Green ammonia production offers a promising route to decarbonize hydrogen-intensive chemical processes by replacing fossil-based hydrogen with hydrogen produced through renewable-powered water electrolysis. However, when ammonia is produced in a fully islanded configuration, the intermittent and non-dispatchable nature of renewable power introduces a major operational challenge: the plant must coordinate electrolysis, battery storage, hydrogen storage, and Haber-Bosch synthesis while respecting process constraints and maintaining production over long operating periods. This thesis investigates the closed-loop operation of a fixed islanded green ammonia plant powered by combined solar and wind generation. The reference plant design derives from a prior sustainability-oriented design framework. The focus is therefore shifted from plant sizing to plant operation. A supervisory model predictive control strategy is developed to schedule the plant over annual renewable power profiles using a 24-hour receding prediction horizon. The main methodological contribution is a reduced-degree-of-freedom MPC formulation. Instead of optimizing the electrolyzer power and the Haber-Bosch load as independent decision variables, the controller manipulates only two variables: the battery power, β, and the hydrogen storage flow, γ. The electrolyzer power and the aggregate electrical demand of the ammonia-production section are then determined implicitly through the plant-level electrical and material balances and the associated saturation logic. This structure embeds the intended operating rationale of the islanded plant while keeping the optimization problem compact. The controller is tested on two annual case studies based on processed CAISO 2023 and 2024 renewable profiles. The results show that the proposed MPC strategy maintains feasible operation over the full simulated horizons and achieves annual ammonia productions of 38,139.3 tNH₃ and 38,727.9 tNH₃, respectively, exceeding the nominal reference target of 36,500 tNH₃/y. Curtailment remains significant, mainly because the installed renewable capacity can exceed the maximum instantaneous absorption capability of the electrolyzer, Haber-Bosch section, and battery. The MPC results are also compared with a feasible reactive human-like operator that does not use forecast information. The predictive controller achieves higher production and lower curtailment in both years, confirming the value of anticipative coordination of electrical and material storage. Overall, the thesis demonstrates that a compact two-degree-of-freedom MPC can effectively supervise the operation of an islanded green ammonia plant under variable renewable power supply.

La produzione di ammoniaca verde rappresenta una possibile via per decarbonizzare processi chimici ad alta intensità di idrogeno, sostituendo l’idrogeno di origine fossile con idrogeno prodotto tramite elettrolisi dell’acqua alimentata da energia rinnovabile. Tuttavia, quando la produzione avviene in una configurazione completamente isolata dalla rete, la natura intermittente e non programmabile delle fonti rinnovabili introduce una rilevante complessità operativa: l’impianto deve coordinare elettrolisi, accumulo elettrico, accumulo di idrogeno e sintesi Haber-Bosch rispettando i vincoli di processo e mantenendo la produzione su lunghi orizzonti temporali. Questa tesi studia l’operazione ad anello chiuso di un impianto di ammoniaca verde isolato dalla rete e alimentato da energia solare ed eolica. Il dimensionamento dell’impianto deriva da una progettazione precedente volta a ottimizzarne la sostenibilità. Il lavoro sposta quindi l’attenzione dal dimensionamento dell’impianto alla sua gestione operativa. A questo scopo, viene sviluppata una strategia di controllo predittivo basata su un modello a livello supervisivo, utilizzata per programmare l’impianto su profili annuali di potenza rinnovabile mediante un orizzonte predittivo mobile di 24 ore. Il principale contributo metodologico è una formulazione MPC a ridotto numero di gradi di libertà. Invece di ottimizzare direttamente la potenza dell’elettrolizzatore e il carico Haber-Bosch come variabili decisionali indipendenti, il controllore manipola solo due variabili: la potenza della batteria, β, e il flusso netto da/verso l’accumulo di idrogeno, γ. La potenza dell’elettrolizzatore e il fabbisogno elettrico aggregato della sezione di produzione dell’ammoniaca sono quindi determinati implicitamente attraverso i bilanci elettrici e materiali dell’impianto e la relativa logica di saturazione. Questa struttura incorpora la logica operativa desiderata per l’impianto isolato dalla rete, mantenendo al tempo stesso compatto il problema di ottimizzazione. Il controllore viene testato su due casi studio annuali basati su profili rinnovabili CAISO 2023 e 2024 opportunamente elaborati. I risultati mostrano che la strategia MPC proposta mantiene un’operazione ammissibile lungo gli orizzonti simulati e raggiunge produzioni annuali di ammoniaca pari a 38,139.3 tNH₃ e 38,727.9 tNH₃, superando l’obiettivo nominale di riferimento di 36,500 tNH₃/y. Il taglio della produzione rinnovabile rimane significativo, principalmente perché la capacità rinnovabile installata può eccedere la massima capacità istantanea di assorbimento dell’elettrolizzatore, della sezione Haber-Bosch e della batteria. I risultati MPC sono inoltre confrontati con un operatore reattivo di tipo umano, ammissibile ma non predittivo, che non utilizza informazioni previsionali. Il controllore predittivo ottiene una produzione maggiore e un minore taglio della produzione rinnovabile in entrambi gli anni, confermando il valore della coordinazione anticipativa dell’accumulo elettrico e materiale. Nel complesso, la tesi dimostra che un MPC compatto a due gradi di libertà può supervisionare efficacemente l’operazione di un impianto di ammoniaca verde isolato dalla rete e soggetto a disponibilità rinnovabile variabile.

