Synthetic porous scaffolds constituted by periodic microstructures are widely studied for bone tissue engineering. This thesis proposes a topology optimization framework to design the microscopic unit cells composing these scaffolds using an inverse homogenization approach that targets the mechanical and fluid behavior of trabecular bone. The framework combines a multiphysics optimization algorithm, robust to manufacturing tolerances, with a local volume constraint that governs the material distribution within the unit cell and thereby tunes its porosity. Through the interplay of optimization steps and anisotropic mesh adaptation, the algorithm identifies four 3D unit cells, each maximizing either the homogenized bulk modulus or the homogenized permeability. Every candidate cell is scaled to a physical edge length that brings its pore distribution within the osteogenic window, and the rescaled cells are finally verified as a finite lattice via uniaxial compression tests in Abaqus and Lattice Boltzmann interstitial flow simulations. The resulting designs successfully distribute over 96% of their pore volume within the osteogenic window and exhibit stiffness and permeability consistent with those of human trabecular bone.
Gli scaffold sintetici costituiti da microstrutture periodiche sono ampiamente studiati nell'ingegneria tissutale ossea. Questa tesi propone un framework di ottimizzazione topologica per la progettazione delle celle unitarie microscopiche che compongono tali scaffold, attraverso un approccio di omogeneizzazione inversa che mira a replicare il comportamento meccanico e fluidodinamico dell'osso trabecolare. Il framework combina un algoritmo di ottimizzazione multifisica, robusto alle tolleranze di fabbricazione, con un vincolo di volume locale che regola la distribuzione del materiale all'interno della cella unitaria, controllandone così la porosità. Attraverso l'alternanza di passi di ottimizzazione e di adattazione anisotropa della mesh, l'algoritmo identifica quattro celle unitarie tridimensionali, ciascuna delle quali massimizza il modulo di compressione omogenizzato o la permeabilità omogenizzata. Ogni cella candidata è ridimensionata tramite la lunghezza fisica del lato in modo da portare la distribuzione dei pori all'interno dell'intervallo osteogenico, e le celle ridimensionate sono infine verificate, come struttura reticolare finita, tramite test di compressione uniassiale in Abaqus e simulazioni di flusso interstiziale con il metodo Lattice Boltzmann. I design risultanti distribuiscono oltre il 96% del volume dei pori all'interno dell'intervallo osteogenico ed esibiscono rigidezza e permeabilità coerenti con quelle dell'osso trabecolare umano.
Design of synthetic bone scaffolds through inverse homogenization topology optimization with local volume constraints
Baschiera, Damiano
2025/2026
Abstract
Synthetic porous scaffolds constituted by periodic microstructures are widely studied for bone tissue engineering. This thesis proposes a topology optimization framework to design the microscopic unit cells composing these scaffolds using an inverse homogenization approach that targets the mechanical and fluid behavior of trabecular bone. The framework combines a multiphysics optimization algorithm, robust to manufacturing tolerances, with a local volume constraint that governs the material distribution within the unit cell and thereby tunes its porosity. Through the interplay of optimization steps and anisotropic mesh adaptation, the algorithm identifies four 3D unit cells, each maximizing either the homogenized bulk modulus or the homogenized permeability. Every candidate cell is scaled to a physical edge length that brings its pore distribution within the osteogenic window, and the rescaled cells are finally verified as a finite lattice via uniaxial compression tests in Abaqus and Lattice Boltzmann interstitial flow simulations. The resulting designs successfully distribute over 96% of their pore volume within the osteogenic window and exhibit stiffness and permeability consistent with those of human trabecular bone.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_07_Baschiera_Tesi.pdf
non accessibile
Descrizione: Tesi
Dimensione
75.3 MB
Formato
Adobe PDF
|
75.3 MB | Adobe PDF | Visualizza/Apri |
|
2026_07_Baschiera_Executive Summary.pdf
non accessibile
Descrizione: Executive Summary
Dimensione
20.58 MB
Formato
Adobe PDF
|
20.58 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/261539