In high-complexity healthcare facilities such as the Papa Giovanni XXIII hospital in Bergamo, the management of medical devices requires a strong effort, especially for the analysis of maintenance records. In CMMS (Computerized Maintenance Management System), the description of a failure or a repair is written in natural language, very often through abbreviations, acronyms, or jargon terms that hinder the aggregate analysis of the request, slowing down process automation. The present thesis work proposes a dashboard to support the decision-making activities of the SC Clinical Engineering based on a three-layer cascaded multi-task architecture: deterministic lexical rules (first layer), semantic prototypes obtained from dense vector representations generated by the multilingual-e5-small transformer (second layer), and, finally, a weighted ensemble on four supervised Machine Learning models (third layer), all to predict the results of the six tasks (Problem, Resolution, Spare, Spare quantity, Spare codes). From the experimental evaluation, an accuracy of 59.3% emerges for the Problem task, 67.0% for Resolution, and 57.6% for Spare, reaching 97.3% accuracy for lower dimensionality tasks. The investigation of the geometric space brought to light several limitations, including a 1-NN purity of 40.4% and isolation rates up to 85%, associated with resolution attempts through the ablation of the transformer model's capacity using the base version of the same. All this leads to the demonstration that the real bottleneck lies in the structural noise intrinsic to the input data, and not in the algorithmic capabilities, prospectively offering a useful workspace for data cleaning and for the integration of the work into hospital workflows.

In strutture sanitarie ad alta complessità come l’ospedale Papa Giovanni XXIII di Bergamo la gestione dei dispositivi medici richiede un forte impegno, in particolare per l’analisi dei registri manutentivi. Nei CMMS (Computerized Maintenance Management System) la descrizione di un guasto o di una riparazione è redatta in linguaggio naturale, molto spesso attraverso sigle, acronimi o termini gergali che ostacolano l’analisi aggregata della richiesta, rallentando l’automazione del processo. Il lavoro di tesi presente propone una dashboard di supporto alle attività di decision making della SC Ingegneria Clinica che si fonda su di un’architettura multi-task a cascata su tre layer: regole deterministiche lessicali (primo layer) prototipi semantici ottenuti da rappresentazioni vettoriali dense generate dal transformer multilingual-e5 small (secondo layer) e, infine, un ensemble pesato su quattro modelli di Machine Learning supervisionati (terzo layer), il tutto per predire i risultati dei sei task (Problem, Resolution, Spare, Spare quantity, Spare codes). Si ottiene dalla valutazione sperimentale un’accuratezza dell’ultimo layer (modelli di apprendimento ML) per il task Problem del 59.3%, del 67.0% per Resolution e del 57.6% per Spare raggiungendo il 97.3% di accuratezza per task di minore dimensionalità come Spare_codes e Spare_Qty, valori che non considerano l’intervento dei precedenti due layer. L’indagine dello spazio geometrico ha portato alla luce diverse limitazioni, tra cui una 1-NN purity al 40.4% e tassi di isolamento fino all’85%, a cui si associano i tentativi di risoluzione tramite l’ablazione delle capacità del modello di transformer con l’utilizzo della versione base del medesimo. Il tutto porta alla dimostrazione che il vero collo di bottiglia risiede nel rumore strutturale intrinseco ai dati di input, e non alle capacità algoritmiche, offrendo in maniera prospettivistica un’area di lavoro utile alla pulizia dei dati e all’integrazione dell’operato nei flussi di lavoro ospedalieri. La dashboard risulta, dunque, essere uno strumento da affinare sotto il punto di vista delle metriche, tuttavia l’utilizzabilità, seppur ancora bassa, a prescindere da futuri incrementi di accuratezza, non deve mai essere resa indipendente dal controllo umano.