Storage-driven model predictive control for islanded green ammonia plant operation

Colosi, Matteo
2025/2026

Abstract

Green ammonia production offers a promising route to decarbonize hydrogen-intensive chemical processes by replacing fossil-based hydrogen with hydrogen produced through renewable-powered water electrolysis. However, when ammonia is produced in a fully islanded configuration, the intermittent and non-dispatchable nature of renewable power introduces a major operational challenge: the plant must coordinate electrolysis, battery storage, hydrogen storage, and Haber-Bosch synthesis while respecting process constraints and maintaining production over long operating periods. This thesis investigates the closed-loop operation of a fixed islanded green ammonia plant powered by combined solar and wind generation. The reference plant design derives from a prior sustainability-oriented design framework. The focus is therefore shifted from plant sizing to plant operation. A supervisory model predictive control strategy is developed to schedule the plant over annual renewable power profiles using a 24-hour receding prediction horizon. The main methodological contribution is a reduced-degree-of-freedom MPC formulation. Instead of optimizing the electrolyzer power and the Haber-Bosch load as independent decision variables, the controller manipulates only two variables: the battery power, β, and the hydrogen storage flow, γ. The electrolyzer power and the aggregate electrical demand of the ammonia-production section are then determined implicitly through the plant-level electrical and material balances and the associated saturation logic. This structure embeds the intended operating rationale of the islanded plant while keeping the optimization problem compact. The controller is tested on two annual case studies based on processed CAISO 2023 and 2024 renewable profiles. The results show that the proposed MPC strategy maintains feasible operation over the full simulated horizons and achieves annual ammonia productions of 38,139.3 tNH₃ and 38,727.9 tNH₃, respectively, exceeding the nominal reference target of 36,500 tNH₃/y. Curtailment remains significant, mainly because the installed renewable capacity can exceed the maximum instantaneous absorption capability of the electrolyzer, Haber-Bosch section, and battery. The MPC results are also compared with a feasible reactive human-like operator that does not use forecast information. The predictive controller achieves higher production and lower curtailment in both years, confirming the value of anticipative coordination of electrical and material storage. Overall, the thesis demonstrates that a compact two-degree-of-freedom MPC can effectively supervise the operation of an islanded green ammonia plant under variable renewable power supply.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
La produzione di ammoniaca verde rappresenta una possibile via per decarbonizzare processi chimici ad alta intensità di idrogeno, sostituendo l’idrogeno di origine fossile con idrogeno prodotto tramite elettrolisi dell’acqua alimentata da energia rinnovabile. Tuttavia, quando la produzione avviene in una configurazione completamente isolata dalla rete, la natura intermittente e non programmabile delle fonti rinnovabili introduce una rilevante complessità operativa: l’impianto deve coordinare elettrolisi, accumulo elettrico, accumulo di idrogeno e sintesi Haber-Bosch rispettando i vincoli di processo e mantenendo la produzione su lunghi orizzonti temporali. Questa tesi studia l’operazione ad anello chiuso di un impianto di ammoniaca verde isolato dalla rete e alimentato da energia solare ed eolica. Il dimensionamento dell’impianto deriva da una progettazione precedente volta a ottimizzarne la sostenibilità. Il lavoro sposta quindi l’attenzione dal dimensionamento dell’impianto alla sua gestione operativa. A questo scopo, viene sviluppata una strategia di controllo predittivo basata su un modello a livello supervisivo, utilizzata per programmare l’impianto su profili annuali di potenza rinnovabile mediante un orizzonte predittivo mobile di 24 ore. Il principale contributo metodologico è una formulazione MPC a ridotto numero di gradi di libertà. Invece di ottimizzare direttamente la potenza dell’elettrolizzatore e il carico Haber-Bosch come variabili decisionali indipendenti, il controllore manipola solo due variabili: la potenza della batteria, β, e il flusso netto da/verso l’accumulo di idrogeno, γ. La potenza dell’elettrolizzatore e il fabbisogno elettrico aggregato della sezione di produzione dell’ammoniaca sono quindi determinati implicitamente attraverso i bilanci elettrici e materiali dell’impianto e la relativa logica di saturazione. Questa struttura incorpora la logica operativa desiderata per l’impianto isolato dalla rete, mantenendo al tempo stesso compatto il problema di ottimizzazione. Il controllore viene testato su due casi studio annuali basati su profili rinnovabili CAISO 2023 e 2024 opportunamente elaborati. I risultati mostrano che la strategia MPC proposta mantiene un’operazione ammissibile lungo gli orizzonti simulati e raggiunge produzioni annuali di ammoniaca pari a 38,139.3 tNH₃ e 38,727.9 tNH₃, superando l’obiettivo nominale di riferimento di 36,500 tNH₃/y. Il taglio della produzione rinnovabile rimane significativo, principalmente perché la capacità rinnovabile installata può eccedere la massima capacità istantanea di assorbimento dell’elettrolizzatore, della sezione Haber-Bosch e della batteria. I risultati MPC sono inoltre confrontati con un operatore reattivo di tipo umano, ammissibile ma non predittivo, che non utilizza informazioni previsionali. Il controllore predittivo ottiene una produzione maggiore e un minore taglio della produzione rinnovabile in entrambi gli anni, confermando il valore della coordinazione anticipativa dell’accumulo elettrico e materiale. Nel complesso, la tesi dimostra che un MPC compatto a due gradi di libertà può supervisionare efficacemente l’operazione di un impianto di ammoniaca verde isolato dalla rete e soggetto a disponibilità rinnovabile variabile.
File allegati
File Dimensione Formato  
2026_07_Colosi_Executive_Summary.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Executive Summary
Dimensione 663.2 kB
Formato Adobe PDF
663.2 kB Adobe PDF   Visualizza/Apri
2026_07_Colosi_Thesis.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Thesis
Dimensione 3.71 MB
Formato Adobe PDF
3.71 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261523