Phase-contrast X-ray imaging represents an advanced technique for visualizing materials and structures characterized by low absorption contrast, overcoming some of the limitations of conventional radiography. Although these methodologies were primarily developed at synchrotron sources, growing interest in more accessible systems has stimulated their use in laboratory settings. In this work, a complete procedure for propagation-based phase-contrast tomography(PB-PCI) was developed and validated using a laboratory nano/micro-focus X-ray source. The methodology includes characterization of the source spectrum, evaluation of the energy response of a CdZnTe detector using Monte Carlo simulations, and determination of the effective beam energy. The Paganin phase retrieval method was subsequently implemented, analyzing its influence on image quality and optimizing the processing parameters. The procedure has been applied to biological and engineering samples, allowing three-dimensional tomographic reconstruction of internal structures. The results demonstrate the feasibility of phase-contrast tomography with laboratory sources and confirm how phase retrieval improves the contrast and visibility of weakly absorbing structures, making this technique a valid alternative for numerous scientific and industrial applications.

L’imaging a raggi X a contrasto di fase rappresenta una tecnica avanzata per la visualizzazione di materiali e strutture caratterizzati da basso contrasto di assorbimento, consenten do di superare alcune limitazioni della radiografia convenzionale. Sebbene tali metodologie siano state sviluppate principalmente presso sorgenti di sincrotrone, il crescente interesse verso sistemi più accessibili ha stimolato il loro impiego in ambiente di laboratorio. In questo lavoro è stata sviluppata e validata una procedura completa per la tomografia a contrasto di fase basata sulla propagazione (Propagation-Based Phase Contrast Imaging, PB-PCI) utilizzando una sorgente X nano/micro-focus da laboratorio. La metodologia comprende la caratterizzazione dello spettro della sorgente, la valutazione della risposta energetica di un rivelatore CdZnTe mediante simulazioni Monte Carlo e la determinazione dell’energia efficace del fascio. Successivamente è stato implementato il metodo di phase retrieval di Paganin, analizzandone l’influenza sulla qualità delle immagini e ottimizzando i parametri di elaborazione. La procedura è stata applicata a campioni di natura biologica e ingegneristica, consentendo la ricostruzione tomografica tridimensionale delle strutture interne. I risultati dimostrano la fattibilità della tomografia a contrasto di fase con sorgenti da laboratorio e confermano come il phase retrieval migliori il contrasto e la visibilità di strutture debolmente assorbenti, rendendo questa tecnica una valida alternativa per numerose applicazioni scientifiche e industriali.

Propagation-based phase-contrast X-ray imaging with a laboratory source: development and validation

Bicelli, Federica
2025/2026

Abstract

Phase-contrast X-ray imaging represents an advanced technique for visualizing materials and structures characterized by low absorption contrast, overcoming some of the limitations of conventional radiography. Although these methodologies were primarily developed at synchrotron sources, growing interest in more accessible systems has stimulated their use in laboratory settings. In this work, a complete procedure for propagation-based phase-contrast tomography(PB-PCI) was developed and validated using a laboratory nano/micro-focus X-ray source. The methodology includes characterization of the source spectrum, evaluation of the energy response of a CdZnTe detector using Monte Carlo simulations, and determination of the effective beam energy. The Paganin phase retrieval method was subsequently implemented, analyzing its influence on image quality and optimizing the processing parameters. The procedure has been applied to biological and engineering samples, allowing three-dimensional tomographic reconstruction of internal structures. The results demonstrate the feasibility of phase-contrast tomography with laboratory sources and confirm how phase retrieval improves the contrast and visibility of weakly absorbing structures, making this technique a valid alternative for numerous scientific and industrial applications.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
L’imaging a raggi X a contrasto di fase rappresenta una tecnica avanzata per la visualizzazione di materiali e strutture caratterizzati da basso contrasto di assorbimento, consenten do di superare alcune limitazioni della radiografia convenzionale. Sebbene tali metodologie siano state sviluppate principalmente presso sorgenti di sincrotrone, il crescente interesse verso sistemi più accessibili ha stimolato il loro impiego in ambiente di laboratorio. In questo lavoro è stata sviluppata e validata una procedura completa per la tomografia a contrasto di fase basata sulla propagazione (Propagation-Based Phase Contrast Imaging, PB-PCI) utilizzando una sorgente X nano/micro-focus da laboratorio. La metodologia comprende la caratterizzazione dello spettro della sorgente, la valutazione della risposta energetica di un rivelatore CdZnTe mediante simulazioni Monte Carlo e la determinazione dell’energia efficace del fascio. Successivamente è stato implementato il metodo di phase retrieval di Paganin, analizzandone l’influenza sulla qualità delle immagini e ottimizzando i parametri di elaborazione. La procedura è stata applicata a campioni di natura biologica e ingegneristica, consentendo la ricostruzione tomografica tridimensionale delle strutture interne. I risultati dimostrano la fattibilità della tomografia a contrasto di fase con sorgenti da laboratorio e confermano come il phase retrieval migliori il contrasto e la visibilità di strutture debolmente assorbenti, rendendo questa tecnica una valida alternativa per numerose applicazioni scientifiche e industriali.
File allegati
File Dimensione Formato  
2026_10_Bicelli_Executive_Summary.pdf

non accessibile

Descrizione: Executive Summary
Dimensione 8.7 MB
Formato Adobe PDF
8.7 MB Adobe PDF   Visualizza/Apri
2026_10_Bicelli.pdf

non accessibile

Descrizione: testo tesi
Dimensione 60.78 MB
Formato Adobe PDF
60.78 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/265818