The Smart Readiness Indicator (SRI), introduced under the European Union's Energy Performance of Buildings Directive, currently assesses buildings through two static, inspection based tiers, Method A and Method B, which certify a building's theoretical potential rather than its verified operational performance. A third tier, Method C, based on metered operational data from IoT sensors and building automation systems, is described in the regulatory literature as a potential future evolution of the framework, but no validated, publicly documented implementation of it exists to date. This absence is the starting point of this thesis, conducted within the European tunES project ahead of the European Commission's 30 June 2026 report to the Parliament on Method C's testing and implementation under Article 15 of the 2024 EPBD recast. This research designs, implements, and empirically tests an automated Method C logic engine on a single case study, a renovated, semi-detached residential villa in Northern Italy referred to as “Villa Segrate” within the Mediterranean climatic zone the tunES project has identified as underserved by the SRI's current, Northern European calibrated weighting scheme. The engine reads historical CSV data exported from the building's home automation platform, covering a primary monitoring period of 1 January 2026 to 31 August 2026, and applies the official SRI v4.5 catalogue criteria across all 54 services, grouped into 9 domains, through an equal number of independent evaluation functions, calculating a final score using the same formulas defined in Commission Delegated Regulation (EU) 2020/2155. A strict evidence hierarchy keeps this historical, dynamic data entirely separate from the static documentary evidence; the Digital Building Logbook, home automation dashboard screenshots, and IFC models, used for an independently conducted Method B assessment of the same building. A four-state applicability framework, verified, partial evidence, unresolved, and not applicable, makes the engine's confidence in each assigned functionality level explicit rather than concealing it inside a single number. The Method C engine produced a final SRI score of 31.90%, Class F, with all 54 services resolved to a verified functionality level following a full review against the official calculation sheet. The independently conducted Method B assessment scored 18.47%, Class G, a 13.43 percentage point divergence concentrated specifically in services where the building's systems are more capable than its documentation alone could demonstrate, geofencing based presence detection, automatic ventilation heat recovery bypass, and sustained solar utilization, while both methods converged where automation was genuinely absent. The building's IFC models were found to have largely empty property sets, a documented technical reason this thesis pursues IoT based automation rather than a Digital Twin built on a synchronized BIM model, and the engine's own output was reconciled, at a single building scale, with the Digital Building Logbook the building already has rather than a new platform. This thesis contributes an empirically tested implementation of a methodology tier the literature has so far only described in principle, a granular, service level uncertainty handling framework applicable beyond this case study, and a tested, if labor intensive, path for reconciling automated SRI output with existing building documentation. The calculation logic developed here is structured independently of its prototype interface so that it can be reused as a backend module within the Digital Building Logbook portal maintained by the University of Brescia's Habitech initiative under the tunES collaboration, an integration this thesis's technical development chapter documents explicitly. Cybersecurity protocols and the economic dimensions of adopting this approach at scale remain outside its scope and are identified as directions for future research.

