This thesis presents the development, optimization, and evaluation of a multimodal Intra-Oral Respirometer (IoR) for continuous respiratory and cardiovascular monitoring. The device is embedded in a subject-specific thermoformed retainer and integrates respiratory pressure sensing, photoplethysmography (PPG), inertial sensing, occlusal-force sensing, wireless inductive charging, Bluetooth Low Energy telemetry, and a real-time user interface within a single wearable platform. A custom flexible PPG board conforms to the palatal curvature and positions its optical window against the mucosa over the expected course of the greater palatine artery. The primary aim of this work was to validate the intra-oral heart-rate estimate at the cohort level and to characterize the respiratory pressure signal under static and dynamic conditions. Ten healthy participants (N = 10, five male and five female) completed five experimental blocks comprising instructed breathing maneuvers, nasal and mouth breathing at rest, and dynamic activities ranging from walking to running and jumping jacks. Two simultaneously recorded Polar Verity Sense monitors provided optical heart-rate references. In the static breathing-conditions block, the cohort median of the per-subject mean absolute errors was 2.73 bpm against the headband reference and 2.16 bpm against the armband reference, compared with 1.04 bpm between the two references. During light activity, heart-rate error remained approximately 3 bpm across all three dynamic protocols, although agreement became less stable during vigorous whole-body movement. The respiratory pressure signal distinguished the instructed breathing patterns, with significant differences in respiratory rate (p = 7.7 × 10^-8) and pressure amplitude (p = 0.001). During rapid-and-shallow breathing, eight of ten subjects simultaneously increased respiratory rate and reduced pressure amplitude, showing that the two pressure-derived metrics provide distinct information. During spontaneous dynamic activity, both respiratory rate and pressure amplitude increased systematically across the ordered activity conditions (Page trend: p = 2.4 × 10^-8 and p = 8.0 × 10^-7, respectively). Breathing route further modified the pressure-amplitude response to activity: amplitude increased during nasal breathing but remained approximately flat during mouth breathing, producing a significant route-by-activity interaction (-0.32, p = 0.017), whereas respiratory rate increased under both routes. Overall, this work provides the first cohort-level validation of the IoR intra-oral heart-rate estimate and advances the platform toward integrated respiratory and cardiovascular monitoring within a single intra-oral wearable.

