresentative di uno scenario di incidente grave per un piccolo reattore ad acqua pressurizzata integrato (i-PWR). In questo scenario, un evento di Station Black Out (SBO) provoca lo spegnimento del reattore e la successiva perdita del raffreddamento secondario porta allo sfiato del Reactor Pressure Vessel (RPV), rilasciando vapore nell’ambiente del contenimento, dove l’aria si è infiltrata a seguito di una precedente breccia nel contenimento. Per simulare questi esperimenti vengono impiegati due approcci computazionali distinti. Il primo è un modello Computational Fluid Dynamics (CFD) sviluppato in STAR-CCM+, che risolve il campo di flusso all’interno dell'apparato sperimentale. Il secondo è MELCOR, un codice a parametri concentrati ampiamente utilizzato nelle analisi di sicurezza nucleare, ma che opera con una risoluzione spaziale notevolmente inferiore. Applicando entrambi gli strumenti allo stesso riferimento sperimentale, questo studio consente un confronto diretto e sistematico delle rispettive capacità e limitazioni. Basato su un approccio diffusivo per la modellazione della condensazione, il modello CFD riproduce con successo la stratificazione osservata sperimentalmente, caratterizzata da una regione superiore calda e ricca di vapore e da una regione inferiore più fredda dominata dall’aria. La posizione dell’interfaccia tra questi due strati viene replicata con buona accuratezza. I tassi di condensazione del vapore sono leggermente sovrastimati in tutti i casi investigati, con deviazioni che variano dal 4\% al 27\%, mentre la struttura del flusso turbolento viene riprodotta con fedeltà sufficiente a supportare future estensioni del modello per includere il trasporto di aerosol. Il modello sottostima sistematicamente la temperatura nello strato inferiore, principalmente a causa dell’assenza dello scambio termico radiativo tra i due strati. Un’analisi dedicata al trasferimento di calore radiativo conferma che la sua inclusione mitiga parzialmente questa discrepanza e migliora l’accordo con le osservazioni sperimentali. Inoltre, l'omissione della modellazione del flusso di condensato potrebbe contribuire a questa sottostima, poiché il presentemodello trascura la resistenza termica associata al flusso liquido che si sviluppa sulla parete. L’analisi MELCOR viene condotta utilizzando due strategie di modellazione con diversa risoluzione spaziale. La prima strategia rappresenta l’intero recipiente sperimentale come un unico volume di controllo. Questo approccio produce una sovrastima sistematica ma accettabile dei tassi di condensazione (circa dal 12\% al 40\%) e fornisce stime ragionevoli della ritenzione degli aerosol. Tuttavia, l’analisi rivela che questo accordo è guidato da errori compensativi piuttosto che da una rappresentazione fisicamente accurata dei fenomeni coinvolti. La seconda strategia MELCOR suddivide il recipiente in una griglia più fine (6x3) di volumi di controllo, guidata dalla configurazione spaziale del flusso identificata tramite l’analisi CFD. Questo modello si rivela incapace di riprodurre in modo affidabile il comportamento del sistema. Le equazioni caratteristiche di MELCOR non prevedono una conservazione esplicita multidimensionale della quantità di moto, e non incorporano il trasporto verso il basso del flusso di quantità di moto del getto; di conseguenza, il vapore rimane artificialmente confinato all'interno del primo strato di volumi di controllo anziché penetrare verso i livelli inferiori, generando pattern di flusso fisicamente incoerenti. Questo comportamento contraddice direttamente sia le evidenze sperimentali sia le previsioni CFD. Gli errori associati aumentano sistematicamente con il tasso di iniezione del vapore, limitando l'applicabilità del modello alle analisi di sicurezza nella sua forma attuale. I risultati stabiliscono un framework CFD validato per la condensazione in miscele binarie vapore-aria in condizioni rilevanti per il contenimento. Inoltre, caratterizzano le capacità e i limiti di MELCOR nella simulazione di fenomeni sensibili alla distribuzione spaziale in grandi volumi. Questi risultati motivano ulteriori studi su estensioni fisicamente coerenti dell’approccio a parametri concentrati, includendo il trasporto della quantità di moto del getto nell'equazione del momento di MELCOR.