Lo Smart Readiness Indicator (SRI), introdotto nell'ambito della direttiva europea sulla prestazione energetica nell'edilizia, valuta attualmente gli edifici attraverso due livelli statici, basati su ispezione, il Metodo A e il Metodo B, che certificano il potenziale teorico di un edificio piuttosto che la sua prestazione operativa verificata. Un terzo livello, il Metodo C, basato su dati operativi misurati provenienti da sensori IoT e sistemi di automazione degli edifici, è descritto nella letteratura regolatoria come una possibile evoluzione futura del quadro metodologico, ma ad oggi non esiste alcuna implementazione validata e pubblicamente documentata. Questa assenza è il punto di partenza della presente tesi, condotta nell'ambito del progetto europeo tunES in vista della relazione che la Commissione Europea dovrà presentare al Parlamento entro il 30 giugno 2026 sulla sperimentazione e l'implementazione del Metodo C, ai sensi dell'Articolo 15 della direttiva EPBD rifusa nel 2024. Questa ricerca progetta, implementa e testa empiricamente un motore logico automatizzato per il Metodo C su un singolo caso di studio, una villa residenziale bifamiliare ristrutturata nel Nord Italia, indicata come Villa Segrate, situata nella zona climatica mediterranea che il progetto tunES ha identificato come penalizzata dall'attuale sistema di pesi dell'SRI, calibrato su un contesto nordeuropeo. Il motore legge dati storici in formato CSV esportati dalla piattaforma di domotica dell'edificio, relativi a un periodo di monitoraggio principale dal 1° gennaio 2026 al 31 agosto 2026, e applica i criteri ufficiali del catalogo SRI v4.5 a tutti i 54 servizi, raggruppati in 9 domini, attraverso altrettante funzioni di valutazione indipendenti, calcolando il punteggio finale con le stesse formule definite nel Regolamento Delegato (UE) 2020/2155 della Commissione. Una rigida gerarchia delle evidenze mantiene questi dati dinamici e storici completamente separati dall'evidenza documentale statica, il Digital Building Logbook, le schermate del cruscotto domotico e i modelli IFC, utilizzata per una valutazione Metodo B condotta in modo indipendente sullo stesso edificio. Un sistema a quattro stati di applicabilità, verificato, evidenza parziale, non risolto e non applicabile, rende esplicito il livello di confidenza del motore per ciascun livello di funzionalità assegnato, invece di occultarlo in un unico valore numerico. Il motore per il Metodo C ha prodotto un punteggio SRI finale del 31,90%, Classe F, con tutti i 54 servizi risolti a un livello di funzionalità verificato dopo una revisione completa rispetto alla scheda di calcolo ufficiale. La valutazione Metodo B, condotta indipendentemente, ha ottenuto un punteggio del 18,47%, Classe G, con una divergenza di 13,43 punti percentuali concentrata specificamente nei servizi in cui i sistemi dell'edificio risultano più capaci di quanto la sola documentazione potesse dimostrare, il rilevamento di presenza tramite geofencing, il bypass automatico di recupero di calore della ventilazione e un utilizzo solare sostenuto, mentre i due metodi convergono laddove l'automazione è genuinamente assente. I modelli IFC dell'edificio presentano property set in gran parte vuoti, motivazione tecnica documentata per cui questa tesi persegue un'automazione basata su IoT piuttosto che un Digital Twin fondato su un modello BIM sincronizzato, e l'output del motore è stato riconciliato, alla scala di un singolo edificio, con il Digital Building Logbook già esistente, senza richiedere una nuova piattaforma. Questa tesi contribuisce con un'implementazione empiricamente testata di un livello metodologico finora descritto solo in linea di principio, un sistema granulare di gestione dell'incertezza a livello di singolo servizio applicabile oltre questo caso di studio, e un percorso testato, seppur laborioso, per riconciliare l'output SRI automatizzato con la documentazione edilizia esistente. La logica di calcolo qui sviluppata è strutturata in modo indipendente dalla sua interfaccia prototipale, così da poter essere riutilizzata come modulo backend all'interno del portale Digital Building Logbook mantenuto dall'iniziativa Habitech dell'Università di Brescia nell'ambito della collaborazione tunES, un'integrazione documentata esplicitamente nel capitolo dedicato allo sviluppo tecnico di questa tesi. I protocolli di cybersicurezza e le dimensioni economiche dell'adozione di questo approccio su larga scala restano fuori dall'ambito della ricerca e sono identificati come direzioni per lavori futuri.

