This thesis investigates the mechanical behavior and fracture-related response of human trabecular bone from femoral head specimens belonging to healthy, osteoporotic, and post-Covid-19 patients within the framework of the GAP project. The study had two main objectives: to characterize the relationship between bone volume fraction (BV/TV) and apparent Young’s modulus, and to evaluate an empirical stress intensity factor formulation for cracks identified through synchrotron imaging. High-resolution synchrotron radiation micro-computed tomography was used to reconstruct trabecular sub-volumes, which were segmented and converted into finite element models for quasi-static compression simulations. A total of 11 sub-volumes were analyzed (4 healthy, 3 osteoporotic, and 4 post-Covid-19). Apparent Young’s modulus ranged from 76.1 to 2323.7 MPa in the healthy group, from 45.4 to 1462.4 MPa in the osteoporotic group, and from 6.7 to 1878.8 MPa in the post-Covid-19 group. Power-law regression confirmed a nonlinear relationship between BV/TV and apparent stiffness. The healthy, osteoporotic, and post- Covid-19groups yielded exponents of 3.50, 2.88, and 3.86, respectively, while the combined regression produced C = 7060.1, n = 2.56, and R2 = 0.61, indicating that BV/TV is a relevant predictor of apparent stiffness although additional microarchitectural features also influence the mechanical response. In the second part of the study, crack length, crack mouth opening displacement, and the estimated apparent Young’s modulus were used to calculate apparent stress intensity factors. The obtained values (0.020–0.424 MPa√m) provided plausible comparative fracture-related indicators at the trabecular scale. Although the adopted formulation is based on linear elastic and isotropic assumptions, the results suggest that it can be used as a preliminary tool to compare crack-related mechanical conditions among different pathological groups. Overall, this work highlights the influence of bone microarchitecture on both elastic and fracture-related behavior and provides a basis for future validation using larger datasets and more advanced fracture mechanics models.

Questa tesi analizza il comportamento meccanico e la risposta a frattura dell’osso trabecolare umano proveniente da teste femorali di pazienti sani, osteoporotici e post-Covid-19, nell’ambito del progetto GAP. Lo studio ha avuto due obiettivi principali: caratterizzare la relazione tra la frazione di volume osseo (BV/TV) e il modulo di Young apparente e valutare l’applicabilità di una formulazione empirica del fattore di intensità degli sforzi a cricche identificate mediante imaging sincrotronico. La microtomografia computerizzata ad alta risoluzione con radiazione di sincrotrone è stata utilizzata per ricostruire sottovolumi tridimensionali di osso trabecolare, successivamente segmentati e convertiti in modelli agli elementi finiti per simulazioni di compressione quasi statica. Sono stati analizzati 11 sottovolumi (4 sani, 3 osteoporotici e 4 post-Covid-19). Il modulo di Young apparente è risultato compreso tra 76,1 e 2323,7 MPa nel gruppo sano, tra 45,4 e 1462,4 MPa nel gruppo osteoporotico e tra 6,7 e 1878,8 MPa nel gruppo post-Covid-19. Le regressioni secondo una legge di potenza hanno confermato una relazione non lineare tra BV/TV e rigidezza apparente. I gruppi sano, osteoporotico e post-Covid-19 hanno mostrato esponenti pari rispettivamente a 3,50, 2,88 e 3,86, mentre la regressione complessiva ha fornito C = 7060,1, n = 2,56 e R2 = 0,61, indicando che il BV/TV rappresenta un buon predittore della rigidezza apparente, sebbene anche altre caratteristiche microstrutturali influenzino la risposta meccanica. Nella seconda parte dello studio, la lunghezza della cricca, il crack mouth opening displacement (COD) e il modulo di Young apparente stimato localmente sono stati utilizzati per calcolare il fattore di intensità degli sforzi apparente. I valori ottenuti (0,020–0,424 MPa√m) hanno fornito indicatori comparativi plausibili della risposta a frattura alla scala trabecolare. Sebbene la formulazione adottata si basi sulle ipotesi di elasticità lineare e isotropia, i risultati suggeriscono che possa rappresentare uno strumento preliminare per confrontare le condizioni meccaniche associate alle cricche tra diversi gruppi patologici. Nel complesso, questo lavoro evidenzia l’influenza della microarchitettura ossea sul comportamento elastico e a frattura dell’osso trabecolare e fornisce una base per future validazioni su dataset più ampi e mediante modelli di meccanica della frattura più avanzati.