Multi-scale investigation of steam condensation in presence of non-condensable gases for passive containment cooling in small Modular Reactors

Ronchi, Riccardo
2025/2026

Abstract

The global transition toward a carbon-neutral energy sector is accelerating the deployment of nuclear power and has renewed the interest in Small Modular Reactors (SMRs). Among the safety features that distinguish modern SMR designs from earlier generations, Passive Containment Cooling Systems (PCCSs) occupy a central role. These systems rely on natural physical phenomena, such as steam condensation, to remove heat from the reactor containment without requiring external power or operator action. Strongly condensing environments exhibit unique characteristics that influence both heat transfer, particularly when non-condensable gases such as air are present in the containment atmosphere, and the transport of airborne radioactive contaminants, which might be released in the containment in the event of core degradation. This thesis investigates steam condensation in the presence of non-condensable gases in a set of experiments conducted at the Canadian Nuclear Laboratories (CNL), focusing on conditions representative of a severe accident scenario for a small integrated Pressurized Water Reactor (i-PWR). In this scenario, a Station Black Out (SBO) event triggers reactor shutdown, and the subsequent loss of secondary cooling leads to the venting of the Reactor Pressure Vessel (RPV). This releases steam into the containment environment, into which air infiltrates as a result of a prior loss of containment isolation event. Two distinct computational approaches are employed to simulate these experiments. The first is a high-fidelity Computational Fluid Dynamics (CFD) model developed in STAR-CCM+, which resolves the detailed flow field within the experimental vessel. The second is MELCOR, a lumped-parameter severe accident code that is widely used in nuclear safety analyses but operates at a considerably lower level of spatial resolution. By applying both tools to the same experimental reference, this study enables a direct and systematic comparison of their respective capabilities and limitations. Built on a diffusion-based approach to condensation modelling, the CFD model successfully reproduces the experimentally observed layered structure, characterized by a hot, steam-rich region in the upper part of the vessel and a cooler, air-dominated region below. The position of the interface between these two layers is captured with good accuracy. Steam condensation rates are slightly overestimated across all test cases, with deviations ranging from approximately 4\% to 27\%, while the turbulent flow structure is reproduced with sufficient fidelity to support future extensions of the model to include aerosol transport. A systematic underestimation of temperature in the lower air-rich layer is identified and primarily attributed to the absence of thermal radiation energy transfer between the two stratified layers. A dedicated sensitivity analysis of radiative heat transfer confirms that its inclusion partially mitigates this discrepancy and improves agreement with experimental observations. Additionally, the omission of condensate flow modelling might also contribute to this underestimation, as the present model neglects the thermal resistance associated with the liquid flow developed on the wall. The MELCOR analysis is conducted utilizing two modelling strategies of increasing spatial resolution. The first strategy represents the entire experimental vessel as a single control volume. This approach yields a systematic but acceptable overestimation of condensation rates (approximately 12\% to 40\%), and provides reasonable estimates of aerosol retention. However, the analysis reveals that this agreement is driven by error compensation rather than a physically accurate representation of the involved phenomena. The second MELCOR strategy subdivides the vessel into a finer (6x3) grid of control volumes, guided by the spatial distribution of flow patterns identified via the CFD analysis. This refined model proves unable of reliably reproducing the system behaviour. MELCOR's governing equations lack explicit multi-dimensional momentum conservation and do not embed the downward transport of the jet's momentum flux; as a result, steam remains artificially confined within the first layer of control volumes rather than penetrating to lower levels, leading to physically inconsistent flow patterns. This behaviour directly contradicts both experimental evidence and CFD predictions. The associated errors increase systematically with steam injection rate, limiting the model's applicability to safety-related analyses in its current form. The findings establish a validated CFD framework for strong condensation in binary steam-air mixtures under containment-relevant conditions, and characterize MELCOR's capabilities and limitations in simulating spatially sensitive phenomena in large open volumes. These results motivate further work on physically consistent extensions of the lumped-parameter approach, including jet momentum flux transport in MELCOR's momentum equation.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