Operationalizing SRI Method C: an IoT-Based logic engine for automated smart readiness certification in a mediterranean residential case study

DOSSMAN BORDA, DANIEL ALBERTO;Villamizar Guzman, Maria Catalina
2025/2026

Abstract

The Smart Readiness Indicator (SRI), introduced under the European Union's Energy Performance of Buildings Directive, currently assesses buildings through two static, inspection based tiers, Method A and Method B, which certify a building's theoretical potential rather than its verified operational performance. A third tier, Method C, based on metered operational data from IoT sensors and building automation systems, is described in the regulatory literature as a potential future evolution of the framework, but no validated, publicly documented implementation of it exists to date. This absence is the starting point of this thesis, conducted within the European tunES project ahead of the European Commission's 30 June 2026 report to the Parliament on Method C's testing and implementation under Article 15 of the 2024 EPBD recast. This research designs, implements, and empirically tests an automated Method C logic engine on a single case study, a renovated, semi-detached residential villa in Northern Italy referred to as “Villa Segrate” within the Mediterranean climatic zone the tunES project has identified as underserved by the SRI's current, Northern European calibrated weighting scheme. The engine reads historical CSV data exported from the building's home automation platform, covering a primary monitoring period of 1 January 2026 to 31 August 2026, and applies the official SRI v4.5 catalogue criteria across all 54 services, grouped into 9 domains, through an equal number of independent evaluation functions, calculating a final score using the same formulas defined in Commission Delegated Regulation (EU) 2020/2155. A strict evidence hierarchy keeps this historical, dynamic data entirely separate from the static documentary evidence; the Digital Building Logbook, home automation dashboard screenshots, and IFC models, used for an independently conducted Method B assessment of the same building. A four-state applicability framework, verified, partial evidence, unresolved, and not applicable, makes the engine's confidence in each assigned functionality level explicit rather than concealing it inside a single number. The Method C engine produced a final SRI score of 31.90%, Class F, with all 54 services resolved to a verified functionality level following a full review against the official calculation sheet. The independently conducted Method B assessment scored 18.47%, Class G, a 13.43 percentage point divergence concentrated specifically in services where the building's systems are more capable than its documentation alone could demonstrate, geofencing based presence detection, automatic ventilation heat recovery bypass, and sustained solar utilization, while both methods converged where automation was genuinely absent. The building's IFC models were found to have largely empty property sets, a documented technical reason this thesis pursues IoT based automation rather than a Digital Twin built on a synchronized BIM model, and the engine's own output was reconciled, at a single building scale, with the Digital Building Logbook the building already has rather than a new platform. This thesis contributes an empirically tested implementation of a methodology tier the literature has so far only described in principle, a granular, service level uncertainty handling framework applicable beyond this case study, and a tested, if labor intensive, path for reconciling automated SRI output with existing building documentation. The calculation logic developed here is structured independently of its prototype interface so that it can be reused as a backend module within the Digital Building Logbook portal maintained by the University of Brescia's Habitech initiative under the tunES collaboration, an integration this thesis's technical development chapter documents explicitly. Cybersecurity protocols and the economic dimensions of adopting this approach at scale remain outside its scope and are identified as directions for future research.
ARC I - Scuola di Architettura Urbanistica Ingegneria delle Costruzioni
21-ott-2026
2025/2026
