Computational biomechanics plays a key role in understanding lumbar spine pathologies, such as lower back pain. However, most Finite Element models simplify soft tissues by using 1D spring elements and idealized joints, compromising their anatomical fidelity, oversimplifying the complex spatial interactions between tissues and failing to capture the true 3D stress distribution inside the anatomy. Addressing this gap, this thesis develops a fully volumetric 3D computational model of a patient-specific lumbar Functional Spinal Unit (L3-L4). To obtain realistic geometries, the facet joints and ligaments were carefully reconstructed and appropriately remeshed. Once the monolithic mesh was created, it was imported into the open-source solver FEniCS to implement complex non-linear materials. Specifically, a penalty formulation was used for the nucleus pulposus, the Holzapfel-Gasser-Ogden (HGO) formulation for the annulus fibrosus, and the Weiss model to replicate the tension-only behavior of ligamentous collagen fibers. Additionally, to avoid the computational complexity often associated with frictionless sliding contacts, the facet joints were modeled as continuous solid blocks with a calibrated equivalent stiffness of 2.28 MPa. The impact of these modeling choices was progressively evaluated under physiological loads, including flexion, extension, lateral bending, and axial torsion. The results showed that the equivalent stiffness approach successfully prevented shear locking, allowing natural movements while still acting as a mechanical stop. At the same time, the volumetric ligaments correctly reproduced their biological tension-only function, naturally slackening under compression. Both the macroscopic Range of Motion (ROM) and internal stress distributions matched established literature targets, thus this study demonstrates that a fully 3D continuum model can achieve the kinematic accuracy of traditional simplified models, offering a more detailed framework for tissue-level analyses.
La biomeccanica computazionale ha un ruolo chiave nello studio di patologie lombari come la lombalgia. Tuttavia, molti modelli ad Elementi Finiti semplificano i tessuti molli utilizzando molle monodimensionali (1D) e giunti idealizzati, compromettendone la fedeltà anatomica, semplificando eccessivamente le complesse interazioni spaziali tra i tessuti e perdendo la reale distribuzione tridimensionale degli sforzi. Per colmare questa lacuna, questa tesi propone un modello computazionale 3D interamente volumetrico di un'Unità Spinale Funzionale lombare (L3-L4) paziente-specifica. Per ottenere geometrie realistiche, le faccette articolari (in particolare il complesso formato da piatti cartilaginei e capsula articolare) e i legamenti sono stati ricostruiti nel dettaglio e sottoposti ad un remeshing mirato, ricorrendo in particolare a una tecnica di estrusione strato per strato per generare legamenti longitudinali 3D conformi. La mesh monolitica è stata poi importata nel solutore open-source FEniCS per applicare modelli non lineari: una formulazione a penalità per il nucleo polposo, la formulazione di Holzapfel-Gasser-Ogden (HGO) per l'annulus fibroso e il modello di Weiss per replicare il comportamento a sola trazione delle fibre di collagene nei legamenti. Inoltre, per evitare la complessità numerica tipica dei modelli di contatto, le faccette articolari sono state modellate come blocchi solidi continui, assegnando loro una rigidezza equivalente calibrata (2.28 MPa). L'impatto di queste scelte modellistiche è stato valutato progressivamente simulando carichi fisiologici di flessione, estensione, piegamento laterale e torsione assiale. I risultati hanno dimostrato che l'approccio con rigidezza equivalente previene efficacemente la resistenza a taglio, consentendo movimenti naturali pur fungendo da fine-corsa meccanico. Allo stesso tempo, i legamenti volumetrici hanno riprodotto correttamente la loro funzione biologica, detensionandosi spontaneamente sotto carichi compressivi. Considerando che sia i Range of Motion (ROM) che le distribuzioni degli sforzi interni hanno rispecchiato fedelmente i target di letteratura, questo studio dimostra come un modello 3D continuo riesca a eguagliare l'accuratezza cinematica dei modelli semplificati, offrendo una base molto più solida e dettagliata per analisi biomeccaniche tissutali.
Computational modeling of a lumbar functional spinal unit: a 3D volumetric approach to ligament and facet joint biomechanics
Bianchi, Giorgia
2025/2026
Abstract
Computational biomechanics plays a key role in understanding lumbar spine pathologies, such as lower back pain. However, most Finite Element models simplify soft tissues by using 1D spring elements and idealized joints, compromising their anatomical fidelity, oversimplifying the complex spatial interactions between tissues and failing to capture the true 3D stress distribution inside the anatomy. Addressing this gap, this thesis develops a fully volumetric 3D computational model of a patient-specific lumbar Functional Spinal Unit (L3-L4). To obtain realistic geometries, the facet joints and ligaments were carefully reconstructed and appropriately remeshed. Once the monolithic mesh was created, it was imported into the open-source solver FEniCS to implement complex non-linear materials. Specifically, a penalty formulation was used for the nucleus pulposus, the Holzapfel-Gasser-Ogden (HGO) formulation for the annulus fibrosus, and the Weiss model to replicate the tension-only behavior of ligamentous collagen fibers. Additionally, to avoid the computational complexity often associated with frictionless sliding contacts, the facet joints were modeled as continuous solid blocks with a calibrated equivalent stiffness of 2.28 MPa. The impact of these modeling choices was progressively evaluated under physiological loads, including flexion, extension, lateral bending, and axial torsion. The results showed that the equivalent stiffness approach successfully prevented shear locking, allowing natural movements while still acting as a mechanical stop. At the same time, the volumetric ligaments correctly reproduced their biological tension-only function, naturally slackening under compression. Both the macroscopic Range of Motion (ROM) and internal stress distributions matched established literature targets, thus this study demonstrates that a fully 3D continuum model can achieve the kinematic accuracy of traditional simplified models, offering a more detailed framework for tissue-level analyses.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_10_Bianchi_Giorgia_Executive_Summary.pdf
non accessibile
Dimensione
4.43 MB
Formato
Adobe PDF
|
4.43 MB | Adobe PDF | Visualizza/Apri |
|
2026_10_Bianchi_Giorgia_Thesis.pdf
non accessibile
Descrizione: Thesis on computational modeling of a lumbar functional spinal unit
Dimensione
10.45 MB
Formato
Adobe PDF
|
10.45 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/266001