Questa tesi presenta lo sviluppo, l'ottimizzazione e la valutazione di un respirometro intraorale multimodale (IoR) per il monitoraggio continuo respiratorio e cardiovascolare. Il dispositivo è integrato in un retainer termoformato specifico per il soggetto e combina il rilevamento della pressione respiratoria, la fotopletismografia (PPG), il rilevamento inerziale, la misura della forza occlusale, la ricarica wireless a induzione, la telemetria Bluetooth Low Energy e un'interfaccia utente in tempo reale all'interno di un'unica piattaforma indossabile. Una scheda PPG flessibile realizzata su misura si conforma alla curvatura del palato e posiziona la finestra ottica a contatto con la mucosa in corrispondenza del decorso atteso dell'arteria palatina maggiore. L'obiettivo principale di questo lavoro è stato validare, a livello di coorte, la stima della frequenza cardiaca ottenuta mediante l'IoR e caratterizzare il segnale di pressione respiratoria in condizioni statiche e dinamiche. Dieci partecipanti sani (N = 10, cinque uomini e cinque donne) hanno completato cinque blocchi sperimentali comprendenti manovre respiratorie guidate, respirazione nasale e orale a riposo e attività dinamiche dal cammino alla corsa e ai jumping jacks. Due monitor Polar Verity Sense utilizzati simultaneamente sono stati impiegati come riferimenti ottici per la frequenza cardiaca. Nel blocco statico delle condizioni respiratorie, la mediana di coorte degli errori assoluti medi calcolati per soggetto è risultata pari a 2.73 bpm rispetto al riferimento sulla testa e a 2.16 bpm rispetto al riferimento sul braccio, contro 1.04 bpm fra i due riferimenti. Durante l'attività leggera, l'errore della frequenza cardiaca è rimasto intorno a 3 bpm in tutti e tre i protocolli dinamici, sebbene l'accordo sia risultato meno stabile durante i movimenti vigorosi dell'intero corpo. Il segnale di pressione respiratoria ha distinto le manovre respiratorie guidate, con differenze significative sia nella frequenza respiratoria (p = 7.7 × 10^-8) sia nell'ampiezza di pressione (p = 0.001). Durante la respirazione rapida e superficiale, otto soggetti su dieci hanno contemporaneamente aumentato la frequenza respiratoria e ridotto l'ampiezza di pressione, mostrando che le due grandezze derivate dal segnale di pressione forniscono informazioni distinte. Durante l'attività dinamica spontanea, sia la frequenza respiratoria sia l'ampiezza di pressione sono aumentate sistematicamente nelle condizioni di attività ordinate per intensità (Page trend: p = 2.4 × 10^-8 e p = 8.0 × 10^-7, rispettivamente). La via respiratoria ha inoltre modificato la risposta dell'ampiezza di pressione all'attività: l'ampiezza è aumentata durante la respirazione nasale ma è rimasta approssimativamente stabile durante quella orale, determinando un'interazione significativa tra via respiratoria e attività (-0.32, p = 0.017), mentre la frequenza respiratoria è aumentata con entrambe le modalità respiratorie. Nel complesso, questo lavoro fornisce la prima validazione a livello di coorte della stima della frequenza cardiaca ottenuta mediante l'IoR e rappresenta un ulteriore passo verso il monitoraggio integrato respiratorio e cardiovascolare mediante un unico dispositivo intraorale indossabile.

Development and characterization of multimodal intra-oral respirometer for continuous respiratory and cardiovascular monitoring

