How to enhance a floating Liquefied Natural Gas (LNG) facility: this is the huge question the major oil & gas companies are grappling with today, and this will be the core focus of the thesis. To tackle it, this research presents a systematic evaluation of a 2.4 MTPA offshore floating LNG facility. By integrating process simulation in Aspen HYSYS®, global optimization via Genetic Algorithm (GA) in MATLAB®, and power plant modeling in GT-PRO® and Thermoflex®, this work addresses the two primary energy consumers of an LNG plant: the cryogenic liquefaction loop and the power generation train. First, the optimization of the liquefaction unit reduces the Specific Energy Consumption (SEC) from 0.286 to 0.265 kWh/kg, by tuning the internal parameters and decoupling the compressors, and to 0.259 kWh/kg, by also refrigerant composition optimization. Finally, an overall exergy analysis shows an increase of global plant exergetic efficiency from 0.39 to 0.43. Afterwards, three power generation architectures for driving the refrigerant compressors are evaluated: aeroderivative gas turbines (Scenario 1, baseline), single combined cycle and electric motors (Scenario 2), and two combined cycles and electric motors (Scenario 3). Energetically, Scenario 2 reaches the highest product-to-fuel ratio, equal to 11.95, and up to 13.20 under optimized liquefaction conditions, versus 9.85 of Scenario 1, while Scenario 3 reaches a value of 11.15. Also, from the economic perspective, Scenario 2 stands out among the others. From a broader perspective, however, the direct-drive gas turbine configuration remains nowadays the most robust: its high intrinsic availability, compact footprint, modularity, and rapid restart capabilities outweigh the fuel-saving.

Come efficientare un impianto galleggiante di Gas Naturale Liquefatto (GNL): è questo un grande interrogativo con cui si misurano oggi le grandi compagnie di oil & gas, nonché il cuore di questa tesi. La ricerca infatti presenta una valutazione sistematica di un impianto galleggiante di GNL da 2.4 MTPA. Integrando la simulazione di processo in Aspen HYSYS®, l'ottimizzazione globale tramite algoritmo genetico in MATLAB® e la modellazione termoelettrica in GT-PRO® e Thermoflex®, questo studio esamina i due principali consumatori energetici: il ciclo di liquefazione criogenica e la sezione di generazione di potenza. L'ottimizzazione dell'unità di liquefazione riduce il consumo energetico specifico (SEC) da 0.286 a 0.265 kWh/kg, regolando i parametri interni e disaccoppiando i compressori, e fino a 0.259 kWh/kg, ottimizzando anche la composizione del refrigerante. Inoltre, l'analisi exergetica mostra un incremento dell'efficienza globale dell'impianto da 0.39 a 0.43. Successivamente, vengono confrontate tre architetture per l'azionamento dei compressori del refrigerante: turbine a gas aeroderivate (Scenario 1, caso base), un singolo ciclo combinato con accoppiamento con motori elettrici (Scenario 2) e due cicli combinati con motori elettrici (Scenario 3). Sotto il profilo energetico, lo Scenario 2 raggiunge il più alto rapporto prodotto-combustibile, pari a 11.95 e fino a 13.20 in condizioni ottimizzate, contro 9.85 dello Scenario 1 e 11.15 dello Scenario 3. Lo Scenario 2 primeggia sugli altri anche economicamente. Tuttavia, in una prospettiva operativa più ampia, la configurazione con turbogas rimane la più solida: l'elevata disponibilità, la compattezza, la modularità e la capacità di riavvio rapido superano i vantaggi in termini di risparmio economico e energetico dei complessi cicli combinati.

Energy efficiency optimization of off-shore LNG plants

Travaglia, Alice
2025/2026

Abstract

How to enhance a floating Liquefied Natural Gas (LNG) facility: this is the huge question the major oil & gas companies are grappling with today, and this will be the core focus of the thesis. To tackle it, this research presents a systematic evaluation of a 2.4 MTPA offshore floating LNG facility. By integrating process simulation in Aspen HYSYS®, global optimization via Genetic Algorithm (GA) in MATLAB®, and power plant modeling in GT-PRO® and Thermoflex®, this work addresses the two primary energy consumers of an LNG plant: the cryogenic liquefaction loop and the power generation train. First, the optimization of the liquefaction unit reduces the Specific Energy Consumption (SEC) from 0.286 to 0.265 kWh/kg, by tuning the internal parameters and decoupling the compressors, and to 0.259 kWh/kg, by also refrigerant composition optimization. Finally, an overall exergy analysis shows an increase of global plant exergetic efficiency from 0.39 to 0.43. Afterwards, three power generation architectures for driving the refrigerant compressors are evaluated: aeroderivative gas turbines (Scenario 1, baseline), single combined cycle and electric motors (Scenario 2), and two combined cycles and electric motors (Scenario 3). Energetically, Scenario 2 reaches the highest product-to-fuel ratio, equal to 11.95, and up to 13.20 under optimized liquefaction conditions, versus 9.85 of Scenario 1, while Scenario 3 reaches a value of 11.15. Also, from the economic perspective, Scenario 2 stands out among the others. From a broader perspective, however, the direct-drive gas turbine configuration remains nowadays the most robust: its high intrinsic availability, compact footprint, modularity, and rapid restart capabilities outweigh the fuel-saving.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
Come efficientare un impianto galleggiante di Gas Naturale Liquefatto (GNL): è questo un grande interrogativo con cui si misurano oggi le grandi compagnie di oil & gas, nonché il cuore di questa tesi. La ricerca infatti presenta una valutazione sistematica di un impianto galleggiante di GNL da 2.4 MTPA. Integrando la simulazione di processo in Aspen HYSYS®, l'ottimizzazione globale tramite algoritmo genetico in MATLAB® e la modellazione termoelettrica in GT-PRO® e Thermoflex®, questo studio esamina i due principali consumatori energetici: il ciclo di liquefazione criogenica e la sezione di generazione di potenza. L'ottimizzazione dell'unità di liquefazione riduce il consumo energetico specifico (SEC) da 0.286 a 0.265 kWh/kg, regolando i parametri interni e disaccoppiando i compressori, e fino a 0.259 kWh/kg, ottimizzando anche la composizione del refrigerante. Inoltre, l'analisi exergetica mostra un incremento dell'efficienza globale dell'impianto da 0.39 a 0.43. Successivamente, vengono confrontate tre architetture per l'azionamento dei compressori del refrigerante: turbine a gas aeroderivate (Scenario 1, caso base), un singolo ciclo combinato con accoppiamento con motori elettrici (Scenario 2) e due cicli combinati con motori elettrici (Scenario 3). Sotto il profilo energetico, lo Scenario 2 raggiunge il più alto rapporto prodotto-combustibile, pari a 11.95 e fino a 13.20 in condizioni ottimizzate, contro 9.85 dello Scenario 1 e 11.15 dello Scenario 3. Lo Scenario 2 primeggia sugli altri anche economicamente. Tuttavia, in una prospettiva operativa più ampia, la configurazione con turbogas rimane la più solida: l'elevata disponibilità, la compattezza, la modularità e la capacità di riavvio rapido superano i vantaggi in termini di risparmio economico e energetico dei complessi cicli combinati.
File allegati
File Dimensione Formato  
2026_10_Travaglia_Tesi_01.pdf

non accessibile

Descrizione: tesi
Dimensione 4.59 MB
Formato Adobe PDF
4.59 MB Adobe PDF   Visualizza/Apri
2026_10_Travaglia_Executive Summary_01.pdf

non accessibile

Descrizione: executive summary
Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266238