Electrotactile stimulation offers a promising way to convey artificial sensory information through the skin and may provide an additional communication channel for human–machine interaction. This thesis investigated the fidelity of frequency-based electrotactile perception by characterizing individual frequency-discrimination sensitivity, repeatability across sessions and the effects of stimulation frequency, pulse width and stimulus duration. Eighteen healthy participants completed two experimental sessions in which their individual usable pulse-width range was first determined, followed by a two-alternative forced-choice (2AFC) frequency-discrimination task around reference frequencies of 20 and 50 Hz. Psychometric functions were used to estimate Just Noticeable Differences (JNDs). Frequency discrimination was significantly more precise at 20 Hz than at 50 Hz and this difference remained consistent across the two experimental sessions. Substantial inter-individual variability was observed in frequency-discrimination sensitivity. Longer stimulus duration improved discrimination at 50 Hz, but not significantly at 20 Hz. JND was not significantly associated with target pulse width. Overall, these findings support stimulation frequency as a viable dimension for electrotactile communication, while indicating that frequency-based coding should be adapted to the operating frequency and to the perceptual sensitivity of each user.
La stimolazione elettrotattile rappresenta un metodo promettente per trasmettere informazioni sensoriali artificiali attraverso la pelle e può fornire un canale di comunicazione aggiuntivo per l’interazione uomo–macchina. Questa tesi ha studiato la fedeltà della percezione elettrotattile basata sulla frequenza, caratterizzando la sensibilità individuale alla discriminazione della frequenza, la ripetibilità tra sessioni e gli effetti della frequenza di stimolazione, della larghezza dell’impulso e della durata dello stimolo. Diciotto partecipanti sani hanno completato due sessioni sperimentali, nelle quali è stato inizialmente determinato il loro intervallo individuale utilizzabile di larghezza dell’impulso, seguito da un compito di discriminazione della frequenza a scelta forzata tra due alternative (2AFC) attorno a frequenze di riferimento di 20 e 50 Hz. Sono state utilizzate funzioni psicometriche per stimare le differenze appena percepibili (Just Noticeable Differences, JND). La discriminazione della frequenza è risultata significativamente più precisa a 20 Hz rispetto a 50 Hz e tale differenza è rimasta consistente nelle due sessioni sperimentali. È stata osservata una sostanziale variabilità inter-individuale nella sensibilità alla discriminazione della frequenza. Una maggiore durata dello stimolo ha migliorato la discriminazione a 50 Hz, ma non in modo significativo a 20 Hz. La JND non è risultata significativamente associata alla larghezza dell’impulso target. Nel complesso, questi risultati supportano l’utilizzo della frequenza di stimolazione come una dimensione valida per la comunicazione elettrotattile, indicando al contempo che la codifica basata sulla frequenza dovrebbe essere adattata alla frequenza operativa e alla sensibilità percettiva di ciascun utente.
The fidelity of prosthetic electrotactile senses
MERLO, FRANCESCO
2025/2026
Abstract
Electrotactile stimulation offers a promising way to convey artificial sensory information through the skin and may provide an additional communication channel for human–machine interaction. This thesis investigated the fidelity of frequency-based electrotactile perception by characterizing individual frequency-discrimination sensitivity, repeatability across sessions and the effects of stimulation frequency, pulse width and stimulus duration. Eighteen healthy participants completed two experimental sessions in which their individual usable pulse-width range was first determined, followed by a two-alternative forced-choice (2AFC) frequency-discrimination task around reference frequencies of 20 and 50 Hz. Psychometric functions were used to estimate Just Noticeable Differences (JNDs). Frequency discrimination was significantly more precise at 20 Hz than at 50 Hz and this difference remained consistent across the two experimental sessions. Substantial inter-individual variability was observed in frequency-discrimination sensitivity. Longer stimulus duration improved discrimination at 50 Hz, but not significantly at 20 Hz. JND was not significantly associated with target pulse width. Overall, these findings support stimulation frequency as a viable dimension for electrotactile communication, while indicating that frequency-based coding should be adapted to the operating frequency and to the perceptual sensitivity of each user.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_10_Merlo_Executive_Summary.pdf
accessibile in internet per tutti a partire dal 28/09/2029
Descrizione: Executive Summary Francesco Merlo
Dimensione
2.68 MB
Formato
Adobe PDF
|
2.68 MB | Adobe PDF | Visualizza/Apri |
|
2026_10_Merlo_Tesi.pdf
accessibile in internet per tutti a partire dal 28/09/2029
Descrizione: Testo della tesi Francesco Merlo
Dimensione
7.8 MB
Formato
Adobe PDF
|
7.8 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/265297