La transizione globale verso un settore energetico a zero emissioni di carbonio sta accelerando l’implementazione dell’energia nucleare e ha rinnovato l’interesse nei confronti degli Small Modular Reactors (SMR). Tra le caratteristiche di sicurezza che distinguono i moderni progetti di SMR dalle generazioni precedenti, i Sistemi di Raffreddamento Passivo del Contenimento (PCCS, Passive Containment Cooling Systems) rivestono un ruolo centrale. Questi sistemi si basano su fenomeni fisici naturali, come la condensazione del vapore, per rimuovere il calore dal contenimento del reattore senza richiedere alimentazione esterna o intervento dell’operatore. Gli ambienti con forte condensazione presentano caratteristiche uniche che influenzano sia il trasferimento di calore, in particolare quando sono presenti gas non condensabili come l’aria nell’atmosfera del contenimento, sia il trasporto di contaminanti radioattivi, che potrebbero essere rilasciati nel contenimento in caso di degradazione del nocciolo. Questa tesi indaga la condensazione del vapore in presenza di gas non condensabili in una serie di esperimenti condotti presso i Canadian Nuclear Laboratories (CNL), concentrandosi su condizioni rappresentative di uno scenario di incidente grave per un piccolo reattore ad acqua pressurizzata integrato (i-PWR). In questo scenario, un evento di Station Black Out (SBO) provoca lo spegnimento del reattore e la successiva perdita del raffreddamento secondario porta allo sfiato del Reactor Pressure Vessel (RPV), rilasciando vapore nell’ambiente del contenimento, dove l’aria si è infiltrata a seguito di una precedente breccia nel contenimento. Per simulare questi esperimenti vengono impiegati due approcci computazionali distinti. Il primo è un modello Computational Fluid Dynamics (CFD) sviluppato in STAR-CCM+, che risolve il campo di flusso all’interno dell'apparato sperimentale. Il secondo è MELCOR, un codice a parametri concentrati ampiamente utilizzato nelle analisi di sicurezza nucleare, ma che opera con una risoluzione spaziale notevolmente inferiore. Applicando entrambi gli strumenti allo stesso riferimento sperimentale, questo studio consente un confronto diretto e sistematico delle rispettive capacità e limitazioni. Basato su un approccio diffusivo per la modellazione della condensazione, il modello CFD riproduce con successo la stratificazione osservata sperimentalmente, caratterizzata da una regione superiore calda e ricca di vapore e da una regione inferiore più fredda dominata dall’aria. La posizione dell’interfaccia tra questi due strati viene replicata con buona accuratezza. I tassi di condensazione del vapore sono leggermente sovrastimati in tutti i casi investigati, con deviazioni che variano dal 4\% al 27\%, mentre la struttura del flusso turbolento viene riprodotta con fedeltà sufficiente a supportare future estensioni del modello per includere il trasporto di aerosol. Il modello sottostima sistematicamente la temperatura nello strato inferiore, principalmente a causa dell’assenza dello scambio termico radiativo tra i due strati. Un’analisi dedicata al trasferimento di calore radiativo conferma che la sua inclusione mitiga parzialmente questa discrepanza e migliora l’accordo con le osservazioni sperimentali. Inoltre, l'omissione della modellazione del flusso di condensato potrebbe contribuire a questa sottostima, poiché il presentemodello trascura la resistenza termica associata al flusso liquido che si sviluppa sulla parete. L’analisi MELCOR viene condotta utilizzando due strategie di modellazione con diversa risoluzione spaziale. La prima strategia rappresenta l’intero recipiente sperimentale come un unico volume di controllo. Questo approccio produce una sovrastima sistematica ma accettabile dei tassi di condensazione (circa dal 12\% al 40\%) e fornisce stime ragionevoli della ritenzione degli aerosol. Tuttavia, l’analisi rivela che questo accordo è guidato da errori compensativi piuttosto che da una rappresentazione fisicamente accurata dei fenomeni coinvolti. La seconda strategia MELCOR suddivide il recipiente in una griglia più fine (6x3) di volumi di controllo, guidata dalla configurazione spaziale del flusso identificata tramite l’analisi CFD. Questo modello si rivela incapace di riprodurre in modo affidabile il comportamento del sistema. Le equazioni caratteristiche di MELCOR non prevedono una conservazione esplicita multidimensionale della quantità di moto, e non incorporano il trasporto verso il basso del flusso di quantità di moto del getto; di conseguenza, il vapore rimane artificialmente confinato all'interno del primo strato di volumi di controllo anziché penetrare verso i livelli inferiori, generando pattern di flusso fisicamente incoerenti. Questo comportamento contraddice direttamente sia le evidenze sperimentali sia le previsioni CFD. Gli errori associati aumentano sistematicamente con il tasso di iniezione del vapore, limitando l'applicabilità del modello alle analisi di sicurezza nella sua forma attuale. I risultati stabiliscono un framework CFD validato per la condensazione in miscele binarie vapore-aria in condizioni rilevanti per il contenimento. Inoltre, caratterizzano le capacità e i limiti di MELCOR nella simulazione di fenomeni sensibili alla distribuzione spaziale in grandi volumi. Questi risultati motivano ulteriori studi su estensioni fisicamente coerenti dell’approccio a parametri concentrati, includendo il trasporto della quantità di moto del getto nell'equazione del momento di MELCOR.
File allegati
File Dimensione Formato  
Riccardo Ronchi_Executive Summary.pdf

accessibile in internet per tutti

Descrizione: Executive Summary
Dimensione 909.02 kB
Formato Adobe PDF
909.02 kB Adobe PDF Visualizza/Apri
Riccardo Ronchi_Thesis.pdf

accessibile in internet per tutti

Descrizione: Thesis Manuscript
Dimensione 17.43 MB
Formato Adobe PDF
17.43 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261434