Lo Smart Readiness Indicator (SRI), introdotto nell'ambito della direttiva europea sulla prestazione energetica nell'edilizia, valuta attualmente gli edifici attraverso due livelli statici, basati su ispezione, il Metodo A e il Metodo B, che certificano il potenziale teorico di un edificio piuttosto che la sua prestazione operativa verificata. Un terzo livello, il Metodo C, basato su dati operativi misurati provenienti da sensori IoT e sistemi di automazione degli edifici, è descritto nella letteratura regolatoria come una possibile evoluzione futura del quadro metodologico, ma ad oggi non esiste alcuna implementazione validata e pubblicamente documentata. Questa assenza è il punto di partenza della presente tesi, condotta nell'ambito del progetto europeo tunES in vista della relazione che la Commissione Europea dovrà presentare al Parlamento entro il 30 giugno 2026 sulla sperimentazione e l'implementazione del Metodo C, ai sensi dell'Articolo 15 della direttiva EPBD rifusa nel 2024. Questa ricerca progetta, implementa e testa empiricamente un motore logico automatizzato per il Metodo C su un singolo caso di studio, una villa residenziale bifamiliare ristrutturata nel Nord Italia, indicata come Villa Segrate, situata nella zona climatica mediterranea che il progetto tunES ha identificato come penalizzata dall'attuale sistema di pesi dell'SRI, calibrato su un contesto nordeuropeo. Il motore legge dati storici in formato CSV esportati dalla piattaforma di domotica dell'edificio, relativi a un periodo di monitoraggio principale dal 1° gennaio 2026 al 31 agosto 2026, e applica i criteri ufficiali del catalogo SRI v4.5 a tutti i 54 servizi, raggruppati in 9 domini, attraverso altrettante funzioni di valutazione indipendenti, calcolando il punteggio finale con le stesse formule definite nel Regolamento Delegato (UE) 2020/2155 della Commissione. Una rigida gerarchia delle evidenze mantiene questi dati dinamici e storici completamente separati dall'evidenza documentale statica, il Digital Building Logbook, le schermate del cruscotto domotico e i modelli IFC, utilizzata per una valutazione Metodo B condotta in modo indipendente sullo stesso edificio. Un sistema a quattro stati di applicabilità, verificato, evidenza parziale, non risolto e non applicabile, rende esplicito il livello di confidenza del motore per ciascun livello di funzionalità assegnato, invece di occultarlo in un unico valore numerico. Il motore per il Metodo C ha prodotto un punteggio SRI finale del 31,90%, Classe F, con tutti i 54 servizi risolti a un livello di funzionalità verificato dopo una revisione completa rispetto alla scheda di calcolo ufficiale. La valutazione Metodo B, condotta indipendentemente, ha ottenuto un punteggio del 18,47%, Classe G, con una divergenza di 13,43 punti percentuali concentrata specificamente nei servizi in cui i sistemi dell'edificio risultano più capaci di quanto la sola documentazione potesse dimostrare, il rilevamento di presenza tramite geofencing, il bypass automatico di recupero di calore della ventilazione e un utilizzo solare sostenuto, mentre i due metodi convergono laddove l'automazione è genuinamente assente. I modelli IFC dell'edificio presentano property set in gran parte vuoti, motivazione tecnica documentata per cui questa tesi persegue un'automazione basata su IoT piuttosto che un Digital Twin fondato su un modello BIM sincronizzato, e l'output del motore è stato riconciliato, alla scala di un singolo edificio, con il Digital Building Logbook già esistente, senza richiedere una nuova piattaforma. Questa tesi contribuisce con un'implementazione empiricamente testata di un livello metodologico finora descritto solo in linea di principio, un sistema granulare di gestione dell'incertezza a livello di singolo servizio applicabile oltre questo caso di studio, e un percorso testato, seppur laborioso, per riconciliare l'output SRI automatizzato con la documentazione edilizia esistente. La logica di calcolo qui sviluppata è strutturata in modo indipendente dalla sua interfaccia prototipale, così da poter essere riutilizzata come modulo backend all'interno del portale Digital Building Logbook mantenuto dall'iniziativa Habitech dell'Università di Brescia nell'ambito della collaborazione tunES, un'integrazione documentata esplicitamente nel capitolo dedicato allo sviluppo tecnico di questa tesi. I protocolli di cybersicurezza e le dimensioni economiche dell'adozione di questo approccio su larga scala restano fuori dall'ambito della ricerca e sono identificati come direzioni per lavori futuri.
File allegati
File Dimensione Formato  
2026_10_Dossman_Villamizar.pdf

accessibile in internet per tutti

Descrizione: Managemnt of build enviroment thesis
Dimensione 1.85 MB
Formato Adobe PDF
1.85 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266048