DI SILVERIO, LORENZO
2025/2026

Abstract

This thesis presents the development, optimization, and evaluation of a multimodal Intra-Oral Respirometer (IoR) for continuous respiratory and cardiovascular monitoring. The device is embedded in a subject-specific thermoformed retainer and integrates respiratory pressure sensing, photoplethysmography (PPG), inertial sensing, occlusal-force sensing, wireless inductive charging, Bluetooth Low Energy telemetry, and a real-time user interface within a single wearable platform. A custom flexible PPG board conforms to the palatal curvature and positions its optical window against the mucosa over the expected course of the greater palatine artery. The primary aim of this work was to validate the intra-oral heart-rate estimate at the cohort level and to characterize the respiratory pressure signal under static and dynamic conditions. Ten healthy participants (N = 10, five male and five female) completed five experimental blocks comprising instructed breathing maneuvers, nasal and mouth breathing at rest, and dynamic activities ranging from walking to running and jumping jacks. Two simultaneously recorded Polar Verity Sense monitors provided optical heart-rate references. In the static breathing-conditions block, the cohort median of the per-subject mean absolute errors was 2.73 bpm against the headband reference and 2.16 bpm against the armband reference, compared with 1.04 bpm between the two references. During light activity, heart-rate error remained approximately 3 bpm across all three dynamic protocols, although agreement became less stable during vigorous whole-body movement. The respiratory pressure signal distinguished the instructed breathing patterns, with significant differences in respiratory rate (p = 7.7 × 10^-8) and pressure amplitude (p = 0.001). During rapid-and-shallow breathing, eight of ten subjects simultaneously increased respiratory rate and reduced pressure amplitude, showing that the two pressure-derived metrics provide distinct information. During spontaneous dynamic activity, both respiratory rate and pressure amplitude increased systematically across the ordered activity conditions (Page trend: p = 2.4 × 10^-8 and p = 8.0 × 10^-7, respectively). Breathing route further modified the pressure-amplitude response to activity: amplitude increased during nasal breathing but remained approximately flat during mouth breathing, producing a significant route-by-activity interaction (-0.32, p = 0.017), whereas respiratory rate increased under both routes. Overall, this work provides the first cohort-level validation of the IoR intra-oral heart-rate estimate and advances the platform toward integrated respiratory and cardiovascular monitoring within a single intra-oral wearable.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
Questa tesi presenta lo sviluppo, l'ottimizzazione e la valutazione di un respirometro intraorale multimodale (IoR) per il monitoraggio continuo respiratorio e cardiovascolare. Il dispositivo è integrato in un retainer termoformato specifico per il soggetto e combina il rilevamento della pressione respiratoria, la fotopletismografia (PPG), il rilevamento inerziale, la misura della forza occlusale, la ricarica wireless a induzione, la telemetria Bluetooth Low Energy e un'interfaccia utente in tempo reale all'interno di un'unica piattaforma indossabile. Una scheda PPG flessibile realizzata su misura si conforma alla curvatura del palato e posiziona la finestra ottica a contatto con la mucosa in corrispondenza del decorso atteso dell'arteria palatina maggiore. L'obiettivo principale di questo lavoro è stato validare, a livello di coorte, la stima della frequenza cardiaca ottenuta mediante l'IoR e caratterizzare il segnale di pressione respiratoria in condizioni statiche e dinamiche. Dieci partecipanti sani (N = 10, cinque uomini e cinque donne) hanno completato cinque blocchi sperimentali comprendenti manovre respiratorie guidate, respirazione nasale e orale a riposo e attività dinamiche dal cammino alla corsa e ai jumping jacks. Due monitor Polar Verity Sense utilizzati simultaneamente sono stati impiegati come riferimenti ottici per la frequenza cardiaca. Nel blocco statico delle condizioni respiratorie, la mediana di coorte degli errori assoluti medi calcolati per soggetto è risultata pari a 2.73 bpm rispetto al riferimento sulla testa e a 2.16 bpm rispetto al riferimento sul braccio, contro 1.04 bpm fra i due riferimenti. Durante l'attività leggera, l'errore della frequenza cardiaca è rimasto intorno a 3 bpm in tutti e tre i protocolli dinamici, sebbene l'accordo sia risultato meno stabile durante i movimenti vigorosi dell'intero corpo. Il segnale di pressione respiratoria ha distinto le manovre respiratorie guidate, con differenze significative sia nella frequenza respiratoria (p = 7.7 × 10^-8) sia nell'ampiezza di pressione (p = 0.001). Durante la respirazione rapida e superficiale, otto soggetti su dieci hanno contemporaneamente aumentato la frequenza respiratoria e ridotto l'ampiezza di pressione, mostrando che le due grandezze derivate dal segnale di pressione forniscono informazioni distinte. Durante l'attività dinamica spontanea, sia la frequenza respiratoria sia l'ampiezza di pressione sono aumentate sistematicamente nelle condizioni di attività ordinate per intensità (Page trend: p = 2.4 × 10^-8 e p = 8.0 × 10^-7, rispettivamente). La via respiratoria ha inoltre modificato la risposta dell'ampiezza di pressione all'attività: l'ampiezza è aumentata durante la respirazione nasale ma è rimasta approssimativamente stabile durante quella orale, determinando un'interazione significativa tra via respiratoria e attività (-0.32, p = 0.017), mentre la frequenza respiratoria è aumentata con entrambe le modalità respiratorie. Nel complesso, questo lavoro fornisce la prima validazione a livello di coorte della stima della frequenza cardiaca ottenuta mediante l'IoR e rappresenta un ulteriore passo verso il monitoraggio integrato respiratorio e cardiovascolare mediante un unico dispositivo intraorale indossabile.
File allegati
File Dimensione Formato  
2026_10_DiSilverio_Tesi.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 54.68 MB
Formato Adobe PDF
54.68 MB Adobe PDF   Visualizza/Apri
2026_10_DiSilverio_Executive_Summary.pdf

non accessibile

Descrizione: Executive Summary
Dimensione 1.13 MB
Formato Adobe PDF
1.13 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266039