Dashboard di supporto per la gestione delle tecnologie sanitarie : classificazione NLP degli ordini di lavoro per l'ingegneria clinica ospedaliera

Aiello, Giuseppe
2025/2026

Abstract

In high-complexity healthcare facilities such as the Papa Giovanni XXIII hospital in Bergamo, the management of medical devices requires a strong effort, especially for the analysis of maintenance records. In CMMS (Computerized Maintenance Management System), the description of a failure or a repair is written in natural language, very often through abbreviations, acronyms, or jargon terms that hinder the aggregate analysis of the request, slowing down process automation. The present thesis work proposes a dashboard to support the decision-making activities of the SC Clinical Engineering based on a three-layer cascaded multi-task architecture: deterministic lexical rules (first layer), semantic prototypes obtained from dense vector representations generated by the multilingual-e5-small transformer (second layer), and, finally, a weighted ensemble on four supervised Machine Learning models (third layer), all to predict the results of the six tasks (Problem, Resolution, Spare, Spare quantity, Spare codes). From the experimental evaluation, an accuracy of 59.3% emerges for the Problem task, 67.0% for Resolution, and 57.6% for Spare, reaching 97.3% accuracy for lower dimensionality tasks. The investigation of the geometric space brought to light several limitations, including a 1-NN purity of 40.4% and isolation rates up to 85%, associated with resolution attempts through the ablation of the transformer model's capacity using the base version of the same. All this leads to the demonstration that the real bottleneck lies in the structural noise intrinsic to the input data, and not in the algorithmic capabilities, prospectively offering a useful workspace for data cleaning and for the integration of the work into hospital workflows.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
In strutture sanitarie ad alta complessità come l’ospedale Papa Giovanni XXIII di Bergamo la gestione dei dispositivi medici richiede un forte impegno, in particolare per l’analisi dei registri manutentivi. Nei CMMS (Computerized Maintenance Management System) la descrizione di un guasto o di una riparazione è redatta in linguaggio naturale, molto spesso attraverso sigle, acronimi o termini gergali che ostacolano l’analisi aggregata della richiesta, rallentando l’automazione del processo. Il lavoro di tesi presente propone una dashboard di supporto alle attività di decision making della SC Ingegneria Clinica che si fonda su di un’architettura multi-task a cascata su tre layer: regole deterministiche lessicali (primo layer) prototipi semantici ottenuti da rappresentazioni vettoriali dense generate dal transformer multilingual-e5 small (secondo layer) e, infine, un ensemble pesato su quattro modelli di Machine Learning supervisionati (terzo layer), il tutto per predire i risultati dei sei task (Problem, Resolution, Spare, Spare quantity, Spare codes). Si ottiene dalla valutazione sperimentale un’accuratezza dell’ultimo layer (modelli di apprendimento ML) per il task Problem del 59.3%, del 67.0% per Resolution e del 57.6% per Spare raggiungendo il 97.3% di accuratezza per task di minore dimensionalità come Spare_codes e Spare_Qty, valori che non considerano l’intervento dei precedenti due layer. L’indagine dello spazio geometrico ha portato alla luce diverse limitazioni, tra cui una 1-NN purity al 40.4% e tassi di isolamento fino all’85%, a cui si associano i tentativi di risoluzione tramite l’ablazione delle capacità del modello di transformer con l’utilizzo della versione base del medesimo. Il tutto porta alla dimostrazione che il vero collo di bottiglia risiede nel rumore strutturale intrinseco ai dati di input, e non alle capacità algoritmiche, offrendo in maniera prospettivistica un’area di lavoro utile alla pulizia dei dati e all’integrazione dell’operato nei flussi di lavoro ospedalieri. La dashboard risulta, dunque, essere uno strumento da affinare sotto il punto di vista delle metriche, tuttavia l’utilizzabilità, seppur ancora bassa, a prescindere da futuri incrementi di accuratezza, non deve mai essere resa indipendente dal controllo umano.
File allegati
File Dimensione Formato  
2026_10_Aiello.pdf

solo utenti autorizzati a partire dal 13/09/2029

Descrizione: Documento di Tesi
Dimensione 4.16 MB
Formato Adobe PDF
4.16 MB Adobe PDF   Visualizza/Apri
2026_10_Aiello_Executive Summary.pdf

solo utenti autorizzati a partire dal 23/09/2027

Descrizione: Executive Summary
Dimensione 891.81 kB
Formato Adobe PDF
891.81 kB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/264597