Stiffness and fracture analysis of femoral head trabecular bone using synchrotron imaging and FE analysis

BERTOLASO, GIACOMO
2025/2026

Abstract

This thesis investigates the mechanical behavior and fracture-related response of human trabecular bone from femoral head specimens belonging to healthy, osteoporotic, and post-Covid-19 patients within the framework of the GAP project. The study had two main objectives: to characterize the relationship between bone volume fraction (BV/TV) and apparent Young’s modulus, and to evaluate an empirical stress intensity factor formulation for cracks identified through synchrotron imaging. High-resolution synchrotron radiation micro-computed tomography was used to reconstruct trabecular sub-volumes, which were segmented and converted into finite element models for quasi-static compression simulations. A total of 11 sub-volumes were analyzed (4 healthy, 3 osteoporotic, and 4 post-Covid-19). Apparent Young’s modulus ranged from 76.1 to 2323.7 MPa in the healthy group, from 45.4 to 1462.4 MPa in the osteoporotic group, and from 6.7 to 1878.8 MPa in the post-Covid-19 group. Power-law regression confirmed a nonlinear relationship between BV/TV and apparent stiffness. The healthy, osteoporotic, and post- Covid-19groups yielded exponents of 3.50, 2.88, and 3.86, respectively, while the combined regression produced C = 7060.1, n = 2.56, and R2 = 0.61, indicating that BV/TV is a relevant predictor of apparent stiffness although additional microarchitectural features also influence the mechanical response. In the second part of the study, crack length, crack mouth opening displacement, and the estimated apparent Young’s modulus were used to calculate apparent stress intensity factors. The obtained values (0.020–0.424 MPa√m) provided plausible comparative fracture-related indicators at the trabecular scale. Although the adopted formulation is based on linear elastic and isotropic assumptions, the results suggest that it can be used as a preliminary tool to compare crack-related mechanical conditions among different pathological groups. Overall, this work highlights the influence of bone microarchitecture on both elastic and fracture-related behavior and provides a basis for future validation using larger datasets and more advanced fracture mechanics models.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
Questa tesi analizza il comportamento meccanico e la risposta a frattura dell’osso trabecolare umano proveniente da teste femorali di pazienti sani, osteoporotici e post-Covid-19, nell’ambito del progetto GAP. Lo studio ha avuto due obiettivi principali: caratterizzare la relazione tra la frazione di volume osseo (BV/TV) e il modulo di Young apparente e valutare l’applicabilità di una formulazione empirica del fattore di intensità degli sforzi a cricche identificate mediante imaging sincrotronico. La microtomografia computerizzata ad alta risoluzione con radiazione di sincrotrone è stata utilizzata per ricostruire sottovolumi tridimensionali di osso trabecolare, successivamente segmentati e convertiti in modelli agli elementi finiti per simulazioni di compressione quasi statica. Sono stati analizzati 11 sottovolumi (4 sani, 3 osteoporotici e 4 post-Covid-19). Il modulo di Young apparente è risultato compreso tra 76,1 e 2323,7 MPa nel gruppo sano, tra 45,4 e 1462,4 MPa nel gruppo osteoporotico e tra 6,7 e 1878,8 MPa nel gruppo post-Covid-19. Le regressioni secondo una legge di potenza hanno confermato una relazione non lineare tra BV/TV e rigidezza apparente. I gruppi sano, osteoporotico e post-Covid-19 hanno mostrato esponenti pari rispettivamente a 3,50, 2,88 e 3,86, mentre la regressione complessiva ha fornito C = 7060,1, n = 2,56 e R2 = 0,61, indicando che il BV/TV rappresenta un buon predittore della rigidezza apparente, sebbene anche altre caratteristiche microstrutturali influenzino la risposta meccanica. Nella seconda parte dello studio, la lunghezza della cricca, il crack mouth opening displacement (COD) e il modulo di Young apparente stimato localmente sono stati utilizzati per calcolare il fattore di intensità degli sforzi apparente. I valori ottenuti (0,020–0,424 MPa√m) hanno fornito indicatori comparativi plausibili della risposta a frattura alla scala trabecolare. Sebbene la formulazione adottata si basi sulle ipotesi di elasticità lineare e isotropia, i risultati suggeriscono che possa rappresentare uno strumento preliminare per confrontare le condizioni meccaniche associate alle cricche tra diversi gruppi patologici. Nel complesso, questo lavoro evidenzia l’influenza della microarchitettura ossea sul comportamento elastico e a frattura dell’osso trabecolare e fornisce una base per future validazioni su dataset più ampi e mediante modelli di meccanica della frattura più avanzati.
File allegati
File Dimensione Formato  
2026_07_Bertolaso_executive summary.pdf

accessibile in internet per tutti

Descrizione: executive summary
Dimensione 6.3 MB
Formato Adobe PDF
6.3 MB Adobe PDF Visualizza/Apri
2026_07_Bertolaso.pdf

accessibile in internet per tutti

Descrizione: testo tesi
Dimensione 49.28 MB
Formato Adobe PDF
49.28 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261506